Bioabsorbable metallic alloys constitute a very challenging and innovative field, mainly aimed to develop the next generation of temporary medical implants. Degradation data, biological in vitro and in vivo tests are of major importance in particular for complex alloys, in which the individual element additions could enhance material performance and add functionalities. In this study, a novel Fe-Mn-Si-Cu alloy was carefully designed for vascular and blood-contact applications, and its microstructure, mechanical behavior, degradation behavior and biological performances were investigated accordingly. In previous studies, Mn and Si were found to be suitable elements to effectively enhance mechanical properties and accelerate corrosion rate in simulated body fluid. Cu was added for further grain refinement by the formation of small Cu-rich particles, potentially impacting mechanical properties and degradation behavior. In addition, the feasibility of inducing antibacterial effects in a Fe-Mn-Si-Cu alloy with low Cu content was investigated. The alloy was prepared firstly on a small scale by vacuum arc remelting, then on a larger scale by vacuum induction melting and converted into sheets by conventional thermomechanical processing techniques. Heat treatments were explored to find optimal microstructure conditions. The results confirm promising mechanical, degradation and biological performance in testing the material in in vitro conditions, showing that the degradation products are neither systematically cytotoxic nor have any hemotoxic effects. On the other hand, the expected antibacterial effects could not be confirmed.
Biodegradable metals constitute a new class of materials for medical application. By breaking the paradigm that a metallic biomaterial to be implanted in the body must be corrosion resistant, biodegradable metals advance surgery allowing clinicians to dispose of temporary devices. Among them, Fe-Mn-C steel has emerged due to its outstanding mechanical properties, while its degradation rate must be carefully controlled. For this purpose, especially for medical devices, the surface finishing plays a pivotal role and influences both the corrosion behavior and biological response of these materials. Therefore, this research investigated the impact of electropolishing (EP) processes on the Fe-Mn-C alloy surface finishing in terms of composition, morphology, topography, and wettability. Three electrolytes were carefully selected and used in this study: EP1 (ethanol, perchloric acid, and glycerol), EP2 (perchloric acid, acetic acid, and glycerol), and an ionic liquid EP3 (choline chloride and ethylene glycol). Corrosion behavior and cell viability were investigated and compared with those obtained on mechanically polished (MP) samples. The results displayed that electropolishing was governed by two mechanisms: 1) controlled mass transport for EP1 and EP2, and 2) an adsorption mechanism for EP3. Among the tested conditions, EP2 emerged as a promising overall EP process. It promoted the smoothest and most hydrophilic passivated surface (Ra similar to 10 nm, WCA = 53 degrees, respectively) and the highest ratio of metal oxides to metallic elements. In addition, EP2 exhibited appropriate corrosion behavior suitable for biodegradable metal devices by inducing the formation of a protective oxide layer. Furthermore, cell viability with EP2 was comparable to that observed with MP. These findings emphasize the potential of electropolishing for enhancing the properties of Fe-Mn-C alloys, paving their applicability, especially in cardiovascular devices.
