AbstractWe report the electrochemistry of a hitherto unexplored Na2MoS4 phase as a conversion electrode material for Na‐ and Li‐ion batteries. The material adopts an amorphous coordination polymer structure with mixed Mo and S valences. XPS and XRD analysis reveal a complex interplay between Mo and S redox chemistry, while excluding the formation of free sulfur, lithium sulfide, or other crystalline phases. Na2MoS4 behaves as a mixed ionic–electronic conductor, with electronic conductivity of 6.1×10−4 S cm−1, that permits carbon‐free application in an electrochemical cell. A reversible capacity of up to 500 mAh g−1 was attained, corresponding to a five‐electron redox exchange, with species ranging from <1MoS4> (highest oxidized state) to >5MoS4> (lowest oxidized state). This study emphasizes the excellent charge‐storage performances of Na2MoS4 for Li‐ or Na‐ion batteries, and enriches the emerging library and knowledge of sulfide phases with mixed anionic and cationic redox properties.
Wearables that continuously acquire medically relevant parameters can reduce duration of hospitalizations and derive treatment optimizations for individual patients thus improving the quality of medical treatments. We demonstrate an architecture that includes wearables, edge and cloud computing to provide optimal user interaction and analytics of multi-parameter wearable data to accomplish this goal. We also explore the trade-offs of on-wearable processing versus raw data transmission and the use of commercial location monitors to acquire indoor location data.
Novel heat removal and power delivery topologies are required to enable `extreme 3D integration' with cube-sized compute nodes. Therefore, a technology roadmap is presented supporting memory-on-logic and logic-on-logic in the medium and long-term, by (i) dual-side cooling and integrated voltage regulators, and (ii) interlayer cooling and electrochemical power delivery.
Membraneless flow cells for electrochemical energy conversion exploit the laminarity of microscale flows to avoid undesirable mixing of reactants. To increase the performance of microfluidic redox flow cells we employ herringbone-inspired flow promoters, thereby increasing convection of each individual species to the electrodes, while minimizing reactant mixing. Polarization curves from electrochemical discharge measurements with a dilute anthraquinone/iron redox system reveal that the presence of flow promoters substantially boosts device performance. Mass transfer enhancement for devices with flow promoters is demonstrated through both higher limiting currents and increased power density; the former is more than double compared to a plain reference microchannel for Reynolds numbers of Re >155. The chaotic mixing effect induced by the flow promoters also becomes apparent in the scaling regimes, the limiting currents are proportional to Re-0.58 instead of Re-1/3 (as for purely laminar flow). Further, we quantify the area specific resistance (ASR) of the electrolyte in our membraneless devices finding a reduction of more than one order of magnitude compared to the ASR of conventional membranes employed in redox flow cells. Overcoming mass transfer limitations, this work highlights the necessity of passive mixers in significantly raising the performance of microfluidic flow cells. (C) 2016 Elsevier Ltd. All rights reserved.
We propose a facile, novel concept of mass transfer enhancement in flow batteries based on electrolyte guidance in rationally designed corrugated channel systems. The proposed fluidic networks employ periodic throttling of the flow to optimally deflect the electrolytes into the porous electrode, targeting enhancement of the electrolyte-electrode interaction. Theoretical analysis is conducted with channels in the form of trapezoidal waves, confirming and detailing the mass transport enhancement mechanism. In dilute concentration experiments with an alkaline quinone redox chemistry, a scaling of the limiting current with Re0.74 is identified, which compares favourably against the Re0.33 scaling typical of diffusion-limited laminar processes. Experimental IR-corrected polarization curves are presented for high concentration conditions, and a significant performance improvement is observed with the narrowing of the nozzles. The adverse effects of periodic throttling on the pumping power are compared with the benefits in terms of power density, and an improvement of up to 102% in net power density is obtained in comparison with the flow-by case employing straight parallel channels. The proposed novel concept of corrugated fluidic networks comes with facile fabrication and contributes to the improvement of the transport characteristics and overall performance of redox flow battery systems.
The miniaturization of redox flow cells (RFCs) paves the way to novel energy conversion concepts combining power delivery and heat regulation. Envisioning the integration of high-power-density RFCs into electronic devices such as microprocessors, lasers, or light-emitting diodes for the purpose of providing power and heat management simultaneously, we introduce and investigate interdigitated, tapered multiple-pass microfluidic networks in miniaturized flow cells. Employing 3D-printing for the facile and inexpensive fabrication of these networks, we demonstrate RFCs with maximum power densities of up to 1.4 W cm−2 at room temperature and net power densities of up to 0.99 W cm−2 after subtracting pumping power losses. The electrolytes employed modest concentrations of 0.4 M K4Fe(CN)6 and 0.2 M 2,6-dihydroxyanthraquinone in alkaline electrolyte. We thereby show that rational tailoring of fluidic networks in RFCs is key for the development of devices effectively combining power delivery and thermal management.
