Acute Coronary Syndrome (ACS) patients with thrombocytopenia that requires percutaneous coronary intervention (PCI) have been under-represented in the major clinical trials, and there are currently no guideline recommendations on the management of this cohort. We examined the effect of
Background: Gender has been shown to affect the management and outcomes in Non-ST-segment Elevation Myocardial Infarction (NSTEMI). The aim of this study was to determine differences in the outcomes of patients diagnosed with NSTEMI and the effect gender has on these factors. Methods: This was a
BackgroundSeptal ablation (SA) is a key modality for left ventricular outflow tract gradient reduction in hypertrophic obstructive cardiomyopathy (HOCM) patients with refractory symptoms. The primary objective of our study was to evaluate post-procedural mortality, complications, length of stay (LOS), and cost of hospitalization following SA.MethodsWe queried the Nationwide Inpatient Sample (NIS) between 2005 and 2011 using the ICD9 procedure code of 37.34 for ablation of heart tissue. Only adult patients with HOCM (ICD-9-CM: 425.1) were included. Patients with any arrhythmia diagnosis or open surgical ablation procedure code were excluded. Hierarchical mixed effects models were generated in order to identify the independent multivariate predictors of outcomes.ResultsA total of 358 SAs were available for analysis. There was no reported mortality during the study period; permanent pacemaker implantation rate was 8.7%. Highest hospital volume tertile (OR, 95%CI, P- value) predicted significantly lower post-procedural complications (0.51, 0.26-0.98, P=0.04). Univariate analysis of highest versus lowest tertile of hospital volume showed significant decrease in LOS (2.6 days vs. 3.8 days, P<0.01) and non-significant decrease hospitalization costs (16,800$ vs. 19,500$, P=0.29).ConclusionsSA is a safe procedure and associated with low peri- procedural mortality rate. A higher burden of baseline comorbidities is associated with worse outcomes while higher annual hospital volume is associated with lower rate of post-procedural complications, length of stay, and cost of care following SA.
Introduction: There are few data in the literature regarding impact of annual hospital volume on outcomes such as mortality and length of stay (LOS) post-LVAD implantation.Methods: We queried the nationwide inpatient sample from 2008 to 2011 using International Classification of Diseases, 9th Revision procedure code 37.66. We included patients >= 1.8 years without primary diagnosis of orthotopic heart transplant. Annual volume of LVAD implantation was computed for each hospital. Multivariable hierarchical mixed effect logistic regression models were used to determine predictors of in-hospital mortality and LOS.Results: There were 1749 LVAD implants from 2008 to 2011; patients had a mean age of 55.4 years, and 23% were female. In-hospital mortality decreased from 20.9% in the first tertile (1-22 LVADs/y) to 13.7% in the third tertile (>= 35 LVADs/y) of hospital volume. Median LOS decreased from 34 days in the first tertile to 28 days in third tertile of hospital volume. The adjusted odds ratios of the highest tertile of hospital volume in predicting in-hospital mortality and LOS were 0.41 (0.26-0.64, P < .001) and 0.41 (0.23-0.73, P = .003), respectively. Restricted cubic spline analysis showed that a volume threshold of >20 LVADs/year was associated with favorable mortality rates of <10%.Conclusions: High annual LVAD volume is associated with significantly decreased in-hospital mortality and LOS after LVAD implantation. Center experience is an important determinant of optimal patient outcomes.
We studied the trends and predictors of drug eluting stent (DES) utilization from 2006 to 2011 to further expound the inter‐hospital variability in their utilization.
