Probe-based capture represents a highly sensitive and cost-effective approach for overcoming host background and enriching viruses in metagenomic NGS (mNGS) libraries. Using clinical specimens collected globally from patients with fever or respiratory illness, we generated mNGS libraries by random priming and Nextera XT tagmentation, followed by target enrichment (teNGS) with Comprehensive Viral Research Panel (CVRP) probes. Capture pool sizes and total reads were optimized, and libraries were initially sequenced separately. Using only 3–4% of reads required for standard mNGS, teNGS achieved increased sensitivity, 100–10,000× increases in depth, and >50% genome coverage for pathogens with titers ≥ 1000 cp/mL. Application to >2000 clinical specimens from various matrices and to contrived samples containing viruses absent from the CVRP probe set enabled detection of diverse viral families and established a minimum 65% nucleotide identity for hybridization, respectively. To save time and resources, teNGS and mNGS libraries were then combined into one sequencing run: teamNGS. In addition to streamlining the workflow, teamNGS also improved genome recovery. Coupling methods maintain the sensitivity and coverage for viruses achieved by enrichment alone while also ensuring comprehensive recovery of non-viral microbes. teamNGS has the potential to improve patient management and lower the rates of unnecessary testing and antibiotic use.
Abstract Objectives To evaluate pre-analytical challenges related to high-volume central laboratory SARS-CoV-2 antigen testing with a prototype qualitative SARS-CoV-2 antigen immunoassay run on the automated Abbott ARCHITECT instrument. Methods Contrived positive and negative specimens and de-identified nasal and nasopharyngeal specimens in transport media were used to evaluate specimen and reagent on-board stability, assay analytical performance and interference, and clinical performance. Results TCID50/mL values were similar for specimens in various transport media. Inactivated positive clinical specimens and viral lysate (USA-WA1/2020) were positive on the prototype immunoassay. Within-laboratory imprecision was ≤0.10 SD (<1.00 S/C) with a ≤10% CV (≥1.00 S/C). Assay reagents were stable on board the instrument for 14 days. No high-dose hook effect was observed with a SARS-CoV-2 stock of Ct 13.0 (RLU>1.0 × 106). No interference was observed from mucin, whole blood, 12 drugs, and more than 20 cross-reactants. While specimen stability was limited at room temperature for specimens with or without viral inactivation, a single freeze/thaw cycle or long-term storage (>30 days) at −20 °C did not adversely impact specimen stability or assay performance. Specificity of the prototype SARS-CoV-2 antigen immunoassay was ≥98.5% and sensitivity was ≥89.5% across two ARCHITECT instruments. Assay sensitivity was inversely correlated with Ct and was similar to that reported for the Roche Elecsys® SARS-CoV-2 Ag immunoassay. Conclusions The prototype SARS-CoV-2 antigen ARCHITECT immunoassay is sensitive and specific for detection of SARS-CoV-2 in nasal and nasopharyngeal specimens. Endogenous proteases in mucus may degrade the target antigen, which limits specimen storage and transport times and complicates assay workflow.
Virus-like particle (VLP) and live virus assays were used to investigate neutralizing immunity against Delta and Omicron SARS-CoV-2 variants in 259 samples from 128 vaccinated individuals. Following Delta breakthrough infection, titers against WT rose 57-fold and 3.1-fold compared with uninfected boosted and unboosted individuals, respectively, versus only a 5.8-fold increase and 3.1-fold decrease for Omicron breakthrough infection. Among immunocompetent, unboosted patients, Delta breakthrough infections induced 10.8-fold higher titers against WT compared with Omicron (p = 0.037). Decreased antibody responses in Omicron breakthrough infections relative to Delta were potentially related to a higher proportion of asymptomatic or mild breakthrough infections (55.0% versus 28.6%, respectively), which exhibited 12.3-fold lower titers against WT compared with moderate to severe infections (p = 0.020). Following either Delta or Omicron breakthrough infection, limited variant-specific cross-neutralizing immunity was observed. These results suggest that Omicron breakthrough infections are less immunogenic than Delta, thus providing reduced protection against reinfection or infection from future variants.
