Accurate identification of local changes in the biomechanical properties of the normal and degenerative meniscus is critical to better understand knee joint osteoarthritis onset and progression. Ex-vivo material characterization is typically performed on specimens obtained from different locations, compromising the tissue's structural integrity and thus altering its mechanical behavior. Therefore, the aim of this in-silico study was to establish a non-invasive method to determine the region-specific material properties of the degenerated human meniscus. In a previous experimental magnetic resonance imaging (MRI) study, the spatial displacement of the meniscus and its root attachments in mildly degenerated (n = 12) and severely degenerated (n = 12) cadaveric knee joints was determined under controlled subject-specific axial joint loading. To simulate the experimental response of the lateral and medial menisci, individual finite element models were created utilizing a transverse isotropic hyper-poroelastic constitutive material formulation. The superficial displacements were applied to the individual models to calculate the femoral reaction force in an inverse finite element analysis. During particle swarm optimization, the four most sensitive material parameters were varied to minimize the error between the femoral reaction force and the force applied in the MRI loading experiment. Individual global and regional parameter sets were identified. In addition to in-depth model verification, prediction errors were determined to quantify the reliability of the identified parameter sets. Both compressibility of the solid meniscus matrix (+141 %, p ≤ 0.04) and hydraulic permeability (+53 %, p ≤ 0.04) were significantly increased in the menisci of severely degenerated knees compared to mildly degenerated knees, irrespective of the meniscus region. By contrast, tensile and shear properties were unaffected by progressive knee joint degeneration. Overall, the optimization procedure resulted in reliable and robust parameter sets, as evidenced by mean prediction errors of <1 %. In conclusion, the proposed approach demonstrated high potential for application in clinical practice, where it might provide a non-invasive diagnostic tool for the early detection of osteoarthritic changes within the knee joint.
Anterolateral rotatory instability (ALRI) may result from isolated ruptures of the anterior cruciate ligament (ACL) or combined lesions with the anterolateral ligament (ALL). Biomechanical studies have demonstrated that the ALL contributes to the overall rotational stability of the knee. The purpose of this study was to investigate the biomechanical function of anatomic ALL reconstruction (ALLrec) in the setting of a combined ACL and ALL injury and reconstruction. The hypothesis was that combined ACL reconstruction (ACLrec) and ALLrec (ACL/ALLrec) significantly reduces internal rotation and shows load sharing between both reconstructions compared with isolated ACLrec. Eight fresh-frozen cadaveric knees were evaluated using a six degrees of freedom knee simulator. Continuous passive motion and external loads were tested. Kinematic differences between ACLrec and combined ACL/ALLrec were compared. Additionally, ACL graft tension and ALL graft strain were measured continuously throughout the testing protocol. Combined anatomic ACL/ALLrec significantly improved the internal rotatory stability compared with isolated ACLrec at 30°–90° under an internal rotation moment. During a static pivot-shift test, additional ALLrec showed no significant reduction of ap-translation. ALLrec resulted in an increase in ACL graft tension during continuous passive motion and with additional internal rotation moment. In the case of a combined ACL and ALL deficiency, concurrent ACLrec and ALLrec significantly improved the rotatory stability of the knee compared with solely reconstructing the ACL at flexion angles ≥ 30°. Nevertheless, additional ALLrec with fixation at 60° and with low tension could not restore extension-near rotatory stability. For that reason, ALLrec with fixation at 60° flexion cannot be recommended in clinical application.
The purpose of this in-vitro study was to examine the kinematics of an artificial, free-floating medial meniscus replacement device under dynamic loading situations and different knee joint states. A dynamic knee simulator was used to perform dynamic loading exercises on three neutrally aligned and three 10° valgus aligned (simulating a medial openwedge high tibial osteotomy - MOWHTO) left human cadaveric knee joints. The knee joints were tested in three states (intact, conventional notchplasty, extended notchplasty) while 11 randomised exercises were simulated (jump landing, squatting, tibial rotation and axial ground impacts at 10°, 30° and 60° knee joint flexion) to investigate the knee joint and implant kinematics by means of rigidly attached reflective marker sets and an according motion analysis. The maximum implant translation relative to the tibial plateau was < 13 mm and the maximum implant rotation was < 19° for all exercises. Both, the notchplasties and the valgus knee alignment did not affect the device kinematics. The results of the present in-vitro study showed that the non-anchored free-floating device remains within the medial knee joint gap under challenging dynamic loading situations without indicating any luxation tendencies. This also provides initial benchtop evidence that the device offers suitable stability and kinematic behaviour to be considered a potential alternative to meniscus allograft transplantation in combination with an MOWHTO, potentially expanding the patient collective in the future.
