Background and Purpose The purpose of this study is to evaluate the feasibility of using 3-dimensional (3D) ultra-short echo time (UTE) radial imaging method for measurement of the permeability of the blood-brain barrier (BBB) to gadolinium-based contrast agent. In this study, we propose to use the golden-angle radial sparse parallel (GRASP) method with 3D center-out trajectories for UTE, hence named as 3D UTE-GRASP. We first examined the feasibility of using 3D UTE-GRASP dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) for differentiating subtle BBB disruptions induced by focused ultrasound (FUS). Then, we examined the BBB permeability changes in Alzheimer's disease (AD) pathology using Alzheimer's disease transgenic mice (5xFAD) at different ages. Methods For FUS experiments, we used four Sprague Dawley rats at similar ages where we compared BBB permeability of each rat receiving the FUS sonication with different acoustic power (0.4-1.0 MPa). For AD transgenic mice experiments, we included three 5xFAD mice (6, 12, and 16 months old) and three wild-type mice (4, 8, and 12 months old). Results The result from FUS experiments showed a progressive increase in BBB permeability with increase of acoustic power (p < .05), demonstrating the sensitivity of DCE-MRI method for detecting subtle changes in BBB disruption. Our AD transgenic mice experiments suggest an early BBB disruption in 5xFAD mice, which is further impaired with aging. Conclusion The results in this study substantiate the feasibility of using the proposed 3D UTE-GRASP method for detecting subtle BBB permeability changes expected in neurodegenerative diseases, such as AD.
This study utilized sub-millimeter 3T gradient echo MRI of the brainstem ex vivo to obtain a magnetic susceptibility map (QSM). ROIs of both deep brain nuclei and myelinated fiber tracts were chosen and quantified from QSM obtained from MRI field. The ex vivo specimens were then stained with Luxol Fast Blue and the resultant absorbance of the ROIs were compared to QSM. A strong linear correlation was observed (R 2 = 0.897, p = 0.0041).
BackgroundThe development of materials with tailored signal intensity in MR imaging is critically important both for the reduction of signal from non-tissue hardware, as well as for the construction of tissue-mimicking phantoms. Silicone-based phantoms are becoming more popular due to their structural stability, stretchability, longer shelf life, and ease of handling, as well as for their application in dynamic imaging of physiology in motion. Moreover, silicone can be also used for the design of stretchable receive radio-frequency (RF) coils. PurposeFabrication of materials with tailored signal intensity for MRI requires knowledge of precise T-1 and T-2 relaxation times of the materials used. In order to increase the range of possible relaxation times, silicone materials can be doped with gadolinium (Gd). In this work, we aim to systematically evaluate relaxation properties of Gd-doped silicone material at a broad range of Gd concentrations and at three clinically relevant magnetic field strengths (1.5 T, 3 T, and 7 T). We apply the findings for rendering silicone substrates of stretchable receive RF coils less visible in MRI. Moreover, we demonstrate early stage proof-of-concept applicability in tissue-mimicking phantom development. Materials and MethodsTen samples of pure and Gd-doped Ecoflex silicone polymer samples were prepared with various Gd volume ratios ranging from 1:5000 to 1:10, and studied using 1.5 T and 3 T clinical and 7 T preclinical scanners. T-1 and T-2 relaxation times of each sample were derived by fitting the data to Bloch signal intensity equations. A receive coil made from Gd-doped Ecoflex silicone polymer was fabricated and evaluated in vitro at 3 T. ResultsWith the addition of a Gd-based contrast agent, it is possible to significantly change T-2 relaxation times of Ecoflex silicone polymer (from 213 ms to 20 ms at 1.5 T; from 135 ms to 17 ms at 3 T; and from 111.4 ms to 17.2 ms at 7 T). T-1 relaxation time is less affected by the introduction of the contrast agent (changes from 608 ms to 579 ms; from 802.5 ms to 713 ms at 3 T; from 1276 ms to 979 ms at 7 T). First results also indicate that liver, pancreas, and white matter tissues can potentially be closely mimicked using this phantom preparation technique. Gd-doping reduces the appearance of the silicone-based coil substrate during the MR scan by up to 81%. ConclusionsGd-based contrast agents can be effectively used to create Ecoflex silicone polymer-based phantoms with tailored T-2 relaxation properties. The relative low cost, ease of preparation, stretchability, mechanical stability, and long shelf life of Ecoflex silicone polymer all make it a good candidate for "MR invisible" coil development and bears promise for tissue-mimicking phantom development applicability.