Wearables that continuously acquire vital and other medically relevant parameters facilitate treatment optimizations for individual patients and reduce the duration of hospitalizations - thus improving the patients' quality of life. To accomplish this, we demonstrate a scalable architecture that connects wearables through a hub to the cloud, combines edge and cloud computing to provide optimal user interaction, and allows analytics on multi-stream data from those connected devices.
The electrochemical (EC) behavior of mechanically exfoliated graphene and highly oriented pyrolytic graphite (HOPG) is studied at high spatial resolution in aqueous solutions using Ru(NH3)6(3+/2+) as a redox probe whose standard potential sits close to the intrinsic Fermi level of graphene and graphite. When scanning electrochemical cell microscopy (SECCM) data are coupled with that from complementary techniques (AFM, micro-Raman) applied to the same sample area, different time-dependent EC activity between the basal planes and step edges is revealed. In contrast, other redox couples (ferrocene derivatives) whose potential is further removed from the intrinsic Fermi level of graphene and graphite show uniform and high activity (close to diffusion-control). Macroscopic voltammetric measurements in different environments reveal that the time-dependent behavior after HOPG cleavage, peculiar to Ru(NH3)6(3+/2+), is not associated particularly with any surface contaminants but is reasonably attributed to the spontaneous delamination of the HOPG with time to create partially coupled graphene layers, further supported by conductive AFM measurements. This process has a major impact on the density of states of graphene and graphite edges, particularly at the intrinsic Fermi level to which Ru(NH3)6(3+/2+) is most sensitive. Through the use of an improved voltammetric mode of SECCM, we produce movies of potential-resolved and spatially resolved HOPG activity, revealing how enhanced activity at step edges is a subtle effect for Ru(NH3)6(3+/2+). These latter studies allow us to propose a microscopic model to interpret the EC response of graphene (basal plane and edges) and aged HOPG considering the nontrivial electronic band structure.
The electrochemical (EC) oxidation of the neurotransmitter, serotonin, at individual single-walled carbon nanotubes (SWNTs) is investigated at high resolution using a novel platform that combines flow-aligned SWNTs with atomic force microscopy, Raman microscopy, electronic conductance measurements, individual SWNT electrochemistry and high-resolution scanning electrochemical cell microscopy (SECCM). SECCM has been used to visualise the EC activity along side-wall sections of metallic SWNTs to assess the extent to which side-walls promote the electrochemistry of this complex multi-step process. Uniform and high EC activity is observed that is consistent with significant reaction at the side-wall, rather than electrochemistry being driven by defects alone. By scanning forward and reverse (trace and retrace) over the same region of a SWNT, it is also possible to assess any blocking of EC activity by serotonin oxidation reaction products. At a physiologically relevant concentration (5 μM), there is no detectable blocking of SWNTs, which can be attributed, at least in part, to the high diffusion rate to an individual, isolated SWNT in the SECCM format. At higher serotonin concentration (2 mM), oligomer formation from oxidation products is much more significant and major blocking of the EC process is observed from line profiles recorded as the SECCM meniscus moves over an SWNT. The SECCM line profile morphology is shown to be highly diagnostic of whether blocking occurs during EC processes. The studies herein add to a growing body of evidence that various EC processes at SWNTs, from simple outer sphere redox reactions to complex multi-step processes, occur readily at pristine SWNTs. The platform described is of general applicability to various types of nanostructures and nanowires.
Scanning electrochemical cell microscopy (SECCM) is a new pipette-based imaging technique purposely designed to allow simultaneous electrochemical, conductance, and topographical visualization of surfaces and interfaces. SECCM uses a tiny meniscus or droplet, at the end of a double-barreled (theta) pipette, for high-resolution functional imaging and nanoscale electrochemical measurements. Here we introduce this technique and provide an overview of its principles, instrumentation, and theory. We discuss the power of SECCM in resolving complex structure-activity problems and provide considerable new information on electrode processes by referring to key example systems, including graphene, graphite, carbon nanotubes, nanoparticles, and conducting diamond. The many longstanding questions that SECCM has been able to answer during its short existence demonstrate its potential to become a major technique in electrochemistry and interfacial science.
By incorporating a localized heating system within a scanning ion-conductance microscopy (SICM) system, we have performed stable ‘hopping-mode’ (HPICM) imaging for live cells maintained at temperatures ranging up to human body temperature. This allows the accurate study of cell volume and morphology variation versus temperature over extended periods of time. The integration of SICM with scanning electrochemical microscopy (SECM) provides the simultaneous mapping of electrochemical and topographic information for soft samples, such as live cells. This combined technique overcomes the limitations of resolution and topographical artifacts typically associated with SECM. However, previously reported SECM-SICM probe production required expensive and time-consuming focused ion beam (FIB) methods and produced pipettes that are typically hundreds of nanometers in diameter. We report a simple and rapid production method for SECM-SICM double-barrel probes with apertures down to 20 nm in diameter. The characterization of these SECM-SICM probes using scanning electron microscopy (SEM) imaging, cyclic voltammetry (CV) and Raman spectroscopy is also detailed. These SECM-SICM probes were subsequently used to study the morphology and electrochemical activity of several samples, ranging from hard metallic/insulating samples to live cells.