Fibrinolytic therapy is still widely used in patients with STEMI. However, transfer for angiography and revascularization within 3-24 hours is currently recommended as part of a pharmacoinvasive strategy. We used Nationwide Inpatient Sample databases from 2008 to 2012 to identify all patients’
Background: Contemporary outcome data regarding effects of atherectomy in lower extremity arterial revascularization is lacking. Methods: We queried HCUP’s Nationwide Inpatient Sample (NIS) for 2012 using the appropriate primary ICD 9-CM diagnostic code for peripheral vascular disease and procedural codes 39.90 (bare metal stent - BMS), 00.55 (drug eluting stent - DES), 17.56 (peripheral artherectomy) and 39.50 for angioplasty. Only procedures performed in patients >= 18 years were included. Hierarchical mixed effects logistic regression models were generated to evaluate multivariate predictors of outcomes. Results: In total 13,206 (weighted: 66,030) lower extremity arterial revascularization were analyzed (65.5% white, 56.2% Male & 97.4% angioplasty). Atherectomy utilization (23.2%) was associated with significant reduction in amputation (11.5% vs 13.4%), any complications (13.2% vs 16.3%) and in hospital morality (0.8% vs 1.4%) compared to no atherectomy group (p < 0.001). Multivariate analysis showed similar results with decrease amputation (OR, 95% CI; p - value) (0.83, 0.71 - 0.97, p = 0.02) and in hospital mortality/any complication (0.79, 0.69 - 0.90, p = 0.001) with atherectomy (similar results were observed with propensity score matching). “Atherectomy only” was utilized only in 2.3%. post-hoc analysis also shows better outcomes when atherectomy was used with either angioplasty or stenting (figure a & b). subgroup multivariate analysis shows significant reduction in amputation when atherectomy was utilized in chronic limb ischemia (0.74, 0.59 - 0.93, p = 0.01) and with angioplasty (0.72, 0.60 - 0.87, p = 0.001) and trend towards advantage while used along with stents but not reaching statistical significant. Conclusion: Lower extremity atherectomy utilization was associated with significant reduction in amputation and overall complication. We observed better outcomes when atherectomy was used in conjunction with angioplasty.
Background. Left ventricular assist devices (LVADs) have shown survival benefit in end-stage heart failure patients. LVAD technology has evolved considerably with the development of continuous-flow devices.Methods. The Nationwide Inpatient Sample was queried from 2005 to 2011 using International Classification of Diseases, 9th Edition procedure code 37.66, Insertion of Implantable Heart System, in any procedure field. Patients with primary diagnosis of orthotopic heart transplant or use of temporary mechanical circulatory support devices were excluded. Procedural complications were identified using International Classification of Diseases, 9th Edition codes and patient safety indicators. Cochran-Armitage and Cuzick tests for trend were used to identify time trends for categorical and continuous variables, respectively.Results. There were 2,038 LVAD implantations from 2005 to 2011. LVAD use increased from 127 procedures in 2005 to 506 procedures in 2011, and in-hospital mortality declined from 47.2% to 12.7% (p < 0.001), with sharp inflection points in the year 2008. Average length of stay decreased from 44 days in the pulsatile flow era (2005 to 2007) to 36 days in the continuous-flow era (2008 to 2011). Cost of hospitalization increased from $194,380 in 2005 to $234,808 in 2011 but remained constant from 2008 to 2011. There was a trend of increased incidence of major bleeding and thromboembolism and decreased incidence of infectious and iatrogenic cardiac complications in the continuous-flow era.Conclusions. LVAD use has increased and in-hospital mortality and LOS after LVAD implantation have declined. These changes coincide with United States Food and Drug Administration (FDA) approval of continuous flow devices in 2008. (C) 2016 by The Society of Thoracic Surgeons
Despite the valuable role of intravascular. ultrasound (IVUS) guidance in percutaneous coronary interventions (PCIs), its impact on clinical outcomes remains debatable. The aim of the present study was to compare the outcomes of PCIs guided by IVUS versus angiography in the contemporary era on inhospital outcomes in an unrestricted large, nationwide patient population. Data were obtained from the Nationwide Inpatient Sample from 2008 to 2011. Hierarchical mixed-effects logistic regression models were used for categorical dependent variables like inhospital mortality, and hierarchical mixed-effects linear regression models were used for continuous dependent variables like length of hospital stay and cost of hospitalization. A total of 401,571 PCIs were identified, of which 377,096 were angiography guided and 24,475 (weighted n = 119,102) used IVUS. In a multivariate model, significant predictors of higher mortality were increasing age, female gender, higher baseline co-morbidity burden, presence of acute myocardial infarction, shock, weekend and emergent admission, or occurrence of any complication during hospitalization. Significant predictors of reduced mortality were the use of IVUS guidance (odds ratio 0.65, 95% confidence interval 0.52 to 0.83; p <0.001) for PCI and higher hospital volumes (third and fourth quartiles). The use of IVUS was also associated with reduced inhospital mortality in subgroup of patients with acute myocardial infarction and/or shock and those with a higher co-morbidity burden (Charlson's co-morbidity index >= 2). In one of the largest studies on IVUS-guided PCIs in the drug-eluting stent era, we demonstrate that IVUS guidance is associated with reduced inhospital mortality, similar length of hospital stay, and increased cost of care and vascular complications compared with conventional angiography-guided PCIs. (C) 2015 Elsevier Inc. All rights reserved.
