We present the results of high-voltage collinear laser spectroscopy measurements on the 5 ppm relative uncertainty level using a pump and probe scheme at the 4s S-2(1/2) -> 4p P-2(3/2) transition of Ca-40(+) involving the 3d D-2(5/2) metastable state. With two-stage laser interaction and a reference measurement we can eliminate systematic effects such as differences in the contact potentials due to different electrode materials and thermoelectric voltages, and the unknown starting potential of the ions in the ion source. Voltage measurements were performed between -5 kV and -19 kV and parallel measurements with stable high-voltage dividers calibrated to 5 ppm relative uncertainty were used as a reference. Our measurements are compatible with the uncertainty limits of the high-voltage dividers and demonstrate an unprecedented (factor of 20) increase in the precision of direct laser-based high-voltage measurements.
We present results of laser spectroscopic high voltage measurements on the 5 ppm relative uncertainty level using a pump and probe scheme on Ca + ions. With the two-stage laser interaction and with a reference measurement we can eliminate systematic effects like differences in contact potentials of electrode materials, thermo-electric voltages, and the unknown starting potential of the ions in the ion source. Our measurements are compatible with the 5 ppm precision limits of the high voltage dividers used for comparison and demonstrate an unprecedented increase in the accuracy of laser-based high voltage measurements by a factor of 20.
Many physics experiments depend on accurate high-voltage measurements to determine for example the exact retardation potential of an electron spectrometer as in the KATRIN experiment or the acceleration voltage of the ions at ISOL facilities. Until now only precision high-voltage dividers can be used to measure voltages up to 65 kV with an accuracy of 1 ppm. However, these dividers need frequent calibration and cross-checking and the direct traceability is not given. In this article we will describe the status of an experiment which aims to measure high voltages using collinear laser spectroscopy and which has the potential to provide a high-voltage standard and hence, a calibration source for precision high-voltage dividers on the 1 ppm level.
High magnetic fields (>1 T) are measured by NMR magnetometers with unrivaled precision if the precessing spin sample provides long coherence times. The longest coherence times are found in diluted 3He samples, which can be hyperpolarized for sufficient signal strength. In order to have minimal influence on the homogeneity and value of the measured magnetic field, the optimal container for the 3He should be a perfect sphere. A fused silica sphere with an inner diameter of 8 mm and an outer diameter of 12 mm was made from two hemispheres by diffusion bonding leaving only a small hole for cleaning and evacuation. This hole was closed in vacuum by a CO2 laser and the inner volume was filled with a few mbars of 3He via wall permeation. NMR-measurements on such a sample had coherence times of 5 min. While the hemispheres were produced with <1 μm deviation from sphericity, the bonding left a step of ca. 50 μm at maximum. The influence of such a mismatch, its orientation, and the immediate environment of the sample is analyzed by FEM-simulations and discussed in view of coherence times and absolute field measurements.
Purpose MRI of lung airspaces using gases with MR‐active nuclei ( 3 He, 129 Xe, and 19 F) is an important area of research in pulmonary imaging. The volume‐controlled administration of gas mixtures is important for obtaining quantitative information from MR images. State‐of‐the‐art gas administration using plastic bags (PBs) does not allow for a precise determination of both the volume and timing of a 3 He bolus. Methods A novel application unit (AU) was built according to the requirements of the German medical devices law. Integrated spirometers enable the monitoring of the inhaled gas flow. The device is particularly suited for hyperpolarized (HP) gases (e.g., storage and administration with minimal HP losses). The setup was tested in a clinical trial (n = 10 healthy volunteers) according to the German medicinal products law using static and dynamic ventilation HP‐ 3 He MRI. Results The required specifications for the AU were successfully realized . Compared to PB‐administration, better reproducibility of gas intrapulmonary distribution was observed when using the AU for both static and dynamic ventilation imaging. Conclusion The new AU meets the special requirements for HP gases, which are storage and administration with minimal losses. Our data suggest that gas AU‐administration is superior to manual modes for determining the key parameters of dynamic ventilation measurements. Magn Reson Med 74:884–893, 2015. © 2014 Wiley Periodicals, Inc.