An otherwise healthy two-month-old female C57BL/6J mouse presented with a left-sided head tilt. Differential diagnoses included idiopathic necrotizing arteritis, bacterial otitis media/interna (Pasteurella pneumotropica, Pseudomonas aeruginosa, Streptococcus sp., Mycoplasma pulmonis and Burkholderia gladioli), encephalitis, an abscess, neoplasia, a congenital malformation and an accidental or iatrogenic head trauma. Magnetic resonance imaging (MRI) revealed a large space-occupying right olfactory lobe intra-axial lesion with severe secondary left-sided subfalcine herniation. Following imaging, the animal was euthanized due to poor prognosis. Histopathologic examination revealed a unilateral, full-thickness bone defect at the base of the cribriform plate and nasal conchae dysplasia, resulting in the herniation of the olfactory bulb into the nasal cavity. There was also a left midline-shift of the frontal cortex and moderate catarrhal sinusitis in the left mandibular sinus. The MRI and histopathologic changes are consistent with a congenital malformation of the nasal cavity and frontal aspect of the skull known as an ethmoidal meningoencephalocele. Encephaloceles are rare abnormalities caused by herniation of contents of the brain through a defect in the skull which occur due to disruption of the neural tube closure at the level anterior neuropore or secondary to trauma, surgical complications, cleft palate or increased intracranial pressure. The etiology is incompletely understood but hypotheses include genetics, vitamin deficiency, teratogens, infectious agents and environmental factors. Ethmoidal encephaloceles have been reported in multiple species including humans but have not been reported previously in mice. There are multiple models for spontaneous and induced craniofacial malformation in mice, but none described for ethmoidal encephaloceles.
Vascular perturbations and cerebral hypometabolism are emerging as important components of Alzheimer's disease (AD). While various in vivo imaging modalities have been designed to detect changes of cerebral perfusion and metabolism in AD patients and animal models, study results were often heterogenous with respect to imaging techniques and animal models. We therefore evaluated cerebral perfusion and glucose metabolism of two popular transgenic AD mouse strains, TgCRND8 and 5xFAD, at 7 and 12 months-of-age under identical conditions and analyzed possible molecular mechanisms underlying heterogeneous cerebrovascular phenotypes. Results revealed disparate findings in these two strains, displaying important aspects of AD progression. TgCRND8 mice showed significantly decreased cerebral blood flow and glucose metabolism with unchanged cerebral blood volume (CBV) at 12 months-of-age whereas 5xFAD mice showed unaltered glucose metabolism with significant increase in CBV at 12 months-of-age and a biphasic pattern of early hypoperfusion followed by a rebound to normal cerebral blood flow in late disease. Finally, immunoblotting assays suggested that VEGF dependent vascular tone change may restore normoperfusion and increase CBV in 5xFAD.