The electrochemical properties of the closed ends and sidewalls of pristine carbon nanotube forests are investigated directly using a nanopipet electrochemical cell. Both are shown to promote fast electron transfer, without any activation or processing of the carbon nanotube material required, in contrast to the current model in the literature.
As a new form of carbon, graphene is attracting intense interest as an electrode material with widespread applications. In the present study, the heterogeneous electron transfer (ET) activity of graphene is investigated using scanning electrochemical cell microscopy (SECCM), which allows electrochemical currents to be mapped at high spatial resolution across a surface for correlation with the corresponding structure and properties of the graphene surface. We establish that the rate of heterogeneous ET at graphene increases systematically with the number of graphene layers, and show that the stacking in multilayers also has a subtle influence on ET kinetics.
Scanning electrochemical cell microscopy (SECCM) is a high resolution electrochemical scanning probe technique that employs a dual-barrel theta pipet probe containing electrolyte solution and quasi-reference counter electrodes (QRCE) in each barrel. A thin layer of electrolyte protruding from the tip of the pipet ensures that a gentle meniscus contact is made with a substrate surface, which defines the active surface area of an electrochemical cell. The substrate can be an electrical conductor, semiconductor, or insulator. The main focus here is on the general case where the substrate is a working electrode, and both ion-conductance measurements between the QRCEs in the two barrels and voltammetric/amperometric measurements at the substrate can be made simultaneously. In usual practice, a small perpendicular oscillation of the probe with respect to the substrate is employed, so that an alternating conductance current (ac) develops, due to the change in the dimensions of the electrolyte contact (and hence resistance), as well as the direct conductance current (dc). It is shown that the dc current can be predicted for a fixed probe by solving the Nernst-Planck equation and that the ac response can also be derived from this response. Both responses are shown to agree well with experiment. It is found that the pipet geometry plays an important role in controlling the dc conductance current and that this is easily measured by microscopy. A key feature of SECCM is that mass transport to the substrate surface is by diffusion and, for charged analytes, ion migration which can be controlled and varied quantifiably via the bias between the two QRCEs. For a working electrode substrate this means that charged redox-active analytes can be transported to the electrode/solution interface in a well-defined and controllable manner and that relatively fast heterogeneous electron transfer kinetics can be studied. The factors controlling the voltammetric response are determined by both simulation and experiment. Experiments demonstrate the realization of simultaneous quantitative voltammetric and ion conductance measurements and also identify a general rule of thumb that the surface contacted by electrolyte is of the order of the pipet probe dimensions.
Carbon nanotubes have attracted considerable interest for electrochemical, electrocatalytic, and sensing applications, yet there remains uncertainty concerning the intrinsic electrochemical (EC) activity. In this study, we use scanning electrochemical cell microscopy (SECCM) to determine local heterogeneous electron transfer (HET) kinetics in a random 2D network of single-walled carbon nanotubes (SWNTs) on an Si/SiO 2 substrate. The high spatial resolution of SECCM, which employs a mobile nanoscale EC cell as a probe for imaging, enables us to sample the responses of individual portions of a wide range of SWNTs within this complex arrangement. Using two redox processes, the oxidation of ferrocenylmethyl trimethylammonium and the reduction of ruthenium (III) hexaamine, we have obtained conclusive evidence for the high intrinsic EC activity of the sidewalls of the large majority of SWNTs in networks. Moreover, we show that the ends of SWNTs and the points where two SWNTs cross do not show appreciably different HET kinetics relative to the sidewall. Using finite element method modeling, we deduce standard rate constants for the two redox couples and demonstrate that HET based solely on characteristic defects in the SWNT side wall is highly unlikely. This is further confirmed by the analysis of individual line profiles taken as the SECCM probe scans over an SWNT. More generally, the studies herein demonstrate SECCM to be a powerful and versatile method for activity mapping of complex electrode materials under conditions of high mass transport, where kinetic assignments can be made with confidence.
In the bottom part of Figure 2 b of this Communication, the scale of the vertical axis is wrong. the correct Figure is shown here. Approach curves of a DBCNP for simultaneous ion current (top) and electrochemical (bottom) measurements on an insulating (a) and conductive (b) substrate in 1.0 mm FcCH2OH+PBS. The SECM and SICM electrodes were held at 500 and 200 mV versus a reference Ag/AgCl electrode, respectively. The RG value used for the theoretical curves was 1.5.