The Panchromatic Fourier Transform Spectrometer Engineering Model (PanFTS-EM) instrument is an imaging FTS to meet the requirements of the NASA GEO-CAPE Decadal Survey mission, as well as other missions for atmospheric composition and carbon cycle studies from geostationary orbit. PanFTS-EM is a flight-like engineering model which emulates the critical functions of the PanFTS flight instrument under realistic flight conditions.
The Orbiting Carbon Observatory-2 (OCO-2), launched on 2 July 2014, is a NASA mission designed to measure the column-averaged CO2 dry air mole fraction, XCO2. Towards that goal, it will collect spectra of reflected sunlight in narrow spectral ranges centered at 0.76, 1.6 and 2.0 μm with a resolving power (λ/Δ λ) of 20 000. These spectra will be used in an optimal estimation framework to retrieve XCO2. About 100 000 cloud free soundings of XCO2 each day will allow estimates of net CO2 fluxes on regional to continental scales to be determined. Here, we evaluate the OCO-2 spectrometer performance using pre-launch data acquired during instrument thermal vacuum tests in April 2012. A heliostat and a diffuser plate were used to feed direct sunlight into the OCO-2 instrument and spectra were recorded. These spectra were compared to those collected concurrently from a nearby high-resolution Fourier Transform Spectrometer that was part of the Total Carbon Column Observing Network (TCCON). Using the launch-ready OCO-2 calibration and spectroscopic parameters, we performed total column scaling fits to all spectral bands and compared these to TCCON results. On 20 April, we detected a CO2 plume from the Los Angeles basin at the JPL site with strongly enhanced short-term variability on the order of 1% (3–4 ppm). We also found good (< 0.5 ppm) inter-footprint consistency in retrieved XCO2. The variations in spectral fitting residuals are consistent with signal-to-noise estimates from instrument calibration, while average residuals are systematic and mostly attributable to remaining errors in our knowledge of the CO2 and O2 spectroscopic parameters. A few remaining inconsistencies observed during the tests may be attributable to the specific instrument setup on the ground and will be re-evaluated with in-orbit data.
Inadequate treatment of aerosol scattering can be a significant source of error when retrieving column‐averaged dry‐air mole fractions of CO2 (XCO2) from space‐based measurements of backscattered solar shortwave radiation. We have developed a retrieval algorithm, RemoTeC, that retrieves three aerosol parameters (amount, size, and height) simultaneously with XCO2. Here we evaluate the ability of RemoTeC to account for light path modifications by clouds, subvisual cirrus, and aerosols when retrieving XCO2 from Greenhouse Gases Observing Satellite (GOSAT) Thermal and Near‐infrared Sensor for carbon Observation (TANSO)‐Fourier Transform Spectrometer (FTS) measurements. We first evaluate a cloud filter based on measurements from the Cloud and Aerosol Imager and a cirrus filter that uses radiances measured by TANSO‐FTS in the 2 micron spectral region, with strong water absorption. For the cloud‐screened scenes, we then evaluate errors due to aerosols. We find that RemoTeC is well capable of accounting for scattering by aerosols for values of aerosol optical thickness at 750 nm up to 0.25. While no significant correlation of errors is found with albedo, correlations are found with retrieved aerosol parameters. To further improve the XCO2 accuracy, we propose and evaluate a bias correction scheme.Measurements from 12 ground‐based stations of the Total Carbon Column Observing Network (TCCON) are used as a reference in this study. We show that spatial colocation criteria may be relaxed using additional constraints based on modeled XCO2 gradients, to increase the size and diversity of validation data and provide a more robust evaluation of GOSAT retrievals. Global‐scale validation of satellite data remains challenging and would be improved by increasing TCCON coverage.
Abstract. New observations of the vertically integrated CO2 mixing ratio, ⟨CO2⟩, from ground-based remote sensing show that variations in CO2⟩ are primarily determined by large-scale flux patterns. They therefore provide fundamentally different information than observations made within the boundary layer, which reflect the combined influence of large-scale and local fluxes. Observations of both ⟨CO2⟩ and CO2 concentrations in the free troposphere show that large-scale spatial gradients induce synoptic-scale temporal variations in ⟨CO2⟩ in the Northern Hemisphere midlatitudes through horizontal advection. Rather than obscure the signature of surface fluxes on atmospheric CO2, these synoptic-scale variations provide useful information that can be used to reveal the meridional flux distribution. We estimate the meridional gradient in ⟨CO2⟩ from covariations in ⟨CO2⟩ and potential temperature, θ, a dynamical tracer, on synoptic timescales to evaluate surface flux estimates commonly used in carbon cycle models. We find that simulations using Carnegie Ames Stanford Approach (CASA) biospheric fluxes underestimate both the ⟨CO2⟩ seasonal cycle amplitude throughout the Northern Hemisphere midlatitudes and the meridional gradient during the growing season. Simulations using CASA net ecosystem exchange (NEE) with increased and phase-shifted boreal fluxes better fit the observations. Our simulations suggest that climatological mean CASA fluxes underestimate boreal growing season NEE (between 45–65° N) by ~40%. We describe the implications for this large seasonal exchange on inference of the net Northern Hemisphere terrestrial carbon sink.