Poly(vinyl chloride) (PVC), a synthetic polymer, is used in various biomedical applications, particularly in the development of catheters. PVC-based catheters are engineered for blood-contacting applications. However, these materials lack antimicrobial properties, resulting in bacterial proliferation and subsequent infections. To overcome this disadvantage, blood-compatible and antimicrobial polyphenolic tannin-based surface coatings, known as polyelectrolyte multilayers (PEMs), were adsorbed onto PVC for the first time. PEMs were created on reduced PVC (Red-PVC) or oxidized PVC (Oxi-PVC) substrates using the layer-by-layer (LbL) approach. An aminofunctionalized polyphenolic tannin derivative (TN-NH2), commercially known as Tanfloc, and an unmodified polyphenolic tannin (TN), commercially known as Weibull black, were assembled (15 layers) on Oxi-PVC or RedPVC at pH 5.0. PVC substrates and PEMs were characterized through atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and water contact angle (WCA) measurements. The PEMs showed enhanced wettability compared to the unmodified PVC, with water contact angles ranging from 42 degrees to 38 degrees. The root mean square (Rq) roughness of the PEMs ranged from 64.5 nm to 74.1 nm, while the unmodified PVC surface displayed a relatively smooth surface with a roughness of 5.4 nm. Stability tests demonstrated that the PEMs maintained their integrity in phosphate buffer (pH 7.4) over seven days at 37 degrees C. The obtained PEMs were not toxic to human fibroblasts and human erythrocytes. The Live/Dead antimicrobial assay results indicated that the PEMs possessed biocidal activity against Pseudomonas aeruginosa (P. aeruginosa) and antiadhesive capacity toward Staphylococcus aureus (S. aureus) and P. aeruginosa after 24 h of incubation. Cytocompatible and antimicrobial tannin-based PEMs on modified PVC surfaces can represent a significant advancement in mitigating bacterial infections associated with PVC-based catheters.
This study used the roto-evaporation technique to engineer a 6 mm three-layer polyurethane vascular graft (TVG) that mimics the architecture of human coronary artery native vessels. Two segmented polyurethanes were synthesized using lysine (SPUUK) and ascorbic acid (SPUAA), and the resulting materials were used to create the intima and adventitia layers, respectively. In contrast, the media layer of the TVG was composed of a commercially available polyurethane, Pearlbond 703 EXP. For comparison purposes, single-layer vascular grafts (SVGs) from individual polyurethanes and a polyurethane blend (MVG) were made and tested similarly and evaluated according to the ISO 7198 standard. The TVG exhibited the highest circumferential tensile strength and longitudinal forces compared to single-layer vascular grafts of lower thicknesses made from the same polyurethanes. The TVG also showed higher suture and burst strength values than native vessels. The TVG withstood up to 2087 ± 139 mmHg and exhibited a compliance of 0.15 ± 0.1%/100 mmHg, while SPUUK SVGs showed a compliance of 5.21 ± 1.29%/100 mmHg, akin to coronary arteries but superior to the saphenous vein. An indirect cytocompatibility test using the MDA-MB-231 cell line showed 90 to 100% viability for all polyurethanes, surpassing the minimum 70% threshold needed for biomaterials deemed cytocompatibility. Despite the non-cytotoxic nature of the polyurethane extracts when grown directly on the surface, they displayed poor fibroblast adhesion, except for SPUUK. All vascular grafts showed hemolysis values under the permissible limit of 5% and longer coagulation times.
Polyetheretherketone (PEEK), a bioinert polymer known for its mechanical properties similar to bone, is capable of averting stress shielding. Due to these attributes, it finds applications in diverse fields like orthopedics, encompassing cervical disc replacement for the neck and spine, along with dentistry and plastic surgery. However, due to insufficient bonding with bone, various methods such as hydroxyapatite (HA) coating on the surface are attempted. Nonetheless, the interface between the polymer and ceramic, two different materials, tended to delaminate after transplantation, posing challenges in preventing implant escape or dislodgement. This research delves into the laser-driven hydroxyapatite penetration-synthesis technique. Differing from conventional coating methods that bond layers of dissimilar materials like HA and PEEK, this technology focuses on synthesizing and infiltrating ionized HA within the PEEK substrate resulting in an interface-free HA-PEEK surface. Conversely, HA-PEEK with this technology applied achieves complete, gap-free direct bone-implant integration. Our research involved the analysis of various aspects. By means of these, we quantitatively assesed the enhanced bone bonding characteristics of HA-PEEK surfaces treated with this approach and offered and explanation for the mechanism responsible for direct bone integration.