We describe a 3He magnetometer capable to measure high magnetic fields (B > 0.1 Tesla) with a relative accuracy of better than 10^-12. Our approach is based on the measurement of the free induction decay of gaseous, nuclear spin polarized 3He following a resonant radio frequency pulse excitation. The measurement sensitivity can be attributed to the long coherent spin precession time T2* being of order minutes which is achieved for spherical sample cells in the regime of motional narrowing where the disturbing influence of field inhomogeneities is strongly suppressed. The 3He gas is spin polarized in-situ using a new, non-standard variant of the metastability exchange optical pumping. We show that miniaturization helps to increase T2* further and that the measurement sensitivity is not significantly affected by temporal field fluctuations of order 10^-4.
The KArlsruhe TRItium Neutrino (KATRIN) experiment is a next-generation, large-scale tritium β-decay experiment to determine the neutrino mass by investigating the kinematics of tritium β-decay with a sensitivity of 200 meV/c2 using the MAC-E filter technique. In order to reach this sensitivity a low background level of 10−2 counts per second (cps) is required. A major background concern in MAC-E filters is the presence of Penning traps. A Penning trap is a special configuration of electromagnetic fields that allows the storage of electrically charged particles. This paper describes the mechanism of Penning discharges and the corresponding measurements performed at the test setup of the KATRIN pre-spectrometer. These investigations led to the conclusion that the observed electric breakdown, strong discharges and extremely large background rates were due to discharges caused by Penning traps located at both ends of the pre-spectrometer. Furthermore, the paper describes the design of a new set of electrodes (modified ground electrodes and new ``anti-Penning'' electrodes) to successfully remove these traps. After the installation of these electrodes in the pre-spectrometer, the measurements confirmed that the strong Penning discharges disappeared. The experience gained from the pre-spectrometer was used to design the electrode system of the main spectrometer. Recent measurements with the main spectrometer showed no indications of Penning trap related backgrounds.
The KATRIN experiment aims at the direct model-independent determination of the average electron neutrino mass via the measurement of the endpoint region of the tritium beta decay spectrum. The electron spectrometer of the MAC-E filter type is used, requiring very high stability of the electric filtering potential. This work proves the feasibility of implanted 83Rb/83mKr calibration electron sources which will be utilised in the additional monitor spectrometer sharing the high voltage with the main spectrometer of KATRIN. The source employs conversion electrons of 83mKr which is continuously generated by 83Rb. The K–32 conversion line (kinetic energy of 17.8 keV, natural line width of 2.7 eV) is shown to fulfill the KATRIN requirement of the relative energy stability of ±1.6 ppm/month. The sources will serve as a standard tool for continuous monitoring of KATRIN's energy scale stability with sub-ppm precision. They may also be used in other applications where the precise conversion lines can be separated from the low energy spectrum caused by the electron inelastic scattering in the substrate.
Polarization of 3He gas by means of optical pumping is well known since the early 1960s with first applications in fundamental physics. Some thirty years later it was discovered, that one can use hyperpolarized 3He as contrast agent for magnetic resonance imaging of the lung. The wide interest in this new method made it necessary to find ways of polarizing 3He in large quantities with high polarization degrees. A high performance polarizing facility has been developed at the University of Mainz, designed for centralized production of hyperpolarized 3He gas. We present the Mainz concept as well as some examples of numerous applications of spin polarized 3He in fundamental research and medical applications.
The presently lowest limit for the mass of the electron neutrino is m ν < 2.2 eV/c 2 (95 %C.L.) derived from measurements at Mainz. A proposed experiment KATRIN should improve this neutrino mass sensitivity by one order of magnitude to check the cosmological relevance of neutrino masses and to distinguish between hierarchical and degenerate neutrino mass models.
Experiments with polarized He-3 targets at the Mainz Microtron (MAMI) involve double polarized photoabsorption or the extraction of the electric form factor of the neutron G(e,n) via electron scattering, respectively. Polarized He-3 with an initial polarization of up to 70% at the experimental areas is provided by a polarizer based on the principle of metastability exchange optical pumping (MEOP). In this article both target setups for the photon- and the electron beamlines will be described and a status of the data analysis will be given.