Severe acute respiratory syndrome-related coronavirus (SARS-CoV-2) transmission occurs even among fully vaccinated individuals; thus, prompt identification of infected patients is central to control viral circulation. Antigen rapid diagnostic tests (Ag-RDTs) are highly specific, but sensitivity is variable. Discordant RT-qPCR vs. Ag-RDT results are reported, raising the question of whether negative Ag-RDT in positive RT-qPCR samples could imply the absence of infectious viruses. To study the relationship between negative Ag-RDT results with virological, molecular, and serological parameters, we selected a cross-sectional and a follow-up dataset and analyzed virus culture, subgenomic RNA quantification, and sequencing to determine infectious viruses and mutations. We demonstrated that RT-qPCR positive while SARS-CoV-2 Ag-RDT negative discordant results correlate with the absence of infectious virus in nasopharyngeal samples. A decrease in sgRNA detection together with an expected increase in detectable anti-S and anti-N IgGs was also verified in these samples. The data clearly demonstrate that a negative Ag-RDT sample is less likely to harbor infectious SARS-CoV-2 and, consequently, has a lower transmissible potential.
This repository contains the pertinent datasets used in the manuscript, Predominance of antibody-resistant SARS-CoV-2 variants in vaccine breakthrough cases from the San Francisco Bay Area, California.
There is an urgent need to understand the dynamics and risk factors driving ongoing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) transmission during shelter-in-place mandates. We offered SARS-CoV-2 reverse-transcription polymerase chain reaction (PCR) and antibody (Abbott ARCHITECT IgG) testing, regardless of symptoms, to all residents (aged ≥4 years) and workers in a San Francisco census tract (population: 5174) at outdoor, community-mobilized events over 4 days. We estimated SARS-CoV-2 point prevalence (PCR positive) and cumulative incidence (antibody or PCR positive) in the census tract and evaluated risk factors for recent (PCR positive/antibody negative) vs prior infection (antibody positive/PCR negative). SARS-CoV-2 genome recovery and phylogenetics were used to measure viral strain diversity, establish viral lineages present, and estimate number of introductions. We tested 3953 persons (40% Latinx; 41% White; 9% Asian/Pacific Islander; and 2% Black). Overall, 2.1% (83/3871) tested PCR positive: 95% were Latinx and 52% were asymptomatic when tested; 1.7% of census tract residents and 6.0% of workers (non–census tract residents) were PCR positive. Among 2598 tract residents, estimated point prevalence of PCR positives was 2.3% (95% confidence interval [CI], 1.2%–3.8%): 3.9% (95% CI, 2.0%–6.4%) among Latinx persons vs 0.2% (95% CI, .0–.4%) among non-Latinx persons. Estimated cumulative incidence among residents was 6.1% (95% CI, 4.0%–8.6%). Prior infections were 67% Latinx, 16% White, and 17% other ethnicities. Among recent infections, 96% were Latinx. Risk factors for recent infection were Latinx ethnicity, inability to shelter in place and maintain income, frontline service work, unemployment, and household income <$50 000/year. Five SARS-CoV-2 phylogenetic lineages were detected. SARS-CoV-2 infections from diverse lineages continued circulating among low-income, Latinx persons unable to work from home and maintain income during San Francisco’s shelter-in-place ordinance.
Interpretation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serosurveillance studies is limited by poorly defined performance of antibody assays over time in individuals with different clinical presentations. We measured antibody responses in plasma samples from 128 individuals over 160 days using 14 assays. We found a consistent and strong effect of disease severity on antibody magnitude, driven by fever, cough, hospitalization, and oxygen requirement. Responses to spike protein versus nucleocapsid had consistently higher correlation with neutralization. Assays varied substantially in sensitivity during early convalescence and time to seroreversion. Variability was dramatic for individuals with mild infection, who had consistently lower antibody titers, with sensitivities at 6 months ranging from 33 to 98% for commercial assays. Thus, the ability to detect previous infection by SARS-CoV-2 is highly dependent on infection severity, timing, and the assay used. These findings have important implications for the design and interpretation of SARS-CoV-2 serosurveillance studies.