Central venous catheters (CVCs) are largely used to administer chemotherapy, hemodialysis, and other treatments. Mostly made of polydimethylsiloxane (PDMS), these medical devices present an intrinsic risk of infection due to the possible formation of biofilm, thus increasing the risk of complications. Drug-releasing polymer coatings are a well-recognized strategy for combating biofilm formation. However, adhesion of the coating to the substrate over time is a major challenge. Therefore, this work aimed to design a chitosan-based coating designed to have maximum adhesion and stability to guarantee sustained drug release and antibacterial properties for at least 14 days. A coating composed of chitosan (CS) as a drug carrier, caffeic acid (CA) and copper sulphate (Cu) as crosslinkers, and moxifloxacin (Mox) as an antibiotic, was deposited through a controlled casting process onto functionalized PDMS surface. PDMS surface modification was investigated by X-ray photoelectron spectroscopy (XPS), and Fourier-transfer infrared (FTIR). Antibiotic release over time was measured in pseudo-physiological conditions (pH 7.4 and at 37 °C). Indirect cytotoxicity assays were performed on human dermal fibroblasts (HDF). The adhesion of the as-designed coating was evaluated by a specially designed pull-off test, before and after aging for 14 days in PBS. XPS and FTIR analyses confirmed the successful PDMS surface modification. The CS-CA-Cu-Mox coating resulted in being non-cytotoxic towards HDF and exhibited sustained moxifloxacin release for up to 49 days. Furthermore, the CS-CA and CS-CA-Cu coatings presented antibacterial activity for 21 days against E. coli, and for 14 days against S. aureus. Importantly, the coating maintained stable adhesion after 14 days in pseudo-physiological conditions. This study provides new insights into the adhesion behavior of polymeric coatings for medical devices, which is rarely reported in the literature.
In the past years, the use of hydrogels derived from decellularized extracellular matrix (dECM) for regenerative medicine purposes has significantly increased. The intrinsic bioactive and immunomodulatory properties indicate these materials as promising candidates for therapeutical applications. However, to date, limitations such as animal-to-animal variability still hinder the clinical translation. Moreover, the choice of tissue source, decellularization and solubilization protocols leads to differences in dECM-derived hydrogels. In this context, detailed characterization of chemical, physical and biological properties of the hydrogels should be performed, with attention to how these properties can be affected by animal-to-animal variability. Herein, we report a detailed characterization of a hydrogel derived from the decellularized extracellular matrix of bovine pericardium (dBP). Protein content, rheological properties, injectability, surface microstructure, in vitro stability and cytocompatibility were evaluated, with particular attention to animal-to-animal variability. The gelation process showed to be thermoresponsive and the obtained dBP hydrogels are injectable, porous, stable up to 2 weeks in aqueous media, rapidly degrading in enzymatic environment and cytocompatible, able to maintain cell viability in human mesenchymal stromal cells. Results from proteomic analysis proved that dBP hydrogels are highly rich in composition, preserving bioactive proteoglycans and glycoproteins in addition to structural proteins such as collagen. With respect to the chemical composition, animal-to-animal variability was shown, but the biological properties were not affected, which remained consistent in different batches. Taken together these results show that dBP hydrogels are excellent candidates for regenerative medicine applications.
Background/Objectives: Medical devices are susceptible to bacterial colonization and biofilm formation, which can result in severe infections, leading to prolonged hospital stays and increased burden on society. Antibacterial films have the potential to assist in preventing biofilm formation, thereby reducing administration of antibiotics and the emergence of antibiotic-resistant strains. In a previous study, a chitosan-based matrix crosslinked with tannic acid and loaded with gentamicin was reported. In this study, five different antibiotics (moxifloxacin, ciprofloxacin, trimethoprim, sulfamethoxazole or linezolid) were loaded into these chitosan-based films, and their impact on the release behavior carefully assessed. Methods: The samples were characterized according to their thickness, swelling, and mass loss in phosphate-buffered saline (PBS), as well as by morphology using scanning electron microscopy (SEM) and optical phase contrast microscopy. Antibiotic release over time was quantified in PBS by high-performance liquid chromatography (HPLC). Antibacterial activity was investigated by disk diffusion test and antibiotic release over time. Finally, the cytotoxicity of the samples was assessed with human dermal fibroblasts. Results: The obtained results differed significantly, especially regarding the antibiotic release time and antibacterial activity, which varied from one day to six months, enabling classification of the films from burst/transient to prolonged release. The films also showed antibacterial features against bacteria mostly present in medical devices and displayed to be non-cytotoxic. Conclusions: In conclusion, it was demonstrated that the antibiotics structure significantly alters the release kinetics, and that by carefully selecting the antibiotic, the consequent release can be tuned. This approach yielded films that could be used for potentially-scalable release in antimicrobial coatings specific to medical devices, aiming to reduce biomaterial associated infections (BAIs).