Photo-absorption of γ-rays in thin Al, Co, Ti, and Mo convertors was examined with the aim to produce quasi monoenergetic photoelectrons having an energy spread of 0.5-4.7eV about mean kinetic energies at discrete values between 18632 and 80321eV. The photoelectron rates were estimated for commercial photon sources of (241)Am, (119m)Sn, (125m)Te and (109)Cd with activities of 0.55-3.7GBq. Photoelectrons ejected by (241)Am γ- and X-rays from Co convertors were measured with two different electron spectrometers and obtained energy spectra were compared with Monte Carlo predictions.
Hyperpolarized (HP) noble gases (3He,129Xe) are used for MR-imaging of the lung. In the majority of case the HP gas is filled in Tedlarbags and directly inhaled by the patients. Starting from an earlier pilot device, an administration unit was built respectively to the Medical Devices Law to administer patients HP noble gas boli in defined quantities and at a predefined time during inspiration with high reproducibility and reliability without reducing MR-quality. The patient's airflows are monitored and recorded. It is possible to use gas admixtures, measure the polarization on-line and collect the exhaled gas for later recycling. The first images with healthy volunteers were taken with this setup in a clinical study. Current results will be presented.
A new high precision voltage divider has been built for monitoring the analysing potential of the KATRIN main spectrometer. In addition a condensed Kr-83m calibration source has been set up at the modified 1 eV resolving Mainz spectrometer, our measurements show that energy calibration and monitoring for KATRIN is feasible at the few ppm level.
A polarized 3He target has been installed for the first time inside the 4π Crystal Ball detector at the tagged photon beam of the MAinz MIcrotron (MAMI). It has been demonstrated that the system works reliably and that the polarization losses during handling of the polarized gas are under control. Initial polarization values up to 70% and total relaxation times up to 20h could be obtained during a first test beam time devoted to the measurement of the double polarized photoabsorption cross-section in the Δ(1232) baryon resonance region.
In this paper we present concepts, developed to construct a compact 3He polarizing facility as well as first results of their realization. The apparatus, which is currently in the state of construction, is based on the method of metastability exchange optical pumping (MEOP). Contrary to the present apparatus at the university of Mainz, which serves as central polarizing facility, the compact polarizer is designed to serve as local polarizing facility in both basic research and medical application. With the new polarizer we aim to reach polarization degrees of P > 65% at a flux of several standard liters per hour.
We have developed the means to recycle (3) He exhaled by patients after imaging the lungs using magnetic resonance of hyperpolarized (3) He. The exhaled gas is collected in a helium leak proof bag and further compressed into a steel bottle. The collected gas contains about 1-2% of (3) He, depending on the amount administered and the number of breaths collected to wash out the (3) He gas from the lungs. (3) He is separated from the exhaled air using zeolite molecular sieve adsorbent at 77 K followed by a cold head at 8 K. Residual gaseous impurities are finally absorbed by a commercial nonevaporative getter. The recycled (3) He gas features high purity, which is required for repolarization by metastability exchange optical pumping. At present, we achieve a collection efficiency of 80-84% for exhaled gas from healthy volunteers and cryogenic separation efficiency of 95%.
Photoabsorption of nuclear gamma-rays in thin metallic convertors was examined with the aim to produce monoenergetic photoelectrons of kinetic energy around 18.6 keV and natural width of about 1 eV. Calculations were carried out for commercial photon sources of 241Am (1.1 GBq) and 119mSn (0.5 GBq) irradiating Co and Ti convertors. Photoelectrons ejected by 241Am gamma- and X-rays from Co convertors of various thickness were measured with two electrostatic spectrometers.
We present novel types of permanently magnetized as well as current powered boxes built from soft-ferromagnetic materials. They provide shielded magnetic fields which are homogeneous within a large fraction of the enclosed volume, thus minimizing size, weight, and costs. For the permanently magnetized solutions, homogenization is achieved either by an optimized distribution of the permanent field sources or by jacketing the field with a soft-ferromagnetic cylindrical shell which is magnetized in parallel to the enclosed field. The latter principle may be applied up to fields of about 0.1T. With fields of about 1mT, such boxes are being used for shipping spin-polarized (3)He worldwide for MRI purposes. For current powered boxes, we present concepts and realizations of uniaxial and tri-axial shielded magnetic fields which are homogeneous on the level of 10(-4) within the entire shielded volume. This is achieved by inserting tightly fitting solenoids into a box from soft-magnetic material. The flexible tri-axial solution suits in particular laboratory applications, e.g. for establishing a spin quantization axis.