Abstract Background Knotted and knotless single-anchor reconstruction techniques are frequently performed to reconstruct full-thickness tears of the upper portion of subscapularis tendon. However, it is unclear whether one technique is superior to the other. Questions/purposes (1) When comparing knotless and knotted single-anchor reconstruction techniques in full-thickness tears of the upper subscapularis tendon, is there a difference in stiffness under cyclic load? (2) Are there differences in cyclic gapping between knotless and knotted reconstructions? (3) Are there differences in the maximal stiffness, yield load, and ultimate load to failure? (4) What are the modes of failure of knotless and knotted reconstruction techniques? Methods Eight matched pairs of human cadaveric shoulders were dissected, and a full-thickness tear of the subscapularis tendon (Grade 3 according to the Fox and Romeo classification) was created. The cadavers all were male specimens, with a median (range) age of 69 years (61 to 75). Before biomechanical evaluation, the specimens were randomized into two equal reconstruction groups: knotless single anchor and knotted single anchor. All surgical procedures were performed by a single orthopaedic surgeon who subspecializes in sports orthopedics and shoulder surgery. With a customized set up that was integrated in a dynamic material testing machine, the humeri were consecutively loaded from 10 N to 60 N, from 10 N to 100 N, and from 10 N to 180 N for 50 cycles. Furthermore, the gapping behavior of the tear was analyzed using a video tracking system. Finally, the stiffness, gapping, maximal stiffness, yield loads, and maximum failure loads of both reconstruction groups were statistically analyzed. Failure was defined as retearing of the reconstructed gap threshold due to rupture of the tendon and/or failure of the knots or anchors. After biomechanical testing, bone quality was measured at the footprint of the subscapularis using microCT in all specimens. Bone quality was equal between both groups. To detect a minimum 0.15-mm difference in gap formation between the two repair techniques (with a 5% level of significance; α = 0.05), eight matched pairs (n = 16 in total) were calculated as necessary to achieve a power of at least 90%. Results The first study question can be answered as follows: for stiffness under cyclic load, there were no differences with the numbers available between the knotted and knotless groups at load stages of 10 N to 60 N (32.7 ± 3.5 N/mm versus 34.2 ± 5.6 N/mm, mean difference 1.5 N/mm [95% CI -6.43 to 3.33]; p = 0.55), 10 N to 100 N (45.0 ± 4.8 N/mm versus 45.2 ± 6.0 N/mm, mean difference 0.2 N/mm [95% CI -5.74 to 6.04]; p = 0.95), and 10 N to 180 N (58.2 ± 10.6 N/mm versus 55.2 ± 4.7 N/mm, mean difference 3 N/mm [95% CI -5.84 to 11.79]; p = 0.48). In relation to the second research question, the following results emerged: For cyclic gapping, there were no differences between the knotted and knotless groups at any load levels. The present study was able to show the following with regard to the third research question: Between knotted and knotless repairs, there were no differences in maximal load stiffness (45.3 ± 8.6 N/mm versus 43.5 ± 10.2 N/mm, mean difference 1.8 [95% CI -11.78 to 8.23]; p = 0.71), yield load (425.1 ± 251.4 N versus 379.0 ± 169.4 N, mean difference 46.1 [95% CI -276.02 to 183.72]; p = 0.67), and failure load (521.1 ± 266.2 N versus 475.8 ± 183.3 N, mean difference 45.3 [95% CI -290.42 to 199.79]; p = 0.69). Regarding the fourth question concerning the failure modes, in the knotted repairs, the anchor tore from the bone in 2 of 8, the suture tore from the tendon in 6 of 8, and no suture slipped from the eyelet; in the knotless repairs, the anchor tore from the bone in 2 of 8, the suture tore from the tendon in 3 of 8, and the threads slipped from the eyelet in 3 of 8. Conclusion With the numbers available, we found no differences between single-anchor knotless and knotted reconstruction techniques used to repair full-thickness tears of the upper portion of subscapularis tendon. Clinical Relevance The reconstruction techniques we analyzed showed no differences in terms of their primary stability and biomechanical properties at the time of initial repair and with the numbers available. In view of these experimental results, it would be useful to conduct a clinical study in the future to verify the translationality of the experimental data of the present study.
