Assuming the existence of axion-like particles (ALPs), the standard Quantum Electrodynamics (QED) amplitudes for the linear Breit-Wheeler (BW) pair production process are shown to be supplemented by an additional ALP-mediated amplitude. We compute the coherently combined cross section and show that, for pseudoscalar ALPs, interference with QED produces an asymmetric Fano-type resonance. We propose experimental observation of the BW process with real photons as a complementary probe of MeV-scale ALPs, coupling jointly with photons and electron-positron pairs, on the basis that it occupies a kinematic region not readily accessible to other ALP search methods.
Radiation reaction, the force experienced by an accelerated charge due to radiation emission, has long been the subject of extensive theoretical and experimental research. Experimental verification of a quantum, strong-field description of radiation reaction is fundamentally important, and has wide-ranging implications for astrophysics, laser-driven particle acceleration, next-generation particle colliders and inverse-Compton photon sources for medical and industrial applications. However, the difficulty of accessing regimes where strong field and quantum effects dominate inhibited previous efforts to observe quantum radiation reaction in charged particle dynamics with high significance. We report a high significance ( > 5σ) observation of strong-field radiation reaction on electron spectra where quantum effects are substantial. We obtain quantitative, strong evidence favouring the quantum-continuous and quantum-stochastic models over the classical model; the quantum models perform comparably. The lower electron energy losses predicted by the quantum models account for their improved performance. Model comparison was performed using a novel Bayesian framework, which has widespread utility for laser-particle collision experiments, including those utilising conventional accelerators, where some collision parameters cannot be measured directly.
Recent experiments aiming to measure phenomena predicted by strong-field quantum electrodynamics(SFQED) have done so by colliding relativistic electron beams and high-power lasers. In such experiments, measurements of collision parameters are not always feasible. However, precise knowledge of these parameters is required to accurately test SFQED.Here, we present a novel Bayesian inference procedure that infers collision parameters that could not be measured on-shot. This procedure is applicable to all-optical non-linear Compton scattering experiments investigating radiation reaction. The framework allows multiple diagnostics to be combined self-consistently and facilitates the inclusion of known information pertaining to the collision parameters. Using this Bayesian analysis, the relative validity of the classical, quantum-continuous and quantum-stochastic models of radiation reaction was compared for several test cases,which demonstrates the accuracy and model selection capability of the framework and highlight its robustness if the experimental values of fixed parameters differ from their values in the models.
Understanding dense matter hydrodynamics is critical for predicting plasma behavior in environments relevant to laser-driven inertial confinement fusion. Traditional diagnostic sources face limitations in brightness, spatiotemporal resolution, and in their ability to detect relevant electromagnetic fields. In this work, we present a dual-probe, multi-messenger laser wakefield accelerator platform combining ultrafast X-rays and relativistic electron beams at 1 Hz, to interrogate a free-flowing water target in vacuum, heated by an intense 200 ps laser pulse. This scheme enables high-repetition-rate tracking the evolution of the interaction using both particle types. Betatron X-rays reveal a cylindrically symmetric shock compression morphology assisted by low-density vapor, resembling foam-layer-assisted fusion targets. The synchronized electron beam detects time-evolving electromagnetic fields, uncovering charge separation and ion species differentiation during plasma expansion - phenomena not captured by photons or hydrodynamic simulations. We show that combining both probes provides complementary insights spanning kinetic to hydrodynamic regimes, highlighting the need for hybrid physics models to accurately predict fusion-relevant plasma behavior.
The rapid progress that plasma wakefield accelerators are experiencing is now posing the question as to whether they could be included in the design of the next generation of high-energy electron-positron colliders. However, the typical structure of the accelerating wakefields presents challenging complications for positron acceleration. Research in plasma-based acceleration of positrons has thus far experienced limited experimental progress due to the lack of positron beams suitable to seed a plasma accelerator. Here, we report on the first experimental demonstration of a laser-driven source of ultra-relativistic positrons with sufficient spectral and spatial quality to be injected in a plasma accelerator. Our results indicate, in agreement with numerical simulations, selection and transport of positron beamlets containing $N_{e+}\geq10^5$ positrons in a 5\% bandwidth around 600 MeV, with femtosecond-scale duration and micron-scale normalised emittance. Particle-in-cell simulations show that positron beams of this kind can be efficiently guided and accelerated in a laser-driven plasma accelerator, with favourable scalings to further increase overall charge and energy using PW-scale lasers. The results presented here demonstrate the possibility of performing experimental studies of positron acceleration in a plasma wakefield.