BackgroundHypoxic-ischemic encephalopathy (HIE) is a major cause of neonatal morbidity and mortality. Therapeutic hypothermia (TH) is the only available intervention, but neuroprotection is incomplete and variable. Seizures are common in infants with HIE undergoing TH and may worsen outcome. Phenobarbital (PB) is sometimes added, although use of prophylactic PB is controversial in the neonate. We hypothesize that prophylactic PB will not reduce, and may enhance, the neuroprotective effects of TH on brain injury and motor outcomes in the postnatal day 10 (P10) hypoxic-ischemic (HI) rat.MethodsP10 rat pups were subjected to unilateral HI and 4 h recovery with: normothermia (N); hypothermia (TH); and hypothermia with phenobarbital (TH+PB). Brain damage was assessed longitudinally at 24 h and 2 weeks using brain magnetic resonance imaging and 12 weeks using histochemical analysis. Motor function was assessed with the beam walk and cylinder tests.ResultsTH and TH+PB induced neuroprotection, as measured by global brain damage score and improved motor function. Exploratory analyses suggest that TH+PB may confer enhanced protection, especially to the extent of damage.ConclusionProphylactic PB with TH is not deleterious and may provide additional long-term neuroprotection, including improvement of motor outcomes following HI in the term-equivalent, neonatal rat.
Glioblastoma multiforme (GBM) is the most common and aggressive primary intracranial brain tumor in adults with a mean survival of 14 to 15 months. Aberrant activation of the epidermal growth factor receptor (EGFR) plays a significant role in GBM progression, with amplification or overexpression of EGFR in 60% of GBM tumors. To target EGFR expressed by GBM, we have developed a strategy to deliver the coding sequence for cetuximab, an anti-EGFR antibody, directly to the CNS using an adeno-associated virus serotype rh.10 gene transfer vector. The data demonstrates that single, local delivery of an anti-EGFR antibody by an AAVrh.10 vector coding for cetuximab (AAVrh. 10Cetmab) reduces GBM tumor growth and increases survival in xenograft mouse models of a human GBM EGFR-expressing cell line and patient-derived GBM. AAVrh10.CetMab-treated mice displayed a reduction in cachexia, a significant decrease in tumor volume and a prolonged survival following therapy. Adeno-associated-directed delivery of a gene encoding a therapeutic anti-EGFR monoclonal antibody may be an effective strategy to treat GBM.
You have accessJournal of UrologyProstate Cancer: Detection & Screening I1 Apr 2016MP16-01 HIGH-RESOLUTION MAGNETIC RESONANCE IMAGING DIFFERENTIATES BETWEEN NORMAL HISTOMORPHOLOGICAL SIGNATURES AND PROSTATE CANCER IN THE RESECTED PROSTATE GLAND Matthieu Durand, Manu Jain, Brian Robinson, Eric Aronowitz, Youssef El Douahy, Robert Leung, Douglas S Scherr, Amelia Ng, Dominique Donzeau, Jean Amiel, Pascal Spincemaille, Arnauld Villers, and Douglas Ballon Matthieu DurandMatthieu Durand More articles by this author , Manu JainManu Jain More articles by this author , Brian RobinsonBrian Robinson More articles by this author , Eric AronowitzEric Aronowitz More articles by this author , Youssef El DouahyYoussef El Douahy More articles by this author , Robert LeungRobert Leung More articles by this author , Douglas S ScherrDouglas S Scherr More articles by this author , Amelia NgAmelia Ng More articles by this author , Dominique DonzeauDominique Donzeau More articles by this author , Jean AmielJean Amiel More articles by this author , Pascal SpincemaillePascal Spincemaille More articles by this author , Arnauld VillersArnauld Villers More articles by this author , and Douglas BallonDouglas Ballon More articles by this author View All Author Informationhttps://doi.org/10.1016/j.juro.2016.02.2566AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookTwitterLinked InEmail INTRODUCTION AND OBJECTIVES In vivo high-resolution magnetic resonance imaging (MRI) at a microscopic level for the identification of prostate cancer (PCa) has not yet been achieved. This may be accomplished using MRI with high spatial resolution for ex vivo examination of prostate specimens. The objective was to determine imaging protocol parameters for characterization of prostate tissue at histologic length scales. METHODS Rapid acquisition with relaxation enhancement, spin echo and gradient echo fast low angle shot data were acquired using ex vivo 3 Tesla or 7 Tesla magnetic field strengths from fresh prostatectomy specimens (n=15) obtained from either organ donor or PCa patients under Institutional