BACKGROUND:Early detection of acute HIV infection by HIV antigen/antibody assays depends on antigen sensitivity. Maintaining consistently high sensitivity across diverse HIV strains is critical to ensure equal detection.OBJECTIVES:The performance of an improved HIV antigen/antibody prototype, HIV Combo Next, was evaluated for detection of genetically-diverse HIV strains and seroconversion samples.STUDY DESIGN:Antigen sensitivity of the prototype was evaluated and compared to five FDA-approved HIV antigen/antibody assays using World Health Organization (WHO) HIV p24 antigen standard and reference panels, 17 virus isolates and 9 seroconversion panels. Antibody sensitivity and assay specificity of the prototype were also assessed with 1062 disease-staged and genotyped samples, and samples from 3000 blood donors and 955 individuals with low-risk for HIV infection.RESULTS:Compared with other assays evaluated, the prototype demonstrated the best analytical sensitivity for WHO antigen standard, reference panels including 12 HIV-1 variants (0.04 - 0.25 IU/ml) and one HIV-2 variant, and 17 HIV virus isolates including HIV-1 group M, N, P and O and HIV-2 (0.3 -16 pg/ml). The enhanced sensitivity was also observed for seroconversion samples, detecting more PCR-positive samples with detection up to 7 days earlier than the other assays. Improvement in antigen sensitivity did not compromise antibody sensitivity or assay specificity, detecting all HIV disease-staged and genotyped samples, with assay specificity of 99.97% for blood donors and 99.68% for the low-risk population.CONCLUSIONS:These data indicate that the new prototype HIV Combo Next assay will be of diagnostic value, providing improved early detection for acute HIV infection from divergent HIV strains.
Background. Limited systematic surveillance for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the early months of the US epidemic curtailed accurate appraisal of transmission intensity. Our objective was to perform case detection of an entire rural community to quantify SARS-CoV-2 transmission using polymerase chain reaction (PCR) and antibody testing. Methods. We conducted a cross-sectional survey of SARS-CoV-2 infection in the rural town of Bolinas, California (population 1620), 4 weeks after shelter-in-place orders. Participants were tested between April 20 and 24, 2020. Prevalence by PCR and seroprevalence from 2 forms of antibody testing were performed in parallel (Abbott ARCHITECT immunoglobulin [Ig]G and in-house IgG enzyme-linked immunosorbent assay). Results. Of 1891 participants, 1312 were confirmed Bolinas residents (>80% community ascertainment). Zero participants were PCR positive. Assuming 80% sensitivity, it would have been unlikely to observe these results (P < .05) if there were >3 active infections in the community. Based on antibody results, estimated prevalence of prior infection was 0.16% (95% credible interval [CrI], 0.02%-0.46%). The positive predictive value (PPV) of a positive result on both tests was 99.11% (95% CrI, 95.75%-99.94%), compared with PPV 44.19%-63.32% (95% CrI, 3.25%-98.64%) if 1 test was utilized. Conclusions. Four weeks after shelter-in-place, SARS-CoV-2 infection in a rural Northern California community was extremely rare. In this low-prevalence setting, use of 2 antibody tests increased seroprevalence estimate precision. This was one of the first communitywide studies to successfully implement synchronous PCR and antibody testing, particularly in a rural setting. Widespread testing remains an underpinning of effective disease control in conjunction with consistent uptake of public health measures.
BACKGROUND:The absence of systematic surveillance for SARS-CoV-2 has curtailed accurate appraisal of transmission intensity. Our objective was to perform case detection of an entire rural community to quantify SARS-CoV-2 transmission using PCR and antibody testing. METHODS:We conducted a cross-sectional survey of the prevalence and cumulative incidence of SARS-CoV-2 infection in the rural town of Bolinas, California (population 1,620), four weeks following shelter-in-place orders. Residents and county essential workers were tested between April 20th-24th, 2020. Prevalence by PCR and seroprevalence combining data from two forms of antibody testing were performed in parallel (Abbott ARCHITECT IgG to nucleocapsid protein and in-house IgG ELISA to the receptor binding domain). RESULTS:Of 1,891 participants, 1,312 were confirmed Bolinas residents (>80% community ascertainment). Zero participants were PCR positive. Assuming 80% sensitivity, it would have been unlikely to observe these results (p<0.05) if there were >3 active infections in the community. Based on antibody results, estimated prevalence of prior infection was 0.16% (95% CrI: 0.02%, 0.46%). Seroprevalence estimates using only one of the two tests would have been higher, with greater uncertainty. The positive predictive value (PPV) of a positive result on both tests was 99.11% (95% CrI: 95.75%, 99.94%), compared to PPV 44.19%-63.32% (95% CrI range 3.25%-98.64%) if only one test was utilized. CONCLUSIONS:Four weeks following shelter-in-place, active and prior SARS-CoV-2 infection in a rural Northern California community was extremely rare. In this low prevalence setting, use of two antibody tests increased the PPV and precision of seroprevalence estimates.