Laser-driven compact particle accelerators can provide ultrashort pulses of broadband X-rays, well suited for undertaking X-ray absorption spectroscopy measurements on a femtosecond timescale. Here the Extended X-ray Absorption Fine Structure (EXAFS) features of the K-edge of a copper sample have been observed over a 250 eV window in a single shot using a laser wakefield accelerator, providing information on both the electronic and ionic structure simultaneously. This capability will allow the investigation of ultrafast processes, and in particular, probing high-energy-density matter and physics far-from-equilibrium where the sample refresh rate is slow and shot number is limited. For example, states that replicate the tremendous pressures and temperatures of planetary bodies or the conditions inside nuclear fusion reactions. Using high-power lasers to pump these samples also has the advantage of being inherently synchronised to the laser-driven X-ray probe. A perspective on the additional strengths of a laboratory-based ultrafast X-ray absorption source is presented. Laser-driven X-rays can provide ultrashort pulses of broadband light, well suited for femtosecond timescale absorption spectroscopy. Here the authors measure the extended X-ray absorption features of a copper sample using a laser wakefield accelerator, in a single shot; important for studying samples driven to extreme and non-equilibrium states.
We report on the first experimental characterization of a laser-wakefield accelerator able to deliver, in a single pulse, doses in excess of [1]Gy on timescales of the order of a hundred femtoseconds, reaching unprecedented average dose-rates up to [10^13]Gy/s. The irradiator is demonstrated to deliver doses tuneable up to [2.2]Gy in a cm^2 area and with a high degree of longitudinal and transverse uniformity in a single irradiation. In this regime, proof-of-principle irradiation of patient-derived glioblastoma stem-like cells and human skin fibroblast cells show indications of a differential cellular response, when compared to reference irradiations at conventional dose-rates. These include a statistically significant increase in relative biological effectiveness (1.40±0.08 at 50% survival for both cell lines) and a significant reduction of the relative radioresistance of tumour cells. Data analysis provides preliminary indications that these effects might not be fully explained by induced oxygen depletion in the cells but may be instead linked to a higher complexity of the damages triggered by the ultra-high density of ionising tracks of femtosecond-scale radiation pulses. These results demonstrate an integrated platform for systematic radiobiological studies at unprecedented beam durations and dose-rates, a unique infrastructure for translational research in radiobiology at the femtosecond scale.
The collision of a high-energy electron beam with a laser pulse may be used to study radiation reaction and nonlinear Compton scattering among many other processes in strong-field quantum electrodynamics. Predictions from simulation and theory for these interactions rely on a number of approximations and assumptions that have not been experimentally tested. Here, experimentally measurable signatures are identified that might be able to distinguish between radiation reaction models, i.e., classical or quantum, or between the local constant field and local monochromatic approximations used to calculate the properties of the nonlinear Compton process. These signatures are considered through Monte Carlo simulations of various experimental conditions that are relevant to today's laser facilities. Potential detection schemes for measuring the signatures are proposed. We find that single-photon counting of keV photons to resolve harmonics and scintillator-based detection of MeV photons may allow us to validate nonlinear Compton scattering models and radiation reaction models respectively. This will require electron beams with divergence angles less than 2 mrad and less than 20% energy spread.
Experiments were performed on laser wakefield acceleration in the highly nonlinear regime. With laser powers P<250 TW and using an initial spot size larger than the matched spot size for guiding, we were able to accelerate electrons to energies Emax>2.5 GeV, in fields exceeding 500 GV m−1, with more than 80 pC of charge at energies E>1 GeV. Three-dimensional particle-in-cell simulations show that using an oversized spot delays injection, avoiding beam loss as the wakefield undergoes length oscillation. This enables injected electrons to remain in the regions of highest accelerating fields and leads to a doubling of energy gain as compared to results from using half the focal length with the same laser. Published by the American Physical Society 2024
While plasma-based accelerators have the potential to positively impact a broad range of research topics, a route to application will only be possible through improved understanding of their stability. We present experimental results of a laser wakefield accelerator in the nonlinear regime in a helium gas jet target with a density transition produced by a razor blade in the flow. Modifications to the target setup are correlated with variations in the plasma density profile diagnosed via interferometry and the shot-to-shot variations of the density profile for nominally equal conditions are characterized. Through an in-depth sensitivity study using particle-in-cell simulations, the effects of changes in the plasma density profile on the accelerated electron beams are investigated. The results suggest that blade motion is more detrimental to stability than gas pressure fluctuations, and that early focusing of the laser may reduce the deleterious effects of such density fluctuations.
We report on an experimental observation of the streaking of betatron x rays in a curved laser wakefield accelerator. The streaking of the betatron x rays was realized by launching a laser pulse into a plasma with a transverse density gradient. By controlling the plasma density and the density gradient, we realized the steering of the laser driver, electron beam, and betatron x rays simultaneously. Moreover, we observed an energy-angle correlation of the streaked betatron x rays and utilized it in diagnosing the electron acceleration process in a single-shot mode. Our work could also find applications in advanced control of laser beam and particle propagation. More importantly, the angular streaked betatron x ray has an intrinsic spatiotemporal correlation, which makes it a promising tool for single-shot pump-probe applications.