Review Board approval. To achieve the closest correspondence between histopathological components and MRI images in terms of resolution and sectioning planes, multiple high resolution imaging protocols (ranging from few minutes to overnight) were tested. Ductograms were generated as part of image post-processing. Specimens were subsequently submitted for histopathological evaluation. RESULTS A total of 7 imaging protocols were tested (Table 1). Ex vivo 7 Tesla MRI identified normal components of prostate glands including ducts, blood vessels, concretions, and stroma at a spatial resolution of 60 X 60 X 60 µm3 to 107 X 107 X 500 µm3. A 7 Tesla spin echo image from a whole gland at a spatial resolution of 100 X 107 X 750 µm3 shown that the visible structures clearly approached the microscopic scale highlighting the microanatomy of intraprostatic tissue (Figure 1). Malignant glands and nests of tumor cells identified at 60 X 60 X 90 µm3 were highly comparable to low magnification (x2) histopathology. Ductograms enhanced the differentiation between benign and malignant glands. CONCLUSIONS We demonstrated that critical histopathological features of the prostate gland can be identified with high resolution ex vivo MRI examination and offer promise that MR microscopy of PCa will ultimately be possible in vivo. © 2016FiguresReferencesRelatedDetails Volume 195Issue 4SApril 2016Page: e159-e160 Advertisement Copyright & Permissions© 2016MetricsAuthor Information Matthieu Durand More articles by this author Manu Jain More articles by this author Brian Robinson More articles by this author Eric Aronowitz More articles by this author Youssef El Douahy More articles by this author Robert Leung More articles by this author Douglas S Scherr More articles by this author Amelia Ng More articles by this author Dominique Donzeau More articles by this author Jean Amiel More articles by this author Pascal Spincemaille More articles by this author Arnauld Villers More articles by this author Douglas Ballon More articles by this author Expand All Advertisement Advertisement PDF downloadLoading ...
To determine imaging protocol parameters for characterization of prostate tissue at histological length scales.Rapid acquisition with relaxation enhancement, spin echo and gradient echo fast low angle shot data were acquired using ex vivo 3-Tesla or 7-Tesla magnetic field strengths from fresh prostatectomy specimens (n = 15) obtained from either organ donor or patients with prostate cancer (PCa). To achieve the closest correspondence between histopathological components and magnetic resonance imaging (MRI) results, in terms of resolution and sectioning planes, multiple high-resolution imaging protocols (ranging from a few minutes to overnight) were tested. Ductograms were generated as part of image post-processing. Specimens were subsequently submitted for histopathological evaluation.A total of seven imaging protocols were tested. Ex vivo 7-Tesla MRI identified normal components of prostate glands, including ducts, blood vessels, concretions and stroma at a spatial resolution of 60 × 60 × 60 μm3 to 107 × 107 × 500 μm3 . Malignant glands and nests of tumour cells identified at 60 × 60 × 90 μm3 were highly similar to low-magnification (×2) histopathology. Ductograms enhanced the differentiation between benign and malignant glands. The results of the present study were encouraging, and further work is warranted with a larger sample size.We showed that critical histopathological features of the prostate gland can be identified with high-resolution ex vivo MRI examination and this offers promise that MRI microscopy of PCa will ultimately be possible in vivo.
Pathologic evaluation of breast specimens requires a fixation and staining procedure of at least 12 hours duration, delaying diagnosis and post-operative planning. Here we introduce an MRI technique with a custom-designed radiofrequency resonator for imaging breast and lymph tissue with sufficient spatial resolution and speed to guide pathologic interpretation and offer value in clinical decision making. In this study, we demonstrate the ability to image breast and lymphatic tissue using 7.0 Tesla MRI, achieving a spatial resolution of 59 × 59 × 94 μm3 with a signal-to-noise ratio of 15–20, in an imaging time of 56 to 70 minutes. These are the first MR images to reveal characteristic pathologic features of both benign and malignant breast and lymph tissue, some of which were discernible by blinded pathologists who had no prior training in high resolution MRI interpretation.