Aim: Since decades, decellularized extracellular matrix (dECM)-derived materials have received worldwide attention as promising biomaterials for tissue engineering and biomedical applications. Soluble dECM is a versatile raw material that can be easily engineered into the desired shapes and structures. However, there are still some limitations restricting its use, including low hydrophilicity and smooth surfaces, which negatively influence cell adhesion/spreading. The objective of the present study was to investigate surface modification by nitrogen/hydrogen (N2/H2) low-pressure cold plasma treatment as a potential technique to improve the biological response of bovine pericardium dECM films. Methods: Bovine pericardium dECM was enzymatically digested and lyophilized prior to the preparation of thin films via solvent-casting method. Changes in surface properties after plasma treatment were investigated using water contact angle (WCA) and X-ray photoelectron spectroscopy (XPS) measurements. Immunofluorescence staining and resazurin assay for human dermal fibroblasts (HDFs) cultured on the dECM films were used to assess the bioactivity of dECM films. Finally, the hemocompatibility of the films was investigated via clotting time and hemolysis assay. Results: WCA and XPS results revealed that oxygen (O)- and N-containing functional groups were incorporated onto the film surface and an increase in hydrophilicity was observed after plasma treatment. In vitro experiments showed that cell adhesion in plasma-treated dECM films is much faster if compared to the untreated controls. Moreover, the fibroblast proliferation increased after plasma surface modifications. Finally, the hemocompatibility analysis results indicated a delayed blood clotting and no hemolytic effects for all the tested samples. Conclusions: These findings confirmed the potential of dECM as raw material for biocompatible thin films fabrication. Additionally, plasma surface treatment emerged as an eco-friendly and cost-effective strategy to enhance in vitro cell attachment and proliferation on dECM films, expanding their applications in biomedicine.
The fabrication of cell-laden biomimetic scaffolds represents a pillar of tissue engineering and regenerative medicine (TERM) strategies, and collagen is the gold standard matrix for cells to be. In the recent years, extrusion 3D bioprinting introduced new possibilities to increase collagen scaffold performances thanks to the precision, reproducibility, and spatial control. However, the design of pure collagen bioinks represents a challenge, due to the low storage modulus and the long gelation time, which strongly impede the extrusion of a collagen filament and the retention of the desired shape post-printing. In this study, the tannic acid-mediated crosslinking of the outer layer of collagen is proposed as strategy to enable collagen filament extrusion. For this purpose, a tannic acid solution has been used as supporting bath to act exclusively as external crosslinker during the printing process, while allowing the pH- and temperature-driven formation of collagen fibers within the core. Collagen hydrogels (concentration 2-6 mg/mL) were extruded in tannic acid solutions (concentration 5-20 mg/mL). Results proved that external interaction of collagen with tannic acid during 3D printing enables filament extrusion without affecting the bulk properties of the scaffold. The temporary collagen-tannic acid interaction resulted in the formation of a membrane-like external layer that protected the core, where collagen could freely arrange in fibers. The precision of the printed shapes was affected by both tannic acid concentration and needle diameter and can thus be tuned. Altogether, results shown in this study proved that tannic acid bath enables collagen bioprinting, preserves collagen morphology, and allows the manufacture of a cell-laden pure collagen scaffold.
