Figure 20.1 was not correct in the published article. The original article has been corrected. The published apologizes for the inconvenience.
This paper describes the utilization of beam-driven plasma wakefield acceleration to implement a high-quality plasma cathode via density-downramp injection in a short injector stage at the FLASHForward facility at DESY. Electron beams with charge of up to 105 pC and energy spread of a few percent were accelerated by a tunable effective accelerating field of up to 2.7 GV/m. The plasma cathode was operated drift-free with very high injection efficiency. Sources of jitter, the emittance and divergence of the resulting beam were investigated and modeled, as were strategies for performance improvements that would further increase the wide-ranging applications for a plasma cathode with the demonstrated operational stability
Energy-efficient plasma-wakefield acceleration of particle bunches with low energy spread is a promising path to realizing compact free-electron lasers and particle colliders. High efficiency and low energy spread can be achieved simultaneously by strong beam loading of plasma wakefields when accelerating bunches with carefully tailored current profiles [M. Tzoufras et al., Phys. Rev. Lett. 101, 145002 (2008)PRLTAO0031-900710.1103/PhysRevLett.101.145002]. We experimentally demonstrate such optimal beam loading in a nonlinear electron-driven plasma accelerator. Bunches with an initial energy of 1 GeV were accelerated by 45 MeV with an energy-transfer efficiency of (42±4)% at a gradient of 1.3 GV/m while preserving per-mille energy spreads with full charge coupling, demonstrating wakefield flattening at the few-percent level.
A Correction to this paper has been published: https://doi.org/10.1038/s41467-020-20676-1
This report presents the conceptual design of a new European research infrastructure EuPRAXIA. The concept has been established over the last four years in a unique collaboration of 41 laboratories within a Horizon 2020 design study funded by the European Union. EuPRAXIA is the first European project that develops a dedicated particle accelerator research infrastructure based on novel plasma acceleration concepts and laser technology. It focuses on the development of electron accelerators and underlying technologies, their user communities, and the exploitation of existing accelerator infrastructures in Europe. EuPRAXIA has involved, amongst others, the international laser community and industry to build links and bridges with accelerator science - through realising synergies, identifying disruptive ideas, innovating, and fostering knowledge exchange. The Eu-PRAXIA project aims at the construction of an innovative electron accelerator using laser- and electron-beam-driven plasma wakefield acceleration that offers a significant reduction in size and possible savings in cost over current state-of-the-art radiofrequency-based accelerators. The foreseen electron energy range of one to five gigaelectronvolts (GeV) and its performance goals will enable versatile applications in various domains, e.g. as a compact free-electron laser (FEL), compact sources for medical imaging and positron generation, table-top test beams for particle detectors, as well as deeply penetrating X-ray and gamma-ray sources for material testing. EuPRAXIA is designed to be the required stepping stone to possible future plasma-based facilities, such as linear colliders at the high-energy physics (HEP) energy frontier. Consistent with a high-confidence approach, the project includes measures to retire risk by establishing scaled technology demonstrators. This report includes preliminary models for project implementation, cost and schedule that would allow operation of the full Eu-PRAXIA facility within 8-10 years.
Beam-driven plasma-wakefield acceleration based on external injection has the potential to significantly reduce the size of future accelerators. Stability and quality of the acceleration process substantially depends on the incoming bunch parameters. Precise control of the current profile is essential for optimising energy-transfer efficiency and preserving energy spread. At the FLASHForward facility, driver--witness bunch pairs of adjustable bunch length and separation are generated by a set of collimators in a dispersive section, which enables fs-level control of the longitudinal bunch profile. The design of the collimator apparatus and its commissioning is presented.
The FLASHForward experimental facility is a high-performance test-bed for precision plasma wakefield research, aiming to accelerate high-quality electron beams to GeV-levels in a few centimetres of ionized gas. The plasma is created by ionizing gas in a gas cell either by a high-voltage discharge or a high-intensity laser pulse. The electrons to be accelerated will either be injected internally from the plasma background or externally from the FLASH superconducting RF front end. In both cases, the wakefield will be driven by electron beams provided by the FLASH gun and linac modules operating with a 10 Hz macro-pulse structure, generating 1.25 GeV, 1 nC electron bunches at up to 3 MHz micro-pulse repetition rates. At full capacity, this FLASH bunch-train structure corresponds to 30 kW of average power, orders of magnitude higher than drivers available to other state-of-the-art LWFA and PWFA experiments. This high-power functionality means FLASHForward is the only plasma wakefield facility in the world with the immediate capability to develop, explore and benchmark high-average-power plasma wakefield research essential for next-generation facilities. The operational parameters and technical highlights of the experiment are discussed, as well as the scientific goals and high-average-power outlook. This article is part of the Theo Murphy meeting issue 'Directions in particle beam-driven plasma wakefield acceleration'.