The aim of this biomechanical in vitro study was to answer the question whether the meniscus acts as a shock absorber in the knee joint or not. The soft tissue of fourteen porcine knee joints was removed, leaving the capsuloligamentous structures intact. The joints were mounted in 45° neutral knee flexion in a previously validated droptower setup. Six joints were exposed to an impact load of 3.54 J, and the resultant loss factor (η) was calculated. Then, the setup was modified to allow sinusoidal loading under dynamic mechanical analysis (DMA) conditions. The remaining eight knee joints were exposed to 10 frequencies ranging from 0.1 to 5 Hz at a static load of 1210 N and a superimposed sinusoidal load of 910 N (2.12 times body weight). Forces (F) and deformation (l) were continuously recorded, and the loss factor (tan δ) was calculated. For both experiments, four meniscus states (intact, medial posterior root avulsion, medial meniscectomy, and total lateral and medial meniscectomy) were investigated. During the droptower experiments, the intact state indicated a loss factor of η = 0.1. Except for the root avulsion state (−15%, p = 0.12), the loss factor decreased (p < 0.046) up to 68% for the total meniscectomy state (p = 0.028) when compared to the intact state. Sinusoidal DMA testing revealed that knees with an intact meniscus had the highest loss factors, ranging from 0.10 to 0.15. Any surgical manipulation lowered the damping ability: Medial meniscectomy resulted in a reduction of 24%, while the resection of both menisci lowered tan δ by 18% compared to the intact state. This biomechanical in vitro study indicates that the shock-absorbing ability of a knee joint is lower when meniscal tissue is resected. In other words, the meniscus contributes to the shock absorption of the knee joint not only during impact loads, but also during sinusoidal loads. The findings may have an impact on the rehabilitation of young, meniscectomized patients who want to return to sports. Consequently, such patients are exposed to critical loads on the articular cartilage, especially when performing sports with recurring impact loads transmitted through the knee joint surfaces.
Synovial joints are covered with hyaline articular cartilage at the bony ends, allowing the transmission of high loads with low friction. Articular cartilage plays a very important mechanical role in our musculoskeletal system by increasing the contact area of the bones, thereby reducing stress. Articular cartilage can degenerate prematurely either idiopathically or due to acquired trauma or congenital joint misalignment, resulting in osteoarthritis, which may require the implantation of a joint replacement. Alternative methods aimed at healing, regenerating, or preventively protecting articular cartilage are currently being studied and tested.
Purpose: Menisci transfer axial loads, while increasing the load-bearing tibiofemoral contact area and decreasing tibiofemoral contact pressure (CP). Numerous clinical and experimental studies agree that an increased CP is one predominant indicator for post-traumatic osteoarthritis (PTOA) of the knee joint. However, due to the immense variability in experimental test setups and wide range of treatment possibilities in meniscus surgery, it is difficult to objectively assess their impact on the CP determination, which is clearly crucial for knee joint health. Therefore, the aim of this systematic review is to investigate the influence of different meniscal injuries and their associated surgical treatments on the CP. Secondly, the influence of different test setups on CP measurements is assessed. On the basis of these results, we established the basis for recommendations for future investigations with the aim to determine CPs under different meniscal states. Methods: This review was conducted in accordance with the PRISMA guidelines. Studies were identified through a systematic literature search in Cochrane, PubMed and Web of Science databases. Literature was searched through pre-defined keywords and medical subject headings. Results: This review indicates a significant increase of up to 235% in peak CP when comparing healthy joints and intact menisci with impaired knee joints, injured or resected menisci. In addition, different test setups were indicated to have major influences on CP: The variety of test setups ranged from standard material testing machines, including customized setups via horizontal and vertical knee joint simulators, through to robotic systems. Differences in applied axial knee joint loads ranged from 0 N up to 2,700 N and resulted unsurprisingly in significantly different peak CPs of between 0.1 and 12.06 MPa. Conclusion: It was shown that untreated traumatic meniscal tears result in an increased CP. Surgical repair intervention were able to restore the CP comparable to the healthy, native condition. Test setup differences and particularly axial joint loading variability also led to major CP differences. In conclusion, when focusing on CP measurements in the knee joint, transparent and traceable in vitro testing conditions are essential to allow researchers to make a direct comparison between future biomechanical investigations.