Biodegradable metals represent a valuable solution for the development of temporary vascular implants. These are expected to dissolve in the body over time, avoiding side effects typical of permanent implants, such as thrombosis, in-stent restenosis and chronic inflammation. Iron (Fe)-based alloys, such as iron-manganese (Mn) alloys, are of particular interest for cardiovascular applications due to their intrinsic properties. However, their degradation behavior and biological performance need to be improved. Femtosecond (fs)-laser-induced surface topography could affect both their degradation and cell-material interaction. In this work, fs-laser-induced patterning was performed on a Fe-Mn20 alloy to tune both the degradation behavior of the material and its interaction with the biological environment for cardiovascular applications. Processing parameters were varied to select an optimized surface morphology, characterized by linear grooves. Profilometric analysis, scanning electron microscopy and degradation rate analysis were performed on the treated samples. Thereafter, endothelial cell viability tests and hemocompatibility assessment were carried out on selected process conditions. The obtained fs-laser-induced linear patterns were demonstrated to decrease the degradation rate and to improve the biological response toward both endothelial cells and blood. These results demonstrate how fs-laser-induced patterning is a promising solution for the development of biodegradable metal-based vascular implants.
There is a deep interest in developing new Ni-free Ti-based alloys to replace 316 L stainless steel and Co-Cr alloys for endovascular stent application, mainly because the release of Ni can generate toxicity and allergenicity. Interactions of Ti alloy biomaterials with bone cells and tissues have been widely investigated and reported, while interactions with vascular cells and tissues, such as endothelial cells (ECs) and smooth muscle cells (SMCs), are scarce. Therefore, this study focused on the relationship among the surface finishing features, corrosion behavior and in vitro biological performances regarding human ECs, SMCs and blood of a newly developed Ti-8Mo-2Fe (TMF) alloy, specifically designed for balloon-expandable stent applications. The alloy performances were compared to those of 316 L and pure Ti, prepared with the same surface finishing techniques, which are mechanical polishing and electropolishing. Surface properties were investigated by scanning electron microscopy (SEM), atomic force microscopy (AFM), contact angle (CA) and x-ray photoelectron spectroscopy (XPS). The corrosion behavior was assessed with potentiodynamic polarization (PDP) and electrochemical impedance spectroscopy (EIS) tests in phosphate buffered saline (PBS) solution. No significant differences were observed regarding the corrosion rate measured with PDP analyses, which was of the order of 2 × 10−4 mm/y for all the studied materials. Moreover, similarly to pure Ti, TMF exhibited an advantage over 316 L for biomedical applications, namely remarkable resistance to pitting corrosion up to high potentials. The results evidenced a good cytocompatibility and hemocompatibility, making this group of alloy a potential candidate for cardiovascular implants. In fact, both ECs and SMCs proliferated on TMF surfaces showing a 7-day viability similar to that of pure Ti. Regarding hemocompatibility, TMF did not cause hemolysis, and blood coagulation was delayed on its surface in comparison to pure Ti. When compared to 316 L, TMF showed similar hemocompatibility.
Human tissues are characterized by complex composition and cellular and extracellular matrix (ECM) organization at microscopic level. In most of human tissues, cells and ECM show an anisotropic arrangement, which confers them specific properties.In vitro, the ability to closely mimic this complexity is limited. However, in the last years, extrusion bioprinting showed a certain potential for aligning cells and biomolecules, due to the application of shear stress during the bio-fabrication process. In this work, we propose a strategy to combine collagen (col) with tyramine-modified hyaluronic acid (THA) to obtain a printable col-THA bioink for extrusion bioprinting, solely-based on natural-derived components. Collagen fibers formation within the hybrid hydrogel, as well as collagen distribution and spatial organization before and after printing, were studied. For the validation of the biological outcome, fibroblasts were selected as cellular model and embedded in the col-THA matrix. Cell metabolic activity and cell viability, as well as cell distribution and alignment, were studied in the bioink before and after bioprinting. Results demonstrated successful collagen fibers formation within the bioink, as well as collagen anisotropic alignment along the printing direction. Furthermore, results revealed suitable biological properties, with a slightly reduced metabolic activity at day 1, fully recovered within the first 3 d post-cell embedding. Finally, results showed fibroblasts elongation and alignment along the bioprinting direction. Altogether, results validated the potential to obtain collagen-based bioprinted constructs, with both cellular and ECM anisotropy, without detrimental effects of the fabrication process on the biological outcome. This bioink can be potentially used for a wide range of applications in tissue engineering and regenerative medicine in which anisotropy is required.