ABSTRACT Background We characterized SARS-CoV-2 infections in a densely-populated, majority Latinx San Francisco community six-weeks into the city’s shelter-in-place order. Methods We offered SARS-CoV-2 reverse transcription-PCR and antibody (Abbott ARCHITECT IgG) testing, regardless of symptoms, to all residents (>4 years) and workers in a San Francisco census tract (population: 5,174) at outdoor, community-mobilized events over four days. We estimated SARS-CoV-2 point prevalence (PCR-positive) and cumulative incidence (antibody or PCR-positive) in the census tract and evaluated risk factors for recent (PCR-positive/antibody-negative) versus prior infection (antibody-positive/PCR-negative). SARS-CoV-2 genome recovery and phylogenetics were used to measure viral strain diversity, establish viral lineages present, and estimate number of introductions. Results We tested 3,953 persons: 40% Latinx; 41% White; 9% Asian/Pacific Islander; and 2% Black. Overall, 2.1% (83/3,871) tested PCR-positive: 95% were Latinx and 52% asymptomatic when tested. 1.7% of residents and 6.0% of workers (non-census tract residents) were PCR-positive. Among 2,598 census tract residents, estimated point prevalence of PCR-positives was 2.3% (95%CI: 1.2-3.8%): 3.9% (95%CI: 2.0-6.4%) among Latinx vs. 0.2% (95%CI: 0.0-0.4%) among non-Latinx persons. Estimated cumulative incidence among residents was 6.1% (95%CI: 4.0-8.6%). Prior infections were 67% Latinx, 16% White, and 17% other ethnicities. Among recent infections, 96% were Latinx. Risk factors for recent infection were Latinx ethnicity, inability to shelter-in-place and maintain income, frontline service work, unemployment, and household income <$50,000/year. Five SARS-CoV-2 phylogenetic lineages were detected. Conclusion SARS-CoV-2 infections from diverse lineages continued circulating among low-income, Latinx persons unable to work from home and maintain income during San Francisco’s shelter-in-place ordinance.
Background Diagnosis of people living with HIV (PLHIV) is the first step toward achieving the new Fast Track Strategy to end AIDS by 2030: 95-95-95. However, reaching PLHIV is especially difficult in resource-limited settings such as the Democratic Republic of Congo (DRC), where reliable prevalence data is lacking. This study evaluated the prevalence of HIV in patients in the urban Kinshasa area. Methods Individuals seeking healthcare were tested for HIV between February 2017 and July 2018 at existing Kinshasa urban clinics. The study was conducted in two phases. Case finding was optimized in a pilot study phase using a modified cell phone-based Open\Data Kit (ODK) collection system. HIV prevalence was then determined from data obtained between March–July of 2018 from 8320 individuals over the age of 18 years receiving care at one of 47 clinics in Kinshasa. Results The prevalence of HIV in our study was 11.0% (95% CI 10.3–11.6%) overall and 8.14% in the subset of N = 1240 participants who were healthy mothers seeking prenatal care. These results are in sharp contrast to President's Emergency Plan for AIDS Relief (PEPFAR) estimates of 2.86%, but are consistent with data from surrounding countries. Conclusion While this data is sub-national and reflects an urban healthcare setting, given the large population of Kinshasa and rapidly changing age demographics, the results suggest that HIV prevalence in the DRC is substantially higher than previously reported.