The comparative data for angioplasty and stenting for treatment of peripheral arterial disease are largely limited to technical factors such as patency rates with sparse data on clinical outcomes like mortality, postprocedural complications, and amputation. The study cohort was derived from the Healthcare Cost and Utilization Project Nationwide Inpatient Sample database from 2006 to 2011. Peripheral endovascular interventions were identified using appropriate International Classification of Diseases, Ninth Revision (ICD-9) Diagnostic and procedural codes. Two-level hierarchical multivariate mixed models were created. The primary outcome includes inhospital mortality, and secondary outcome was a composite of inhospital mortality and postprocedural complications. Amputation was a separate outcome. Hospitalization costs were also assessed. Endovascular stenting (odds ratio, 95% confidence interval, p value) was independently predictive of lower composite end point of inhospital mortality and. postprocedural complications compared with. angioplasty alone (0.96, 0.91 to 0.99, 0.025) and lower amputation rates (0.56, 0.53 to 0.60, <0.001) with no significant difference in terms of inhospital mortality alone. Multivariate analysis also revealed stenting to be predictive of higher hospitalization costs ($1,516, 95% confidence interval 1,082 to 1,950, p <0.001) compared with angioplasty. In conclusion, endovascular stenting is associated with a lower rate of postprocedural complications, lower amputation rates, and only minimal increase in hospitalization costs compared with angioplasty alone. (C) 2015 Elsevier Inc. All rights reserved.
OBJECTIVE:Prior studies have described a negative relationship between influenza vaccination and recurrence of cardiovascular (CV) events. However, due to lack of any prior studies, we evaluated and attempted to define the relationship between non-influenza vaccines and CV mortality.METHODS:We used the National Health and Nutrition Examination Survey III (NHANES III-1988-1994, n = 19,215) and Continuous NHANES (1999-2004, n > 17,000), which includes oral surveys and general examination. It was designed to assess the demographic, socioeconomic, dietary, and overall health status of a nationally representative sample in non-institutionalized patients from all 50 states in the USA. Cox proportional hazard regression modeling was used to calculate the hazard ratio of CV mortality, and multivariate models were built for the individual seropositive vaccination titers as well as after creating a combined vaccination variable.RESULTS:A total of >35,000 subjects (>18 years old) have been identified for analysis. Multivariate analysis from NHANES III and continuous NHANES did not show any influence of individual seroprotective titers of routine vaccinations on CV mortality. The combined effect of vaccination in NHANES III data did not show any protective effect of three or more positive vaccination titers (odds ratio = 0.94, p = 0.6) or all four positive vaccination titers (odds ratio = 0.93, p = 0.6) with two or less positive vaccination titers as the referent group.CONCLUSION:Effect on non-influenza vaccinations in preventing CV mortality seems to be unclear.