A collaboration between DESY, PSI and CERN has been established to develop and build an advanced modular Xband transverse deflection structure (TDS) system with the new feature of providing variable polarization of the deflecting force. The prototype of the novel X-band TDS, the Polarizable X-band (PolariX) TDS, was fabricated at PSI following the high-precision tuning-free production process developed for the C-band Linac of the SwissFEL project. Bead-pull RF measurements were also performed at PSI to verify, in particular, that the polarization of the dipole fields does not have any rotation along the structure. The highpower test was performed at CERN and now the TDS is at DESY and has been installed in FLASHForward, where the first streaking experience with beam will be accomplished. We summarize in this paper the status of the project, the results of the bead-pull measurements and the high power test. INTRODUCTION Several experiments at DESY (FLASH2, FLASHForward, SINBAD) and PSI (ATHOS at SwissFEL) are interested in the utilization of high gradient X-band TDS systems for high resolution longitudinal diagnostics [1]. In this context, a collaboration between DESY, PSI and CERN has been established to develop and build an advanced modular X-Band TDS system with the new feature of providing variable polarization of the deflecting force [2]. The prototype of the novel X-band TDS, the Polarizable X-band (PolariX) TDS, has been fabricated at PSI following the high-precision tuning-free production process developed for the C-band Linac of the SwissFEL project and already used for the fabrication of the tuning-free X-band structure prototypes for CLIC [3–5]. Bead-pull RF measurements has been performed at PSI between December 2018 and January 2019 in order to verify that the polarization of the dipole fields does not have any rotation along the structure. Figure 1 shows the detail of the input and output couplers (left), the whole TDS prototype (middle) and the basic disk geometry (right). The main RF parameters of the TDS and RF pulse ∗ paolo.craievich@psi.ch compressor are summarized in Table 1. High power test on the prototype has been performed at CERN between March and April 2019. In this paper we summarize the status of the collaboration focusing on the results of the bead-pull measurements and the high power tests. Figure 1: Left: detail of the input/output coupler. Middle: whole TDS prototype. Right: basic disk. BEAD-PULL MEASUREMENTS The dipole field flatness and polarization were measured with the bead-pull method. The structure was allocated in a vertical frame and a stepper motor was used to drive along the structure a 2 mm diameter dielectric sphere fixed to a dielectric wire with diameter of 0.16 mm. The bead pulling has been repeated for different offsets, both in the XZ and YZ planes, in ±2 mm range. The measurements were performed with a 4-port VNA and the reflection coefficient resulted to be less than −35 dB with an insertion loss of −5.5 dB. Figure 2 (upper plot) shows results of the bead-pull measurement with offset 0 mm both in X and Y and phase difference between ports of 0 deg. Cell-to-cell phase advance (lower plot) resulted to be 2π/3 with a dispersion of 0.8∘ rms at the working frequency of 11995.2 MHz with a temperature of 33.9∘C. It is worthwhile noting that same results for the phase ad-vance was obtained varying the relative phase between ports, namely for different polarizations. A spherical and dielectric bead perturbs only the electric field, but cannot distinguish between longitudinal and transverse components. However, since the longitudinal component has the largest 39th Free Electron Laser Conf. FEL2019, Hamburg, Germany JACoW Publishing ISBN: 978-3-95450-210-3 doi:10.18429/JACoW-FEL2019-WEP036
Plasma accelerators present one of the most suitable candidates for the development of more compact particle acceleration technologies, yet they still lag behind radiofrequency (RF)-based devices when it comes to beam quality, control, stability and power efficiency. The Horizon 2020-funded project EuPRAXIA ("European Plasma Research Accelerator with eXcellence In Applications") aims to overcome the first three of these hurdles by developing a conceptual design for a first international user facility based on plasma acceleration. In this paper we report on the main features, simulation studies and potential applications of this future research infrastructure.