Current research on biodegradable iron-based alloys mainly focuses at regulating the material degradation rate, as well as its biological behavior, especially from the point of view of the hemocompatibility and cytocompatibility. In fact, fine-tuning of the surface roughness, morphology and chemical composition can improve the functional response of the material. For that purpose, a surface modification strategy, namely plasma immersion ion implantation (PIII), is proposed to perform the selective modification of surface properties without affecting the bulk ones. In this work, the influence of treatment time (timp = 15, 60 and 120 min.) and implanted species (O, N or C) on the surface properties of a Fe-13Mn-1.2C resorbable alloy was investigated. The findings demonstrated that varying the process gas and the exposition time led to a variety of topographies, surface energies and chemical compositions. XPS analyses and depth profiles clearly showed the impact of the process parameters on the surface features and element distribution, due to implanted species penetration into the alloy. The implanted samples showed a delayed clotting time, thus a better hemocompatibility. In contrast, nitrogen-treated surfaces displayed a more pronounced hemolytic behavior, whereas oxygen and methane did not. PIII implantation appears to be a versatile solution for fine-tuning surface topography, composition and biological properties, making the process promising for the improvement of metallic biodegradable vascular implants.
A previously developed cellularized collagen-based vascular wall model showed promising results in mimicking the biological properties of a native vessel but lacked appropriate mechanical properties. In this work, we aim to improve this collagen-based model by reinforcing it using a tubular polymeric (reinforcement) scaffold. The polymeric reinforcements were fabricated exploiting commercial poly (ε-caprolactone) (PCL), a polymer already used to fabricate other FDA-approved and commercially available devices serving medical applications, through 1) solution electrospinning (SES), 2) 3D printing (3DP) and 3) melt electrowriting (MEW). The non-reinforced cellularized collagen-based model was used as a reference (COL). The effect of the scaffold’s architecture on the resulting mechanical and biological properties of the reinforced collagen-based model were evaluated. SEM imaging showed the differences in scaffolds’ architecture (fiber alignment, fiber diameter and pore size) at both the micro- and the macrolevel. The polymeric scaffold led to significantly improved mechanical properties for the reinforced collagen-based model (initial elastic moduli of 382.05 ± 132.01 kPa, 100.59 ± 31.15 kPa and 245.78 ± 33.54 kPa, respectively for SES, 3DP and MEW at day 7 of maturation) compared to the non-reinforced collagen-based model (16.63 ± 5.69 kPa). Moreover, on day 7, the developed collagen gels showed stresses (for strains between 20% and 55%) in the range of [5–15] kPa for COL, [80–350] kPa for SES, [20–70] kPa for 3DP and [100–190] kPa for MEW. In addition to the effect on the resulting mechanical properties, the polymeric tubes’ architecture influenced cell behavior, in terms of proliferation and attachment, along with collagen gel compaction and extracellular matrix protein expression. The MEW reinforcement resulted in a collagen gel compaction similar to the COL reference, whereas 3DP and SES led to thinner and longer collagen gels. Overall, it can be concluded that 1) the selected processing technique influences the scaffolds’ architecture, which in turn influences the resulting mechanical and biological properties, and 2) the incorporation of a polymeric reinforcement leads to mechanical properties closely matching those of native arteries.