Although prior studies have demonstrated favorable outcomes with intravascular ultrasound(IVUS) in coronary interventions, there is lack of data on the impact of IVUS utilization in peripheral vascular interventions. We queried the HCUP's Nationwide Inpatient Sample (NIS) between 2006 - 2011 using
There is lack of data on the impact of hospital volume on the length of stay (LOS) and cost of hospitalization following peripheral vascular intervention. We queried the Healthcare Cost and Utilization Project’s Nationwide Inpatient Sample (NIS) between 2000-2011 using the, ICD-9 for peripheral
Transcatheter aortic valve implantation (TAVI) is associated with a significant learning curve. There is paucity of data regarding the effect of hospital volume on outcomes after TAVI. This is a cross-sectional study based on Healthcare Cost and Utilization Project's Nationwide Inpatient Sample database of 2012. Subjects were identified by International Classification of Diseases, Ninth Revision, Clinical Modification procedure codes, 35.05 (Trans-femoral/Trans-aortic Replacement of Aortic Valve) and 35.06 (Trans-apical Replacement of Aortic Valve). Annual hospital TAVI volumes were calculated using unique identification numbers and then divided into quartiles. Multivariate logistic regression models were created. The primary outcome was inhospital mortality; secondary outcome was a composite of inhospital mortality and periprocedural complications. Length of stay (LOS) and cost of hospitalization were assessed. The study included 1,481 TAVIs (weighted n = 7,405). Overall inhospital mortality rate was 5.1%, postprocedural complication rate was 43.4%, median LOS was 6 days, and median cost of hospitalization was $51,975. Inhospital mortality rates decreased with increasing hospital TAVI volume with a rate of 6.4% for lowest volume hospitals (first quartile), 5.9% (second quartile), 5.2% (third quartile), and 2.8% for the highest volume TAVI hospitals (fourth quartile). Complication rates were significantly higher in hospitals with the lowest volume quartile (48.5%) compared to hospitals in the second (44.2%), third (39.7%), and fourth (41.5%) quartiles (p <0.001). Increasing hospital volume was independently predictive of shorter LOS and lower hospitalization costs. In conclusion, higher annual hospital volumes are significantly predictive of reduced postprocedural mortality, complications, shorter LOS, and lower hospitalization costs after TAVI. (C) 2015 Elsevier Inc. All rights reserved.
The role of catheter-directed thrombolysis in the treatment of pulmonary embolism is controversial, and real world outcomes are unknown. We used Nationwide Inpatient Sample database from 2000 to 2012 to identify all patients aged ≥ 18 years with PE. We compared patients treated with CDT against
Introduction: The data regarding use of different Mechanical Circulatory Support (MCS) devices in TAVR is limited. The present study was performed to analyze the complications and outcomes of different MCS in TAVR. Methods: The subjects under study were obtained from Nationwide Inpatient Sample (NIS) for the years 2011-12 using ICD-9-CM procedure codes for TAVR and MCS. The use of MCS was divided into Intra-aortic balloon pump (IABP), percutaneous ventricular assist devices (PVADs) including Impella and TandemHeart, Extracorporeal membrane oxygenation (ECMO) and percutaneous cardiopulmonary support and cardiopulmonary bypass (CBP) using ICD-9-CM codes. The incidence of in-hospital mortality and occurrence of procedure related complications were analyzed. Results: Out of total 1794 TAVR procedures, MCS was utilized in 190 (10.6%) procedures. CBP was the most commonly utilized 136 (71.6%) followed by IABP 36 (18.9%), ECMO 14 (7.4%) and 4 (2.1%). In-hospital mortality was highest with use of IABP (36.6%), followed by ECMO (14.3%), CBP (9.6%) and PVAD (0%) with p-value <0.01. The incidence of complications was similar in IABP and PVAD (100% each) followed by ECMO (85.7%) and CBP (59.4%) with p-value <0.01. Conclusion: Being retrospective in design, the present study has no information regarding indications and individual patient related variables in which each of the MCS devices used. Overall, CBP was observed as the most extensive used MCS modality with less mortality (9.6%) and least complications (59.4%).