Purpose: To investigate neuromuscular electromyographic response of the of the upper and lower leg muscles after the application of an intraoperative, isolated mechanical stimulus of the capsuloligamentous structures, including the anterior (ACL) and posterior cruciate ligaments (PCL), lateral (LM) and medial menisci (MM), plica mediopatellaris (PM), and Hoffa’s fat pat (HFP). Methods: The electromyographic response of the upper and lower leg muscles (M. rectus femoris; M. vastus medialis; M. semitendinosus; M. biceps femoris; M. gastrocnemius lateralis) of 15 male patients were measured after an isolated mechanical stimulus of the capsuloligamentous structures during an arthroscopic intervention using a customized intraoperative setup. Target parameters were the short (SLR; <30 milliseconds) and medium latency responses (MLR; >30 milliseconds) after the mechanically-induced trigger. Results: The ACL, PCL, LM, and MM displayed high interindividual reproducibility of >76%. The MM was the only structure indicating both an SLR and MLR for all muscles. Although signals could be detected, there was no reproducibility in electromyographic signal activation for the HFP. The most rapid MLR was observed for the PM (quadriceps: 37 milliseconds). Conclusions: Each stimulated structure displayed an individual MLR response, which allowed us to create neuromapping combining the anatomical and quantitative representations of the individual muscular activation patterns after isolated mechanical stimulation of the capsuloligamentous knee joint structures, corroborating our hypothesis. Level of Evidence: Diagnostic - Level II.
While it is generally accepted that traumatic meniscus pathologies lead to degenerative articular cartilage changes in the mid-to long-term and consecutively to post-traumatic osteoarthritis (PTOA), very little is known about how such injuries initiate tribological changes within the knee and their possible impact on PTOA acceleration. Therefore, the aim of this study was to investigate the influence of three different medial meniscus states (intact, posterior root tear, total meniscectomy) on the initial whole knee joint friction. Six ovine knee joints were tested in a passive pendulum friction testing device under an axial load of 250 N and an initial deflection of 12°, representing swing phase conditions, and under an axial load of 1000 N and an initial deflection of 5°, simulating stance phase conditions. To additionally consider the influence of the time-dependent viscoelastic nature of the knee joint soft tissues on whole joint friction, the tests were performed twice, directly following load application and after 20 min creep loading of either 250 N or 1000 N axial load. On the basis of a three-dimensional joint kinematic analysis, the energy loss during the passive joint motion was analyzed, which allowed considerations on frictional and damping processes within the joint. The so-called "whole knee joint" friction was evaluated using the boundary friction model from Stanton and a viscous friction model from Crisco et al., both analyzing the passive joint flexion-extension motion in the sagittal plane. Significantly lower friction coefficients were observed in the simulated swing phase after meniscectomy (p < 0.05) compared to the intact state. No initial whole joint friction differences between the three meniscus states (p > 0.05) were found under stance phase conditions. Soft tissue creeping significantly increased all the determined friction coefficients (p < 0.05) after resting under load for 20 min. The exponential decay function of the viscous friction model provided a better fit (R2∼0.99) to the decaying flexion-extension data than the linear decay function of the boundary friction model (R2∼0.60). In conclusion, this tribological in vitro study on ovine knee joints indicated that neither a simulated posterior medial meniscus root tear nor the removal of the medial meniscus resulted in an initially increased whole joint friction.
