Inter-individual variability in muscle responses to mechanical stress during exercise is poorly understood. Therefore, new cell culture scaffolds are needed to gain deeper insights into the cellular mechanisms underlying the influence of mechanical stress on human myogenic progenitor cells behavior. To this end, we propose the first in vitro model involving uniaxial mechanical stress applied to aligned human primary muscle-derived cells, employing a biocompatible organic-inorganic photostructurable hybrid material (OIPHM) covalently attached to a stretchable PDMS support. Using a laser printing technique with an additive photolithographic process, we optimally micropatterned the PDMS support to create longitudinal microgrooves, achieving well-aligned muscle fibers without significantly affecting their diameter. This support was biofunctionalized with peptide sequences from the ECM, which interact with cellular adhesion receptors and prevent myotube detachment induced by stretching. X-ray photoelectron spectroscopy (XPS) of biofunctionalized PDMS with RGD-derived peptide deposition revealed a significant increase in nitrogen compared to silicon, associated with the presence of a 380 nm thick layer measured by atomic force microscopy (AFM). Upon cell culture, we observed that functionalization with an RGD peptide had a beneficial impact on cell fusion rate and myotube area compared to bare PDMS. At the initiation of the stretching protocol, we observed a three-fold rapid and transient increase in RNA expression for the mechanosensitive ion channel protein piezo and a decrease in the ratio of nuclei expressing myogenin relative to the total nuclei count (43 ± 16% vs. 6 ± 6%, p < 0.01). Compared to day 0 of differentiation, stretching the myotubes induced MHC and Titin colocalization (0.66 ± 0.13 vs. 0.93 ± 0.05, p < 0.01), favoring sarcomere organization and maturation. In this study, we propose and validate an optimized protocol for culturing human primary muscle-derived cells, allowing standardized uniaxial mechanical stress with a biocompatible OIPHM covalently linked to PDMS biofunctionalized with an ECM-derived peptide, to better characterize the behavior of myogenic progenitor cells under mechanical stress in future studies.
Background Growing evidence associates organ dysfunction(s) with impaired metabolism in sepsis. Recent research has increased our understanding of the role of substrate utilization and mitochondrial dysfunction in the pathophysiology of sepsis-related organ dysfunction. The purpose of this review is to present this evidence as a coherent whole and to highlight future research directions. Main text Sepsis is characterized by systemic and organ-specific changes in metabolism. Alterations of oxygen consumption, increased levels of circulating substrates, impaired glucose and lipid oxidation, and mitochondrial dysfunction are all associated with organ dysfunction and poor outcomes in both animal models and patients. The pathophysiological relevance of bioenergetics and metabolism in the specific examples of sepsis-related immunodeficiency, cerebral dysfunction, cardiomyopathy, acute kidney injury and diaphragmatic failure is also described. Conclusions Recent understandings in substrate utilization and mitochondrial dysfunction may pave the way for new diagnostic and therapeutic approaches. These findings could help physicians to identify distinct subgroups of sepsis and to develop personalized treatment strategies. Implications for their use as bioenergetic targets to identify metabolism- and mitochondria-targeted treatments need to be evaluated in future studies.
Rationale: Prolonged mechanical ventilation is often associated with either a decrease (known atrophy) or an increase (supposed injury) in diaphragmatic thickness. Shear wave elastography is a noninvasive technique that measures shear modulus, a surrogate of tissue stiffness and mechanical properties. Objectives: To describe changes in shear modulus (SM) during the ICU stay and the relationship with alterations in muscle thickness. To perform a comprehensive ultrasound-based characterization of histological and force production changes occurring in the diaphragm. Methods: Translational study using critically ill patients and mechanically ventilated piglets. Serial ultrasound examination of the diaphragm collecting thickness and SM was performed in both patients and piglets. Transdiaphragmatic pressure and diaphragmatic biopsies were collected in piglets. Measurements and Main Results: We enrolled 102 patients, 88 of whom were invasively mechanically ventilated. At baseline, SM was 14.3 ± 4.3 kPa and diaphragm end-expiratory thickness was 2.0 ± 0.5 mm. Decrease or increase by more than 10% from baseline was reported in 86% of the patients for thickness and in 92% of the patients for SM. An increase in diaphragmatic thickness during the stay was associated with a decrease in SM (β = -9.34 ± 4.41; P = 0.03) after multivariable analysis. In the piglet sample, a decrease in SM over 3 days of mechanical ventilation was associated with loss of force production, slow and fast fiber atrophy, and increased lipid droplets accumulation. Conclusions: Increases in diaphragm thickness during critical illness is associated with decreased tissue stiffness as demonstrated by shear wave ultrasound elastography, consistent with the development of muscle injury and weakness. Clinical trial registered with www.clinicaltrials.gov (NCT03550222).
In the publication of this article [1], there was an error in the Family Name of one of the authors. This has now been updated in the original article.