Given the limited availability of serological testing to date, the seroprevalence of SARS-CoV-2-specific antibodies in different populations has remained unclear. Here, we report very low SARS-CoV-2 seroprevalence in two San Francisco Bay Area populations. Seroreactivity was 0.26% in 387 hospitalized patients admitted for non-respiratory indications and 0.1% in 1,000 blood donors in early April 2020. We additionally describe the longitudinal dynamics of immunoglobulin-G (IgG), immunoglobulin-M (IgM), and in vitro neutralizing antibody titers in COVID-19 patients. The median time to seroconversion ranged from 10.3–11.0 days for these 3 assays. Neutralizing antibodies rose in tandem with immunoglobulin titers following symptom onset, and positive percent agreement between detection of IgG and neutralizing titers was >93%. These findings emphasize the importance of using highly accurate tests for surveillance studies in low-prevalence populations, and provide evidence that seroreactivity using SARS-CoV-2 anti-nucleocapsid protein IgG and anti-spike IgM assays are generally predictive of in vitro neutralizing capacity.
Surveillance of human immunodeficiency virus (HIV) molecular diversity and drug resistance-associated mutations (DRMs) among treatment-naïve blood donors is critical for monitoring viral evolution and blood safety. From 2016-2017, 199 plasma samples were collected from 24 blood centers and confirmed as HIV viral load positive or serologically reactive in National Centers for Clinical Laboratories (NCCL), of which 179 were sequenced and subtyped in the gag , protease (PR)- reverse transcriptase (RT), integrase (IN) and/or envelope ( env ) regions. DRMs in PR-RT and IN regions were analyzed in Stanford HIVdb Program. The majority of subtypes were circulating recombinant form (CRF) 07_BC (34.6%) and CRF01_AE (32.4%); many unique recombinant forms (URFs) (39, 21.8%) and other rare CRFs were observed in the study. Notably, CRF02_AG and CRF06_cpx strains typically found in Africa were firstly identified amongst Chinese blood donors. DRMs were common, with 28 of 179 (15.6%) specimens carrying DRMs, including the PR N88S and RT K103N mutations, which have been implicated in elevated resistance to antiretroviral drugs. Furthermore, 4 HIV-1 isolates (2.4%, 4/168) had surveillance drug-resistance mutation (SDRM), including 3 nonnucleoside reverse transcriptase inhibitors (NNRTI) SDRMs (1 K101E, 2 K103N) and 1 protease inhibitor (PI) SDRM (M46I). The HIV viral diversity among blood donors observed in this study suggest that ongoing HIV-1 recombination is becoming progressively complex in China, and lots of DRMs found in the study exacerbate the primary drug resistance landscape, which highlight the necessity of timely genotypic drug resistance monitoring and molecular surveillance of HIV-1 among blood donors.
Most human pegivirus 2 (HPgV-2) infections are associated with past or current hepatitis C virus (HCV) infection. HPgV-2 is thought to be a bloodborne virus: higher prevalence of active infection has been found in populations with a history of parenteral exposure to viruses. We evaluated longitudinally collected blood samples obtained from injection drug users (IDUs) for active and resolved HPgV-2 infections using a combination of HPgV-2–specific molecular and serologic tests. We found evidence of HPgV-2 infection in 11.2% (22/197) of past or current HCV-infected IDUs, compared with 1.9% (4/205) of an HCV-negative IDU population. Testing of available longitudinal blood samples from HPgV-2–positive participants identified 5 with chronic infection (>6 months viremia in >3 timepoints); 2 were identified among the HCV-positive IDUs and 3 among the HCV-negative IDUs. Our findings indicate that HPgV-2 can establish chronic infection and replicate in the absence of HCV.
ABSTRACT We report very low SARS-CoV-2 seroprevalence in two San Francisco Bay Area populations. Seropositivity was 0.26% in 387 hospitalized patients admitted for non-respiratory indications and 0.1% in 1,000 blood donors. We additionally describe the longitudinal dynamics of immunoglobulin-G, immunoglobulin-M, and in vitro neutralizing antibody titers in COVID-19 patients. Neutralizing antibodies rise in tandem with immunoglobulin levels following symptom onset, exhibiting median time to seroconversion within one day of each other, and there is >93% positive percent agreement between detection of immunoglobulin-G and neutralizing titers.