Einleitung Die transorale Intervention beim Larynxkarzinom ist sowohl bei der Laser-Mikrochirurgie (TLM) als auch der transoralen Roboter-assistierten Chirurgie (TORS) aufgrund schwieriger Exposition und Erreichbarkeit laryngealer Strukturen nicht immer möglich. Bei Patienten mit unzureichender Reklination des Kopfes könnte ein nicht-lineares Operationssystem für bessere Visualisierung und Erreichbarkeit sorgen.
Purpose The most common femoral short stems available on the market can, in principle, be divided with regard to their anchoring concepts into a calcar loading and a shortened tapered design. The purpose of this study was to compare the primary stability and stress-shielding of two short stems, which correspond to these two different anchoring concepts. Methods Using seven paired fresh frozen human cadaver femurs, primary axial and rotational stabilities under dynamic load (100–1600 N) were evaluated by miniature displacement transducers after 100,000 load cycles. Changes in cortical strains were measured before and after implantation of both stem types to detect implant-specific load transmission and possible stress-shielding effects. Results Reversible and irreversible micromotions under dynamic load displayed no significant differences between the two implants. Implantation of either stem types resulted in a reduction of cortical strains in the proximal femur, which was less pronounced for the calcar loading implant. Conclusions Both short stems displayed comparable micromotions far below the critical threshold above which osseointegration may disturbed. Neither short stem could avoid proximal stress-shielding. This effect was less pronounced for the calcar loading short stem, which corresponds to a more physiological load transmission.
An exact understanding of the interplay between the articulating tissues of the knee joint in relation to the osteoarthritis (OA)-related degeneration process is of considerable interest. Therefore, the aim of the present study was to characterize the biomechanical properties of mildly and severely degenerated human knee joints, including their menisci and tibial and femoral articular cartilage (AC) surfaces. A spatial biomechanical mapping of the articulating knee joint surfaces of 12 mildly and 12 severely degenerated human cadaveric knee joints was assessed using a multiaxial mechanical testing machine. To do so, indentation stress relaxation tests were combined with thickness and water content measurements at the lateral and medial menisci and the AC of the tibial plateau and femoral condyles to calculate the instantaneous modulus (IM), relaxation modulus, relaxation percentage, maximum applied force during the indentation, and the water content. With progressing joint degeneration, we found an increase in the lateral and the medial meniscal instantaneous moduli ( p < 0.02), relaxation moduli ( p < 0.01), and maximum applied forces ( p < 0.01), while for the underlying tibial AC, the IM ( p = 0.01) and maximum applied force ( p < 0.01) decreased only at the medial compartment. Degeneration had no influence on the relaxation percentage of the soft tissues. While the water content of the menisci did not change with progressing degeneration, the severely degenerated tibial AC contained more water ( p < 0.04) compared to the mildly degenerated tibial cartilage. The results of this study indicate that degeneration-related (bio-)mechanical changes seem likely to be first detectable in the menisci before the articular knee joint cartilage is affected. Should these findings be further reinforced by structural and imaging analyses, the treatment and diagnostic paradigms of OA might be modified, focusing on the early detection of meniscal degeneration and its respective treatment, with the final aim to delay osteoarthritis onset.
Purpose In total hip arthroplasty, uncemented short stems have been used more and more frequently in recent years. Especially for short and curved femoral implants, bone-preserving and soft tissue-sparing properties are postulated. However, indication is limited to sufficient bone quality. At present, there are no curved short stems available which are based on cemented fixation. Methods In this in vitro study, primary stability and maximum fracture load of a newly developed cemented short-stem implant was evaluated in comparison to an already well-established cemented conventional straight stem using six pairs of human cadaver femurs with minor bone quality. Primary stability, including reversible micromotion and irreversible migration, was assessed in a dynamic material-testing machine. Furthermore, a subsequent load-to-failure test revealed the periprosthetic fracture characteristics. Results Reversible and irreversible micromotions showed no statistical difference between the two investigated stems. All short stems fractured under maximum load according to Vancouver type B3, whereas 4 out of 6 conventional stems suffered a periprosthetic fracture according to Vancouver type C. Mean fracture load of the short stems was 3062 N versus 3160 N for the conventional stems (p = 0.84). Conclusion Primary stability of the cemented short stem was not negatively influenced compared to the cemented conventional stem and no significant difference in fracture load was observed. However, a clear difference in the fracture pattern has been identified.
