The NIFFTE fission Time Projection Chamber (fissionTPC) has been used to measure the ^239Pu(n,f)/^235U(n,f) cross-section ratio for neutron-induced fission in the range of 0.1 - 100 MeV, with high precision. A white neutron source was provided by the Los Alamos Neutron Science Center, where the experiment was conducted as a remeasurement to evaluate a roughly 2 discrepancy of the previous fissionTPC results with ENDF/B-VIII.0. A detailed accounting of measurement uncertainties was performed, based on the fissionTPC's novel ability to provide three-dimensional reconstruction of fission-fragment ionization profiles. Current results obtained using a vapor-deposited, highly uniform ^239Pu target, in comparison to the measurement published in 2021, where a ^239Pu electroplated target was used, are presented and discussed. The remeasurement presented here is in agreement with the previous fissionTPC result within measurement uncertainties.
The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of % = 40.8 degrees + 0.7 degrees and theta = 98.6 degrees + 0.4 degrees, the PROSPECT-I detector is able to reconstruct an average neutrino direction of % = 39.4 degrees + 2.9 degrees and theta = 97.6 degrees + 1.6 degrees. This measurement is made with approximately 48 000 inverse beta decay signal events and is the most precise directional reconstruction of reactor antineutrinos to date.
We present initial results on nuclear recoil detection based on the fluorescence of color centers created by nuclear recoils in lithium fluoride. We use gamma rays, fast and thermal neutrons, and study the difference in responses they induce, showing that this type of detector is rather insensitive to gamma rays. We use light-sheet fluorescence microscopy to image nuclear recoil tracks from fast and thermal neutron interactions deep inside a cubic-centimeter sized crystal and demonstrate automated feature extraction in three dimensions using machine learning tools. The number, size, and topology of the events agree with expectations based on simulations with TRIM. These results constitute the first step towards 10-1000g scale detectors with single-event sensitivity for applications such as the detection of dark matter particles, reactor neutrinos, and neutrons.
Nuclear fission reactors are abundant sources of antineutrinos for neutrino physics experiments. The flux and spectrum of antineutrinos emitted by a reactor can indicate its activity and composition, suggesting potential applications of neutrino measurements beyond fundamental scientific studies that may be valuable to society. The utility of reactor antineutrinos for applications and fundamental science is dependent on the availability of precise predictions of these emissions. For example, in the last decade, disagreements between reactor antineutrino measurements and models have inspired revision of reactor antineutrino calculations and standard nuclear databases as well as searches for new fundamental particles not predicted by the Standard Model of particle physics. Past predictions and descriptions of the methods used to generate them are documented to varying degrees in the literature, with different modeling teams incorporating a range of methods, input data, and assumptions. The resulting difficulty in accessing or reproducing past models and reconciling results from differing approaches complicates the future study and application of reactor antineutrinos. The CONFLUX (Calculation Of Neutrino FLUX) software framework is a neutrino prediction tool built with the goal of simplifying, standardizing, and democratizing the process of reactor antineutrino flux calculations. CONFLUX includes three primary methods for calculating the antineutrino emissions of nuclear reactors or individual beta decays that incorporate common nuclear data and beta decay theory. The software is prepackaged with the current nuclear databases, including ENDF.B/VIII, JEFF-3.3, and ENSDF, and it includes the capability to predict time-dependent reactor emissions, adjust nuclear database or beta decay inputs/assumptions, and propagate related sources of uncertainty. This paper describes the CONFLUX software structure, details the methods used for flux and spectrum calculations, and provides examples of potential use cases. Program summary Program Title: CONFLUX CPC Library link to program files: https://doi.org/10.17632/hvkr4bff8v.1 Developer's repository link: https://github.com/CNFLUX/conflux Licensing provisions: MIT Programming language: Python, C++ Nature of problem: The reactor antineutrino flux were calculated with various nuclear theories of beta-decay and different nuclear databases. The prediction of neutrino produced from nuclear reactors was hard to repeat, or used for in reactor-specific models. Calculations of the covariance among fission products and beta decay branches need more standard approaches. Solution method: We implement the CONFLUX software framework to standardize and simplify the calculation of reactor neutrino flux by modularize the nuclear databases, neutrino modeling methods, and the nuclear theories of beta-decay. So that the modeling of neutrinos from nuclear reactors can be done with minimum requirement of nuclear database, or the programming knowledge. The modules in the CONFLUX calculation are designed as customizeable and replaceable for updated and more accurate databases or beta-decay models.