Hypoxic–ischemic encephalopathy (HIE) is a major cause of morbidity in survivors. Therapeutic hypothermia (TH) is the only available intervention, but the protection is incomplete. Preclinical studies of HIE/TH in the rodent have relied on the postnatal day (P) 7 rat whose brain approximates a 32–36 wk gestation infant, less relevant for these studies. We propose that HIE and TH in the term-equivalent P10 rat will be more translational. P10-11 rat pups were subjected to unilateral hypoxia–ischemia (HI) and 4 h recovery in normothermic (N) or hypothermic (TH) conditions. Brain damage was assessed longitudinally at 24 h, 2 wk, and 12 wk. Motor function was assessed with the beam walk; recognition memory was measured by novel object recognition. Neuroprotection with TH was apparent at 2 and 12 wk in both moderately and severely damaged animals. TH improved motor function in moderate, but not severe, damage. Impaired object recognition occurred with severe damage with no evidence of protection of TH. This adaptation of the immature rat model of HI provides a reproducible platform to further study HIE/TH in which individual animals are followed up longitudinally to provide a useful translational preclinical model.
The median survival of glioblastoma multiforme (GBM) is approximately 1 year. Following surgical removal, systemic therapies are limited by the blood-brain barrier. To circumvent this, we developed a method to modify neurons with the genetic sequence for therapeutic monoclonal antibodies using adeno-associated virus (AAV) gene transfer vectors, directing persistent, local expression in the tumor milieu. The human U87MG GBM cell line or patient-derived early passage GBM cells were administered to the striatum of NOD/SCID immunodeficient mice. AAVrh.10BevMab, an AAVrh.10-based vector coding for bevacizumab (Avastin), an anti-human vascular endothelial growth factor (VEGF) monoclonal antibody, was delivered to the area of the GBM xenograft. Localized expression of bevacizumab was demonstrated by quantitative PCR, ELISA and western blotting. Immunohistochemistry showed that bevacizumab was expressed in neurons. Concurrent administration of AAVrh. 10BevMab with the U87MG tumor reduced tumor blood vessel density and tumor volume, and increased survival. Administration of AAVrh.10BevMab 1 week after U87MG xenograft reduced growth and increased survival. Studies with patient-derived early passage GBM primary cells showed a reduction in primary tumor burden with an increased survival. These data support the strategy of AAV-mediated central nervous system gene therapy to treat GBM, overcoming the blood-brain barrier through local, persistent delivery of an anti-angiogenesis monoclonal antibody.
Object. Tissue-engineered intervertebral discs (TE-IVDs) represent a new experimental approach for the treatment of degenerative disc disease. Compared with mechanical implants, TE-IVDs may better mimic the properties of native discs. The authors conducted a study to evaluate the outcome of TE-IVDs implanted into the rat-tail spine using radiological parameters and histology.Methods. Tissue-engineered intervertebral discs consist of a distinct nucleus pulposus (NP) and anulus fibrosus (AF) that are engineered in vitro from sheep IVD chondrocytes. In 10 athymic rats a discectomy in the caudal spine was performed. The discs were replaced with TE-IVDs. Animals were kept alive for 8 months and were killed for histological evaluation. At 1,5, and 8 months, MR images were obtained; T1-weighted sequences were used for disc height measurements, and T2-weighted sequences were used for morphological analysis. Quantitative T2 relaxation time analysis was used to assess the water content and Tip-relaxation time to assess the proteoglycan content of TE-IVDs.Results. Disc height of the transplanted segments remained constant between 68% and 74% of healthy discs. Examination of TE-IVDs on MR images revealed morphology similar to that of native discs. T2-relaxation time did not differ between implanted and healthy discs, indicating similar water content of the NP tissue. The size of the NP decreased in TE-IVDs. Proteoglycan content in the NP was lower than it was in control discs. Ossification of the implanted segment was not observed. Histological examination revealed an AF consisting of an organized parallel-aligned fiber structure. The NP matrix appeared amorphous and contained cells that resembled chondrocytes.Conclusions. The TB-IVDs remained viable over 8 months in vivo and maintained a structure similar to that of native discs. Tissue-engineered intervertebral discs should be explored further as an option for the potential treatment of degenerative disc disease.