Introduction Transoral intervention in laryngeal carcinoma is not always possible in both laser microsurgery (TLM) and transoral robotic surgery (TORS) due to difficult exposure and accessibility of laryngeal structures. In patients with insufficient cervical spine reclination, a non-linear surgical system could provide better visualization and accessibility.
Background: The anatomic appearance and biomechanical and clinical importance of the anterior meniscus roots are well described. However, little is known about the loads that act on these attachment structures under physiological joint loads and movements. Hypotheses: As compared with uniaxial loading conditions under static knee flexion angles or at very low flexion-extension speeds, more realistic continuous movement simulations in combination with physiological muscle force simulations lead to significantly higher anterior meniscus attachment forces. This increase is even more pronounced in combination with a longitudinal meniscal tear or after total medial meniscectomy. Study Design: Controlled laboratory study. Methods: A validated Oxford Rig–like knee simulator was used to perform a slow squat, a fast squat, and jump landing maneuvers on 9 cadaveric human knee joints, with and without muscle force simulation. The strains in the anterior medial and lateral meniscal periphery and the respective attachments were determined in 3 states: intact meniscus, medial longitudinal tear, and total medial meniscectomy. To determine the attachment forces, a subsequent in situ tensile test was performed. Results: Muscle force simulation resulted in a significant strain increase at the anterior meniscus attachments of up to 308% ( P < .038) and the anterior meniscal periphery of up to 276%. This corresponded to significantly increased forces ( P < .038) acting in the anteromedial attachment with a maximum force of 140 N, as determined during the jump landing simulation. Meniscus attachment strains and forces were significantly influenced ( P = .008) by the longitudinal tear and meniscectomy during the drop jump simulation. Conclusion: Medial and lateral anterior meniscus attachment strains and forces were significantly increased with physiological muscle force simulation, corroborating our hypothesis. Therefore, in vitro tests applying uniaxial loads combined with static knee flexion angles or very low flexion-extension speeds appear to underestimate meniscus attachment forces. Clinical Relevance: The data of the present study might help to optimize the anchoring of meniscal allografts and artificial meniscal substitutes to the tibial plateau. Furthermore, this is the first in vitro study to indicate reasonable minimum stability requirements regarding the reattachment of torn anterior meniscus roots.
Introduction Supplementation with polyphenols of blueberries protect the cognition and have beneficial effects in therapy of cancer, obesity, diabetes and cardiovascular diseases [1]. In addition, several publications report positive effects on bone status in rat osteoporosis models [2], [3]]. Thus, we asked in the present study whether the long-term administration of blueberry polyphenol extract is able to reverse age-related bone alterations in a murine model of aging.
Direct microlaryngoscopy is a frequently performed procedure in otorhinolaryngology, whereby considerable force is exerted on the patients’ teeth, as well as oropharyngeal and laryngeal structures. Especially in cases of a challenging exposure of the anterior commissure, the cervical spine needs to be brought into a hyperextended position, which is not possible in every patient. Therefore, the conflict between the straight rigid microlaryngoscope and the curvature of the oropharyngeal corridor frequently results in tissue trauma with the consequence of teeth fracture, hematoma or nerve injury. We have developed the s-MAC system, a hyper-angulated video laryngoscope with flexible instruments for transoral laryngeal surgery, which so far shows high feasibility in preclinical studies. Due to its curved shape it may exert less force on teeth and supraglottis as conventional direct microlaryngoscopy. We quantified the effects of these two surgical systems using flexible pressure sensors in two different scenarios: a mobile, hyperextended and an immobile cervical spine of the dummy, to simulate a challenging airway. We could demonstrate a 21% (40% with immobilized cervical spine) reduction of the average peak force acting on the maxillary incisors and a 55% (65% with immobilized cervical spine) reduction of the average intraoperative force on the supraglottis. The developed prototype applied therefore significantly less force on upper front teeth and supraglottis as compared to conventional direct microlaryngoscopy – especially in the case of an immobilized cervical spine.