Current experiments investigating radiation reaction employ high energy electron beams together with tightly focused laser pulses in order to reach the quantum regime, as expressed through the quantum nonlinearity parameter $\chi$. Such experiments are often complicated by the large number of latent variables, including the precise structure of the electron bunch. Here we examine a correlation between the electron spatial and energy distributions, called an energy chirp, investigate its significance to the laser-electron beam interaction and show that the resulting effect cannot be trivially ignored when analysing current experiments. In particular, we show that the energy chirp has a large effect on the second moment of the electron energy, but a lesser impact on the first electron energy moment or the photon critical energy. These results show the importance of improved characterisation and control over electron bunch parameters on a shot-to-shot basis in such experiments.
This project funded one graduate student, Mario Balcazar, to perform experiments on high power laser facilities to study the application of X-rays generated by laser wakefield accelerated electrons for advanced radiography, in particular X-ray phase contrast imaging of hydrodynamic shocks/instabilities. The work made use of the DOE’s LaserNetUS facilities. We performed dynamic phase-contrast X-ray imaging of the shock generated by a 200 ps duration laser pulse (E = 1 J, I = 1015 Wcm–2) with a 30 µm diameter liquid target, with unprecedented spatio-temporal resolution. This includes multi-shock generation within the liquid jet and plasma instability formation. Innovative electron-beam radiography was used to probe the laser-plasma interplay finding evidence of bilateral heating of the water followed by strong electric field generation. These measurements help explain some of the discrepancies between simulation and experiment and pave the way to better plasma diagnostic systems in HED and ICF physics experiments. This work was performed in collaboration with researchers from Michigan, LLNL, LBL and Sandia National Laboratories, Queen’s University Belfast and Imperial College.
The data contained in this repository was used in the production of the publication "X-ray absorption spectroscopy using an ultrafast laboratory-scale laser-plasma accelerator source"
A machine learning model was created to predict the electron spectrum generated by a GeV-class laser wakefield accelerator. The model was constructed from variational convolutional neural networks, which mapped the results of secondary laser and plasma diagnostics to the generated electron spectrum. An ensemble of trained networks was used to predict the electron spectrum and to provide an estimation of the uncertainty of that prediction. It is anticipated that this approach will be useful for inferring the electron spectrum prior to undergoing any process that can alter or destroy the beam. In addition, the model provides insight into the scaling of electron beam properties due to stochastic fluctuations in the laser energy and plasma electron density.
A linear Breit-Wheeler module for the code GEANT4 has been developed. This allows signal-to-noise ratio calculations of linear Breit-Wheeler detection experiments to be performed within a single framework. The interaction between two photon sources is modeled by treating one as a static field, then photons from the second source are sampled and tracked through the field. To increase the efficiency of the module, we have used a Gaussian process regression, which can lead to an increase in the calculation rate by a factor of up to 1000. To demonstrate the capabilities of this module, we use it to perform a parameter scan, modeling an experiment based on that recently reported by Kettle et al. [New J. Phys. 23, 115006 (2021)]. We show that colliding 50-fs duration gamma rays, produced through bremsstrahlung emission of a 100 pC, 2-GeV laser wakefield accelerator beam, with a 50-ps x-ray field, generated by a germanium burn-through foil heated to temperatures >150 eV, this experiment is capable of producing > 1 Breit-Wheeler pair per shot.
We have carried out a series of experiments to measure the Cl K-absorption edge for shock-compressed samples of chlorinated parylene. Colliding shocks allowed us to compress samples up to four times the initial density with temperatures up to 10 eV. Red shifts in the edge of about 10 eV have been measured. We have compared the measured shifts to analytical modelling using the Stewart–Pyatt model and adaptions of it, combined with estimates of density and temperature based on hydrodynamic modelling. Modelling of the edge position using density functional theory molecular dynamics (DFT-MD) was also used and it was found that good agreement was only achieved when the DFT simulations assumed conditions of lower temperature and slightly higher density than indicated by hydrodynamic simulations using a tabular equation of state.
A common goal of undergraduate physics laboratory classes is for students to gain experience in the ways of thinking like an experimental physicist when designing experiments, taking measurements, performing analysis, and communicating results. Whether or not students actually develop more expert-like ways of thinking by the end of their degree remains an outstanding question. In this work, we describe a longitudinal study to answer that question using the Colorado Learning Attitudes about Science Survey for Experimental Physics (E-CLASS). As a preliminary exercise, we make explicit our expectations for the results of the longitudinal study, so that in the future we may critically analyse the results while being conscious of our own biases.
The dataset and analysis codes for the publication "Characterisation of Laser Wakefield Acceleration Efficiency with Octave Spanning Near-IR Spectrum Measurements". Analysis code is stored as jupyter notebooks.
Figure 20.1 was not correct in the published article. The original article has been corrected. The published apologizes for the inconvenience.