Healthcare-associated infections (HAIs) represent a global burden, leading to significant mortality and generating financial costs. One important cause of HAIs is the microbiological contamination of implantable medical devices. In this context, a novel antimicrobial drug-eluting system, based on chitosan and loaded with gentamicin, a broad-spectrum antibiotic, was developed. The effects of the addition of tannic acid and different FeSO4 concentrations on the loaded antibiotic release were evaluated. The properties of the films were assessed in terms of thickness, swelling, mass loss and wettability. The films’ surface composition was characterized by X-ray photoelectron spectroscopy and Fourier-transform infrared spectroscopy. The antibiotic release in phosphate buffer saline was quantified by high-performance liquid chromatography–mass spectrometry, and the antibacterial activity was evaluated. Hemolysis and cytotoxicity were also assessed. The results showed that the addition of tannic acid and iron decreased the swelling degree and degradation due to strong interactions between the different components, thus impacting gentamicin release for up to 35 days. In conclusion, this study presents a novel strategy to produce low-cost and biocompatible antimicrobial drug-eluting systems with sustained and prolonged antibacterial activity over more than a month.
Zn is considered an excellent candidate material for endovascular applications due to its outstanding combi-nation of biodegradability and biofunctionality. The present work introduces two novel Zn-Ag-Mg alloys with highly desirable mechanical, corrosion, and biological performance. Microstructural characterization revealed a significant grain refinement as a consequence of alloying (Ag) in conjunction with an adequate thermo-mechanical processing route for both alloy systems. Tensile test results indicated that the best mechanical properties in terms of yield strength (YS), ultimate tensile strength (UTS), and elongation to failure (% E) were achieved for the unidirectional rolled (UR) Zn-6Ag-0.5Mg alloy with values of similar to 300 MPa, similar to 370 MPa, and similar to 40%, respectively. However, a superior UTS was exhibited for the Zn-10Ag-0.9Mg alloy with a value of similar to 430 MPa. The observed corrosion rate (CR) trend measured by potentiodynamic polarization test was Zn-6Ag-0.5Mg = 2.232 (mm/year) > Zn-10Ag-0.9Mg = 1.405 (mm/year) > pure Zn = 0.935 (mm/year). When static im-mersion tests were performed, it was observed an unexpected static corrosion rate (SCR) with the following trend: pure Zn = 0.14 (mm/year) > Zn-6Ag-0.5Mg = 0.07 (mm/year) > Zn-10Ag-0.9Mg = 0.05 (mm/year). Moreover, the indirect cell test showed grade 0 of cytotoxicity at 10% and 1% of metal extracts for both ternary alloys. Finally, the proposed alloys possess excellent hemocompatibility characteristics indicating an ideal balance between mechanical integrity and biocompatibility required for the intended application.
Biodegradable metallic alloys are promising materials for the development of temporary medical implants, including cardiovascular and orthopedic devices. The present work explores the surface modification of a biodegradable Fe–20Mn alloy by means of ultrashort laser texturing and the correlation between the laser‐induced surface morphology and the degradation behavior. In detail, the effect of different processing parameters on surface morphology is explored and compared with the unprocessed surface. It is found that laser texturing can tune the degradation rate, selectively inducing positive (+29%) or negative (−31%) change with respect to the untreated surface.
In this featured review manuscript, the aim is to present a critical survey on the processes available for fabricating bioartificial organs (BAOs). The focus will be on hollow tubular organs for the transport of anabolites and catabolites, i.e., vessels, trachea, esophagus, ureter and urethra, and intestine. First, the anatomic hierarchical structures of tubular organs, as well as their principal physiological functions, will be presented, as this constitutes the mandatory requirements for effectively designing and developing physiologically relevant BAOs. Second, 3D bioprinting, solution electrospinning, and melt electrowriting will be introduced, together with their capacity to match the requirements imposed by designing scaffolds compatible with the anatomical and physiologically relevant environment. Finally, the intrinsic correlation between processes, materials, and cells will be critically discussed, and directives defining the strengths, weaknesses, and opportunities offered by each process will be proposed for assisting bioengineers in the selection of the appropriate process for the target BAO and its specific required functions.