The Horizon 2020 project EuPRAXIA (European Plasma Research Accelerator with eXcellence In Applications) is producing a conceptual design report for a highly compact and cost-effective European facility with multi-GeV electron beams accelerated using plasmas. EuPRAXIA will be set up as a distributed Open Innovation platform with two construction sites, one with a focus on beam-driven plasma acceleration (PWFA) and another site with a focus on laser-driven plasma acceleration (LWFA). User areas at both sites will provide access to free-electron laser pilot experiments, positron generation and acceleration, compact radiation sources, and test beams for high-energy physics detector development. Support centres in four different countries will complement the pan-European implementation of this infrastructure.
The EuPRAXIA project aims at designing the world's first accelerator based on advanced plasma-wakefield techniques to deliver 5 GeV electron beams that simultaneously have high charge, low emittance and low energy spread, which are required for applications by future user communities. Meeting this challenging objective will only be possible through dedicated effort. Many injection/acceleration schemes and techniques have been explored by means of thorough simulations in more than ten European research institutes. This enables selection of the most appropriate methods for solving each particular problem. The specific challenge of generating, extracting and transporting high charge beams, while maintaining the high quality needed for user applications, are being tackled using innovative approaches. This article highlights preliminary results obtained by the EuPRAXIA collaboration, which also exhibit the required laser and plasma parameters.
A tunable plasma-based energy dechirper has been developed at FLASHForward to remove the correlated energy spread of a 681 MeV electron bunch. Through the interaction of the bunch with wakefields excited in plasma the projected energy spread was reduced from a FWHM of 1.31% to 0.33% without reducing the stability of the incoming beam. The experimental results for variable plasma density are in good agreement with analytic predictions and three-dimensional simulations. The proof-of-principle dechirping strength of 1.8 GeV/mm/m significantly exceeds those demonstrated for competing state-of-the-art techniques and may be key to future plasma wakefield-based free-electron lasers and high energy physics facilities, where large intrinsic chirps need to be removed.
Density modulations in plasma caused by a high-intensity laser or a high charge density electron pulse can generate extreme acceleration fields. Acceleration of electrons in such fields may produce ultra-relativistic, quasi-monoenergetic, ultra-short electron bunches over distances orders of magnitudes shorter than in state-of-the-art radio-frequency accelerators. FLASHForward is a beam-driven plasma wakefield accelerator (PWFA) project at DESY with the goal of producing, characterizing, and utilizing such beams. Temporal characterization of the acceleration process is of crucial importance for improving the stability and control in PWFA beams. While measurement of the transient field of the femtosecond bunch in a single shot is challenging, in recent years novel techniques with great promise have been developed [1, 2]. This work discusses the plans and status of the transverse diagnostics at FLASHForward.
Beam quality preservation in the external injection scheme is one of the key missing milestones towards staging of plasma-wakefield accelerators, a prerequisite for their utilisation in particle physics or other applications requiring high energy beams. This topic will be studied at FLASHForward, a unique beam-driven plasma wakefield acceleration facility currently under construction at DESY (Hamburg, Germany), in the frame of the FLASHForward X-2 experiment. High-quality 1 GeV-class electron beams from the free-electron laser FLASH with. mu m-emittances, kA-scale currents, and less than 100 fs durations will be utilised to generate driver-witness pairs by using a mask in a dispersive section. In this contribution the physics case and the current status of the FLASHForward X-2 experiment are reviewed. The experimental installation is described, with a focus on the electron beamline. Electron beam dynamics and particle-in-cell simulations are presented.
Active plasma lenses have the potential to enable broad-ranging applications of plasma-based accelerators owing to their compact design and radially symmetric kT/m-level focusing fields, facilitating beam-quality preservation and compact beam transport. We report on the direct measurement of magnetic field gradients in active plasma lenses and demonstrate their impact on the emittance of a charged particle beam. This is made possible by the use of a well-characterized electron beam with 1.4 mm mrad normalized emittance from a conventional accelerator. Field gradients of up to 823 T/m are investigated. The observed emittance evolution is supported by numerical simulations, which suggests the potential for conservation of the core beam emittance in such a plasma lens setup.
A collaboration between DESY, PSI and CERN has been established to develop and build an advanced modular Xband transverse deflection structure (TDS) system with the new feature of providing variable polarization of the deflecting force. This innovative CERN design requires very high manufacturing precision to guarantee highest azimuthal symmetry of the structure to avoid the deterioration of the polarization of the streaking field. Therefore, the high-precision tuning-free production process developed at PSI for the Cband and X-band accelerating structures will be used for the manufacturing. We summarize in this paper the status of the production of the prototype and the waveguide networks foreseen in the different facilities.