Object Tissue-engineered intervertebral discs (TE-IVDs) represent a new experimental approach for the treatment of degenerative disc disease. Compared with mechanical implants, TE-IVDs may better mimic the properties of native discs. The authors conducted a study to evaluate the outcome of TE-IVDs implanted into the rat-tail spine using radiological parameters and histology. Methods Tissue-engineered intervertebral discs consist of a distinct nucleus pulposus (NP) and anulus fibrosus (AF) that are engineered in vitro from sheep IVD chondrocytes. In 10 athymic rats a discectomy in the caudal spine was performed. The discs were replaced with TE-IVDs. Animals were kept alive for 8 months and were killed for histological evaluation. At 1, 5, and 8 months, MR images were obtained; T1-weighted sequences were used for disc height measurements, and T2-weighted sequences were used for morphological analysis. Quantitative T2 relaxation time analysis was used to assess the water content and T1ρ-relaxation time to assess the proteoglycan content of TE-IVDs. Results Disc height of the transplanted segments remained constant between 68% and 74% of healthy discs. Examination of TE-IVDs on MR images revealed morphology similar to that of native discs. T2-relaxation time did not differ between implanted and healthy discs, indicating similar water content of the NP tissue. The size of the NP decreased in TE-IVDs. Proteoglycan content in the NP was lower than it was in control discs. Ossification of the implanted segment was not observed. Histological examination revealed an AF consisting of an organized parallel-aligned fiber structure. The NP matrix appeared amorphous and contained cells that resembled chondrocytes. Conclusions The TE-IVDs remained viable over 8 months in vivo and maintained a structure similar to that of native discs. Tissue-engineered intervertebral discs should be explored further as an option for the potential treatment of degenerative disc disease.
Study Design. Animal experimental study.Objective. To evaluate a novel quantitative imaging technique for assessing disc degeneration.Summary of Background Data. T2-relaxation time (T2-RT) measurements have been used to assess disc degeneration quantitatively. T2 values correlate with the water content of intervertebral disc tissue and thereby allow for the indirect measurement of nucleus pulposus (NP) hydration.Methods. We developed an algorithm to subtract out magnetic resonance imaging (MRI) voxels not representing NP tissue on the basis of T2-RT values. Filtered NP voxels were used to measure nuclear size by their amount and nuclear hydration by their mean T2-RT. This technique was applied to 24 rat-tail intervertebral discs (IVDs), which had been punctured with an 18-gauge needle according to different techniques to induce varying degrees of degeneration. NP voxel count and average T2-RT were used as parameters to assess the degeneration process at 1 and 3 months postpuncture. NP voxel counts were evaluated against radiograph disc height measurements and qualitative MRI studies on the basis of the Pfirrmann grading system. Tails were collected for histology to correlate NP voxel counts to histological disc degeneration grades and to NP cross-sectional area measurements.Results. NP voxel count measurements showed strong correlations to qualitative MRI analyses (R-2=0.79, P < 0.0001), histological degeneration grades (R-2=0.902, P < 0.0001), and histological NP cross-sectional area measurements (R-2=0.887, P < 0.0001). In contrast to NP voxel counts, the mean T2-RT for each punctured group remained constant between months 1 and 3. The mean T2RTs for the punctured groups did not show a statistically significant difference from those of healthy IVDs (63.55 ms +/- 5.88 ms mo 1 and 62.61 ms +/- 5.02 ms) at either time point.Conclusion. The NP voxel count proved to be a valid parameter to assess disc degeneration quantitatively in a needle puncture model. The mean NP T2-RT does not change significantly in needlepuncture-induced degenerated IVDs. IVDs can be segmented into different tissue components according to their innate T2-RT.