Metagenomic next-generation sequencing (mNGS), the shotgun sequencing of RNA and DNA from clinical samples, has proved useful for broad-spectrum pathogen detection and the genomic surveillance of viral outbreaks. An additional target enrichment step is generally needed for high-sensitivity pathogen identification in low-titre infections, yet available methods using PCR or capture probes can be limited by high cost, narrow scope of detection, lengthy protocols and/or cross-contamination. Here, we developed metagenomic sequencing with spiked primer enrichment (MSSPE), a method for enriching targeted RNA viral sequences while simultaneously retaining metagenomic sensitivity for other pathogens. We evaluated MSSPE for 14 different viruses, yielding a median tenfold enrichment and mean 47% (±16%) increase in the breadth of genome coverage over mNGS alone. Virus detection using MSSPE arboviral or haemorrhagic fever viral panels was comparable in sensitivity to specific PCR, demonstrating 95% accuracy for the detection of Zika, Ebola, dengue, chikungunya and yellow fever viruses in plasma samples from infected patients. Notably, sequences from re-emerging and/or co-infecting viruses that have not been specifically targeted a priori, including Powassan and Usutu, were successfully enriched using MSSPE. MSSPE is simple, low cost, fast and deployable on either benchtop or portable nanopore sequencers, making this method directly applicable for diagnostic laboratory and field use.
A serological survey of 2,430 archived serum samples collected between 1997 and 2012 was conducted to retrospectively determine the prevalence of Marburg virus in five African countries. Serum samples were screened for neutralizing antibodies in a pseudotype micro-neutralization assay and confirmed by enzyme-linked immunosorbent assay (ELISA). Surprisingly, a seroprevalence for Marburg virus of 7.5 and 6.3% was found in Cameroon and Ghana, respectively, suggesting the circulation of filoviruses or related viruses outside of known endemic areas that remain undetected by current surveillance efforts. However, due to the lack of validated assays and appropriate positive controls, these results must be considered preliminary.
We conducted a serologic survey of 2,430 serum samples collected during 1997–2012 for various studies to determine the prevalence of the hemorrhagic fever virus Ebola virus (EBOV) in equatorial Africa. We screened serum samples for neutralizing antibodies by using a pseudotype microneutralization assay and a newly developed luciferase immunoprecipitation system assay. Specimens seroreactive for EBOV were confirmed by using an ELISA. Our results suggest a serologic prevalence of 2%–3.5% in the Republic of the Congo and the Democratic Republic of the Congo, which have reported outbreaks of infection with EBOV. In addition we detected a seroprevalence of 1.3% in southern Cameroon, which indicated a low risk for exposure in this region.
In light of the advances in HCV therapy, simplification of diagnosis confirmation, pre- treatment diagnostic workup and treatment monitoring is required to ensure broad access to interferon-free therapies. HCV core antigen (HCV cAg) testing is rapid, giving results in approximately 60min, and less expensive than HCV RNA methods. While extensive data on the analytical performance of HCV cAg relative to RNA or comparisons in longitudinal studies of patients on interferon based (response guided) therapy there is very limited data on the relative performance of HCV cAg in diagnosis and monitoring patients receiving all-oral interferon free regimens. Furthermore, there is no data in the literature that describes the specificity of HCV cAg in patients with resolved HCV infection i.e. anti-HCV positive/HCV RNA negative. In this study a total of 1201 plasma samples from the 411 HCV genotype 1 subjects with a HCV RNA viral load >50,000IU/ml who enrolled in a clinical trial with ombitasvir, ritonavir-boosted paritaprevir and dasabuvir, with or without ribavirin were retrospectively tested in a blinded fashion with HCV cAg test and results were compared to HCV RNA levels. The specificity of the HCV cAg test was also evaluated in anti-HCV positive but HCV RNA negative samples. Overall concordance between HCV cAg and HCV RNA was 98.6% while concordance in pre-treatment samples was 99.5% (409/411; n=2 HCV RNA pos. with viral loads>3 Mill IU/ml but HCV cAg neg.) and 99.24% in post treatment week 12 samples (391/394; n=2 HCV RNA pos.<25IU/ml and n=1 HCV RNA pos. 2180IU/ml). Specificity in anti-HCV positive HCV RNA negative samples tested was 100%.