Degenerative changes of menisci contribute to the evolution of osteoarthritis in the knee joint, because they alter the load transmission to the adjacent articular cartilage. Identifying alterations in the strain response of meniscal tissue under compression that are associated with progressive degeneration may uncover links between biomechanical function and meniscal degeneration. Therefore, the goal of this study was to investigate how degeneration effects the three-dimensional (3D; axial, circumferential, radial) strain in different anatomical regions of human menisci (anterior and posterior root attachment; anterior and posterior horn; pars intermedia) under simulated compression. Magnetic resonance imaging (MRI) was performed to acquire image sequences of 12 mild and 12 severe degenerated knee joints under unloaded and loaded (25%, 50% and 100% body weight (BW)) conditions using a customized loading device. Medial and lateral menisci as well as their root attachments were manually segmented. Intensity-based rigid and non-rigid image registration were performed to obtain 3D deformation fields under the respective load levels. Finally, the 3D voxels were transformed into hexahedral finite-element models and direction-dependent local strain distributions were determined. The axial compressive strain in menisci and meniscal root attachments significantly increased on average from 3.1% in mild degenerated joints to 7.3% in severe degenerated knees at 100% BW (p ≤ 0.021). In severe degenerated knee joints, the menisci displayed a mean circumferential strain of 0.45% (mild: 0.35%) and a mean radial strain of 0.41% (mild: 0.37%) at a load level of 100% BW. No significant changes were observed in the circumferential or radial directions between mild and severe degenerated knee joints for all load levels (p > 0.05). In conclusion, high-resolution MRI was successfully combined with image registration to investigate spatial strain distributions of the meniscus and its attachments in response to compression. The results of the current study highlight that the compressive integrity of the meniscus decreases with progressing tissue degeneration, whereas the tensile properties are maintained.
Different alignment types for a better outcome after TKA were described. However, it is not clear how kinematic alignment influences knee joint kinematic. The purpose of this study was to analyze whether adapted tibial cuts in constitutional varus knees affect knee joint kinematics regarding femoral roll-back, varus/valgus angle, and femorotibial rotation. Seven cadaveric knees with constitutional varus alignment were examined in the native state and after implantation of a cruciate retaining (CR)-TKA with 0°, 3° and 6° tibia cuts using an established knee joint simulator. The effects of varus alignment on femorotibial rollback and rotation was determined. In addition, the native knee joint and different tibial cuts in CR-TKA were compared with Student’s t test. Total knee replacement with a 3° and 6° varus tibia cut had the greatest varus deviation to the native knee (mean 1.6° ± 0.09°, respectively); while, knees with a 0° (mean 0.2° ± 0.01°) tibia cut were most similar to the constitutional varus knee joint. The femoral roll-back in the medial compartment was increased in the native knee (5.7–12.5 mm). A 6° varus cut had a restricted translation in the medial compartment (2–3.2 mm). In the lateral compartment, the extensive translation was observed with a 0° varus cut, followed by 3° and 6° and the native knee. All cuts showed significantly different mean values. Only the cuts at 3° and at 6° in the medial compartment and the cuts at 0° and at 3° in the lateral compartment did not differ significantly. In respect to tibiofemoral rotation, 0° and 3° varus cuts across all loads had the least difference to the native knee (3.4°), with a 0° varus cut showing a higher absolute internal rotation of the tibia than the native knee. Changes in knee kinematics of the tibiofemoral rotation showed significantly different mean values. The potentially improved outcome parameters in TKA with adapted tibia cuts in constitutional varus knees cannot be completely explained by the changes to knee kinematics. Mechanical alignment seems to result in more balanced load distribution and kinematics more closely resembling the native knee. From a kinematic point of view, it is not recommended to place the tibia in more than 3° of varus. Biomechanical study.