We compare two conceptually different methods for determining methane column‐averaged mixing ratios from Greenhouse Gases Observing Satellite (GOSAT) shortwave infrared (SWIR) measurements. These methods account differently for light scattering by aerosol and cirrus. The proxy method retrieves a CO2 column which, in conjunction with prior knowledge on CO2acts as a proxy for scattering effects. The physics‐based method accounts for scattering by retrieving three effective parameters of a scattering layer. Both retrievals are validated on a 19‐month data set using ground‐based at 12 stations of the Total Carbon Column Observing Network (TCCON), showing comparable performance: for the proxy retrieval we find station‐dependent retrieval biases from −0.312% to 0.421% of a standard deviation of 0.22% and a typical precision of 17 ppb. The physics method shows biases between −0.836% and −0.081% with a standard deviation of 0.24% and a precision similar to the proxy method. Complementing this validation we compared both retrievals with simulated methane fields from a global chemistry‐transport model. This identified shortcomings of both retrievals causing biases of up to 1ings and provide a satisfying validation of any methane retrieval from space‐borne SWIR measurements, in our opinion it is essential to further expand the network of TCCON stations.
The Panchromatic Fourier Transform Spectrometer (PanFTS) instrument is being developed, to meet the science demands of measuring a wide range of trace gases with unprecedented vertical resolution, by sensing the UV, visible, and IR in one instrument.
Focal plane arrays (FPAs) with high frame rates and many pixels benefit several upcoming Earth science missions including GEO-CAPE, GACM, and ACE by enabling broader spatial coverage and higher spectral resolution. FPAs for the PanFTS, a high spatial resolution Fourier transform spectrometer and a candidate instrument for the GEO-CAPE mission are the focus of the developments reported here, but this FPA technology has the potential to enable a variety of future measurements and instruments. The ESTO ACT Program funded the developed of a fast readout integrated circuit (ROIC) based on an innovative in-pixel analog-to-digital converter (ADC). The 128 X 128 pixel ROIC features 60 ?m pixels, a 14-bit ADC in each pixel and operates at a continuous frame rate of 14 kHz consuming only 1.1 W of power. The ROIC outputs digitized data completely eliminating the bulky, power consuming signal chains needed by conventional FPAs. The 128 X 128 pixel ROIC has been fabricated in CMOS and tested at the Jet Propulsion Laboratory. The current version is designed to be hybridized with PIN photodiode arrays via indium bump bonding for light detection in the visible and ultraviolet spectral regions. However, the ROIC design incorporates a small photodiode in each cell to permit detailed characterization of the ROICperformance without the need for hybridization. We will describe the essential features of the ROIC design and present results of ROIC performance measurements.
The Panchromatic Fourier Transform Spectrometer (PanFTS) instrument is being developed, to meet the science demands of measuring a wide range of trace gases with unprecedented vertical resolution, by sensing the UV, visible, and IR in one instrument.
The Measurements of Humidity in the Atmosphere and Validation Experiment (MOHAVE) 2009 campaign took place on 11-27 October 2009 at the JPL Table Mountain Facility in California (TMF). The main objectives of the campaign were to (1) validate the water vapor measurements of several instruments, including, three Raman lidars, two microwave radiometers, two Fourier-Transform spectrometers, and two GPS receivers (column water), (2) cover water vapor measurements from the ground to the mesopause without gaps, and (3) study upper tropospheric humidity variability at timescales varying from a few minutes to several days.A total of 58 radiosondes and 20 Frost-Point hygrometer sondes were launched. Two types of radiosondes were used during the campaign. Non negligible differences in the readings between the two radiosonde types used (Vaisala RS92 and InterMet iMet-1) made a small, but measurable impact on the derivation of water vapor mixing ratio by the Frost-Point hygrometers. As observed in previous campaigns, the RS92 humidity measurements remained within 5% of the Frost-point in the lower and mid-troposphere, but were too dry in the upper troposphere.Over 270 h of water vapor measurements from three Raman lidars (JPL and GSFC) were compared to RS92, CFH, and NOAA-FPH. The JPL lidar profiles reached 20 km when integrated all night, and 15 km when integrated for 1 h. Excellent agreement between this lidar and the frost-point hygrometers was found throughout the measurement range, with only a 3% (0.3 ppmv) mean wet bias for the lidar in the upper troposphere and lower stratosphere (UTLS). The other two lidars provided satisfactory results in the lower and mid-troposphere (2-5% wet bias over the range 3-10 km), but suffered from contamination by fluorescence (wet bias ranging from 5 to 50% between 10 km and 15 km), preventing their use as an independent measurement in the UTLS.The comparison between all available stratospheric sounders allowed to identify only the largest biases, in particular a 10% dry bias of the Water Vapor Millimeter-wave Spectrometer compared to the Aura-Microwave Limb Sounder. No other large, or at least statistically significant, biases could be observed.Total Precipitable Water (TPW) measurements from six different co-located instruments were available. Several retrieval groups provided their own TPW retrievals, resulting in the comparison of 10 different datasets. Agreement within 7% (0.7 mm) was found between all datasets. Such good agreement illustrates the maturity of these measurements and raises confidence levels for their use as an alternate or complementary source of calibration for the Raman lidars.Tropospheric and stratospheric ozone and temperature measurements were also available during the campaign. The water vapor and ozone lidar measurements, together with the advected potential vorticity results from the high-resolution transport model MIMOSA, allowed the identification and study of a deep stratospheric intrusion over TMF. These observations demonstrated the lidar strong potential for future long-term monitoring of water vapor in the UTLS.