The third “Mineral Detection of Neutrinos and Dark Matter” (MDνDM'25) meeting was held May 20-23, 2025 in Yokohama, Japan, hosted by the Yokohama Institute for Earth Sciences, Japan Agency for Marine-Earth Science and Technology (JAMSTEC). These proceedings compile contributions from the workshop and update the progress of mineral detector research. MDνDM'25 was the third such meeting, following the first in October of 2022 held at the IFPU in Trieste, Italy and the second in January of 2024 hosted by the Center for Neutrino Physics at Virginia Tech in Arlington, USA. Mineral detectors record and retain damage induced by nuclear recoils in synthetic or natural mineral samples. The damage features can then be read out by a variety of nano- and micro-scale imaging techniques. Applications of mineral detectors on timescales relevant for laboratory experiments include reactor neutrino monitoring and dark matter detection, with the potential to measure the directions as well as the energies of the induced nuclear recoils. For natural mineral detectors which record nuclear recoils over geological timescales, reading out even small mineral samples could be sensitive to rare interactions induced by astrophysical neutrinos, cosmic rays, dark matter and heavy exotic particles. A series of mineral detectors of different ages could measure the time evolution of these fluxes, offering a unique window into the history of our solar system and the Milky Way. Mineral detector research is highly multidisciplinary, incorporating aspects of high energy physics, condensed matter physics, materials science, geoscience, and AI/ML for data analysis. Although realizing the scientific potential of mineral detectors poses many challenges, the MDνDM community looks forward to the continued development of mineral detector experiments and the possible discoveries that mineral detectors could reveal.
The PROSPECT experiment is designed to perform precise searches for antineutrino disappearance at short distances (7-9 m) from compact nuclear reactor cores. This Letter reports results from a new neutrino oscillation analysis performed using the complete data sample from the PROSPECT-I detector operated at the High Flux Isotope Reactor in 2018. The analysis uses a multiperiod selection of inverse beta decay neutrino interactions with reduced backgrounds and enhanced statistical power to set limits on electron neutrino disappearance caused by mixing with sterile neutrinos with 0.2-20 eV^{2} mass splittings. Inverse beta decay positron energy spectra from six different reactor-detector distance ranges are found to be statistically consistent with one another, as would be expected in the absence of sterile neutrino oscillations. The data excludes at 95% confidence level the existence of sterile neutrinos in regions above 3 eV^{2} previously unexplored by terrestrial experiments, including all space below 10 eV^{2} suggested by the recently strengthened Gallium Anomaly. The best-fit point of the Neutrino-4 reactor experiment's claimed observation of short-baseline oscillation is ruled out at more than 5 standard deviations.
Nuclear reactors are uniquely powerful, abundant, and flavor-pure sources of antineutrinos that have played a central role in the discovery of the neutrinos and in elucidation of their properties. This continues through a broad range of experiments investigating topics including Standard Model and short-baseline oscillations, beyond-the-Standard-Model physics searches, and reactor flux and spectrum modelling. This Report will survey the state of the reactor antineutrino physics field and summarize the ways in which current and future reactor antineutrino experiments can play a critical role in advancing the field of particle physics in the next decade.
A 6 Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299- 50, has been developed and produced at the kilogram-scale. A total of 44 bars of dimensions 5.5 cm x 5.5 cm x 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to 6 Li-doped liquid scintillators. The scintillator EJ-299-50 shows good neutron detection capabilities with an effective efficiency for capture on 6 Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.
This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference, with emphasis on needs and options for future exploration that may lead to the ultimate resolution of the anomalies. We see the main experimental, analysis, and theory-driven thrusts that will be essential to achieving this goal being: 1) Cover all anomaly sectors -- given the unresolved nature of all four canonical anomalies, it is imperative to support all pillars of a diverse experimental portfolio, source, reactor, decay-at-rest, decay-in-flight, and other methods/sources, to provide complementary probes of and increased precision for new physics explanations; 2) Pursue diverse signatures -- it is imperative that experiments make design and analysis choices that maximize sensitivity to as broad an array of these potential new physics signatures as possible; 3) Deepen theoretical engagement -- priority in the theory community should be placed on development of standard and beyond standard models relevant to all four short-baseline anomalies and the development of tools for efficient tests of these models with existing and future experimental datasets; 4) Openly share data -- Fluid communication between the experimental and theory communities will be required, which implies that both experimental data releases and theoretical calculations should be publicly available; and 5) Apply robust analysis techniques -- Appropriate statistical treatment is crucial to assess the compatibility of data sets within the context of any given model.
One of the two detector material choices now being considered for the Mobile Antineutrino Demonstrator (MAD) project is 6 Li-doped pulse shape discriminating (PSD) plastic scintillator. This new material, manufactured by Eljen and designated EJ-299-50, continues the development of PSD plastic materials by the materials science group at LLNL, which invented PSD plastic in 2012. At present EJ-299-50 can be manufactured in multi-liter volumes with attenuation lengths approaching ~1 m. The MAD project is considering the use of this material in the form of 1 m long segments at 6 cm x 6 cm cross section. A 2D array of scintillator segments was shown to be an effective technique for above-ground reactor antineutrino detection by PROSPECT. For MAD, plastic material is considered a requirement for truly mobile above-ground detection systems suited to reactor monitoring for safeguards. In this presentation, we will summarize a set of key performance criteria, including attenuation length, stability, pulse shape sensitivity, and fast and slow neutron efficiency measurements and discuss how those performance criteria might translate to the overall performance of MAD.
Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the performance at the kilogram scale. The synthesis and processing of these plastic scintillators on the kilogram scale required examination of several factors. The examination of these factors was necessitated by the inclusion of 0.1 wt.% lithium-6 to enable detection of thermal neutrons. First, methacrylic acid was used as an additive to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that produces scintillation light following energy transfer. Second, a trade-off between scintillation performance and processability was considered because the increasing content of the methacrylic acid that aided processability resulted in a sharp decrease in the light output. The use of small amounts of methacrylic acid (≤3 wt.%) resulted in better performance but required high processing temperatures. At large scales, these high temperatures could initiate exothermic polymerization that results in premature curing and/or defects. The deleterious effects of the methacrylic acid may be mitigated by using m-terphenyl as a primary dye rather than 2,5-diphenyloxazole (PPO), which has been traditionally used in organic scintillators. Finally, the curing environment was controlled to avoid defects like cracking and discolouration while maintaining solubility of dopants during curing. For scintillators that were produced from kilogram-scale batches of precursors, the effective attenuation of scintillation light was characterized.
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we discuss the causes for such instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with O(1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.
The paper describes preparation of 6Li-loaded liquid scintillators by methods involving direct dissolution of 6Li salts in the commercial diisopropylnaphthalene (DIPN) solvent, without the formation of water-in-oil emulsions. Methods include incorporation of 6Li that, unlike previously reported formulations, does not require additions of water or a strong acid such as hydrochloric acid (HCl). Results of the conducted experiments show that dissolution of aromatic , aliphatic 6Li salts in DIPN can be easily achieved at 0.1%-0.3% by weight of atomic 6Li, using small additions of waterless surfactants, or mild carboxylic acids. An alternative way suggests incorporation of 6Li as a part of a surfactant molecule that can be dissolved in DIPN without any solubilizing additions. Proposed methods enable preparation of efficient 6Li-loaded liquid scintillators that, at a large scale of 50 cm, exhibit good pulse shape discrimination (PSD) properties combined with up to 107% of light output and up to 115% of the attenuation length measured relative to standard undoped EJ-309 liquid scintillator.
This Letter reports one of the most precise measurements to date of the antineutrino spectrum from a purely ^{235}U-fueled reactor, made with the final dataset from the PROSPECT-I detector at the High Flux Isotope Reactor. By extracting information from previously unused detector segments, this analysis effectively doubles the statistics of the previous PROSPECT measurement. The reconstructed energy spectrum is unfolded into antineutrino energy and compared with both the Huber-Mueller model and a spectrum from a commercial reactor burning multiple fuel isotopes. A local excess over the model is observed in the 5-7 MeV energy region. Comparison of the PROSPECT results with those from commercial reactors provides new constraints on the origin of this excess, disfavoring at 2.0 and 3.7 standard deviations the hypotheses that antineutrinos from ^{235}U are solely responsible and noncontributors to the excess observed at commercial reactors, respectively.
Nuclear reactors are uniquely powerful, abundant, and flavor-pure sources of antineutrinos that continue to play a vital role in the US neutrino physics program. The US reactor antineutrino physics community is a diverse interest group encompassing many detection technologies and many particle physics topics, including Standard Model and short-baseline oscillations, BSM physics searches, and reactor flux and spectrum modeling. The community's aims offer strong complimentary with numerous aspects of the wider US neutrino program and have direct relevance to most of the topical sub-groups composing the Snowmass 2021 Neutrino Frontier. Reactor neutrino experiments also have a direct societal impact and have become a strong workforce and technology development pipeline for DOE National Laboratories and universities. This white paper, prepared as a submission to the Snowmass 2021 community organizing exercise, will survey the state of the reactor antineutrino physics field and summarize the ways in which current and future reactor antineutrino experiments can play a critical role in advancing the field of particle physics in the next decade.
This report summarizes the current status of neutrino physics and the broad and exciting future prospects identified for the Neutrino Frontier as part of the 2021 Snowmass Process.
We discuss here new, enabling technologies for future photon-based neutrino detectors. These technologies touch nearly every aspect of such detectors: new scintillating materials, new methods of loading isotopes, new photon sensors and collectors, new approaches to simulation and analysis, and new front-end electronics and DAQ ideas. Of particular interest are technologies that enable broad physics programs in hybrid Cherenkov/scintillation detectors, such as slow fluors, water-based liquid scintillator, and spectral sorting of photons. Several new large-scale detector ideas are also discussed, including hybrid detectors like Theia, ArTEMIS, and generic slow-fluor detectors, as well as the very different SLIPs and LiquidO approaches to instrumenting photon-based detectors. A program of demonstrators for future detectors, including ANNIE, Eos, and NuDOT are also discussed.
This report has been prepared as part of the US Community Study on the Future of Particle Physics (Snowmass 2021) by the Snowmass Neutrino Frontier Topical Group NF07 Conveners, based on input from contributed White papers and Letters of Interest.
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is intended to provide an absolute normalization of the measured fission cross-section ratio. The Pu-239/U-235 atom number ratio was measured with a combination of mass spectrometry and alpha-spectroscopy with a planar silicon detector with uncertainties of less than 1%.