Nanometric field-effect-transistor (FET) sensors are made on the tip of spear-shaped dual carbon nanoelectrodes derived from carbon deposition inside double-barrel nanopipettes. The easy fabrication route allows deposition of semiconductors or conducting polymers to comprise the transistor channel. A channel from electrodeposited poly pyrrole (PPy) exhibits high sensitivity toward pH changes. This property is exploited by immobilizing hexokinase on PPy nano-FETs to give rise to a selective ATP biosensor. Extracellular pH and ATP gradients are key biochemical constituents in the microenvironment of living cells; we monitor their real-time changes in relation to cancer cells and cardiomyocytes. The highly localized detection is possible because of the high aspect ratio and the spear-like design of the nano-FET probes. The accurately positioned nano-FET sensors can detect concentration gradients in three-dimensional space, identify biochemical properties of a single living cell, and after cell membrane penetration perform intracellular measurements.
Experimental data on dynamic interactions between individual nanoparticles and membrane processes at nanoscale, essential for biomedical applications of nanoparticles, remain scarce due to limitations of imaging techniques. We were able to follow single 200 nm carboxyl-modified particles interacting with identified membrane structures at the rate of 15 s/frame using a scanning ion conductance microscope modified for simultaneous high-speed topographical and fluorescence imaging. The imaging approach demonstrated here opens a new window into the complexity of nanoparticle-cell interactions.
Infarct borderzone (BZ) expansion following myocardial infarction is accompanied by ventricular dilatation, remodeling, and heart failure. We showed that myofibroblasts (MFBs), which are present in the BZ, tend to form functional gap junctions with adjacent cardiomyocytes (CMs) in-vitro and such heterocellular pairing depolarizes CMs, induces discontinuity in conduction, and slows impulse propagation. Connexin-43 (C×43) plays an important role in establishing the electrical coupling, but its involvement in the dynamics of heterocellular pairing has never been investigated in live cells, due to the limit of the nanoscale resolution. We cultured neonatal rat CMs and MFBs as a culture model of BZ and followed the dynamics of contacts formed between these two cell types. We first seeded the CMs (0.5×103 cell /mm2) and, after 24 hrs, we seeded either wild type or C×43-deficient MFBs (0.15×103 cell/mm2). After another 24 hrs, preparations were mounted in a temperature controlled chamber and perfused with HBSS containing 1% serum. The mobility of the BZ was examined at 36°C using Scanning Ion Conductance Microscopy. We collected consecutive images of live-coupled areas (∼15 μm2) at 4 min. per scan over 60-70 min. The images were analysed in randomly selected points on the BZ to extract information on the movement of cell-cell contact points using a Matlab-based software.
Infarct borderzone (BZ) expansion after acute myocardial infarction is accompanied by functional and structural remodeling, ultimately leading to heart failure. We showed that in vitro myofibroblasts (MFBs) can form gap junctions with adjacent cardiomyocytes (CMs) contributing to CM depolarization, impulse propagation slowing and ectopic activity. Connexin43 (Cx43) plays an important role in establishing electrical coupling, but its involvement in the dynamics of heterocellular coupling has never been investigated in live cells, due to the limit of the nanoscale resolution. Scanning Ion Conductance Microscopy (SICM) can be used to overcome this limit. SICM is a non-invasive method capable of resolving the dynamics of live cell-to-cell contact between neonatal rat CMs and MFBs. We collected consecutive topographical images of live coupled areas (~15 μm2) at ~5 min/scan for 1h. Images were analysed by measuring the movement of randomly selected pixels in the contact area using Matlab-based software. We foun...
Pioneers of Medicine Without a Nobel Prize, pp. 127-139 (2014) No AccessChapter 8: WILLIAM KOUWENHOVEN AND PAUL ZOLL: THE INTRODUCTION OF EXTERNAL CARDIAC MASSAGE, DEFIBRILLATORS AND PACEMAKERSMax LabMax Labhttps://doi.org/10.1142/9781783263851_0008Cited by:0 PreviousNext AboutSectionsPDF/EPUB ToolsAdd to favoritesDownload CitationsTrack CitationsRecommend to Library ShareShare onFacebookTwitterLinked InRedditEmail Abstract: The following sections are included: Introduction Some of their Instrumentation A Slant to their Studies — A Cardiac Electromechanical Yin-Yang Mechanical Yin — Mechanically-induced Resuscitation Mechanical Yang — Mechanically-induced Death The Mechanisms behind Kouwenhoven's and Zoll's Work Current State-of-the-Art Implantable Pacemakers and Defibrillators Conclusion References FiguresReferencesRelatedDetails Pioneers of Medicine Without a Nobel PrizeMetrics History PDF download
Aim: To investigate the effect of surface charge of therapeutic nanoparticles on sarcolemmal ionic homeostasis and the initiation of arrhythmias. Materials & methods: Cultured neonatal rat myocytes were exposed to 50 nm-charged polystyrene latex nanoparticles and examined using a combination of hopping probe scanning ion conductance microscopy, optical recording of action potential characteristics and patch clamp. Results: Positively charged, amine-modified polystyrene latex nanoparticles showed cytotoxic effects and induced large-scale damage to cardiomyocyte membranes leading to calcium alternans and cell death. By contrast, negatively charged, carboxyl-modified polystyrene latex nanoparticles (NegNPs) were not overtly cytotoxic but triggered formation of 50-250-nm nanopores in the membrane. Cells exposed to NegNPs revealed pro-arrhythmic events, such as delayed afterdepolarizations, reduction in conduction velocity and pathological increment of action potential duration together with an increase in ionic current throughout the membrane, carried by the nanopores. Conclusion: The utilization of charged nanoparticles is a novel concept for targeting cardiac excitability. However, this unique nanoscopic investigation reveals an altered electrophysiological substrate, which sensitized the heart cells towards arrhythmias.
The quest for nonoptical imaging methods that can surmount light diffraction limits resulted in the development of scanning probe microscopes. However, most of the existing methods are not quite suitable for studying biological samples. The scanning ion conductance microscope (SICM) bridges the gap between the resolution capabilities of atomic force microscope and scanning electron microscope and functional capabilities of conventional light microscope. A nanopipette mounted on a three-axis piezo-actuator, scans a sample of interest and ion current is measured between the pipette tip and the sample. The feedback control system always keeps a certain distance between the sample and the pipette so the pipette never touches the sample. At the same time pipette movement is recorded and this generates a three-dimensional topographical image of the sample surface. SICM represents an alternative to conventional high-resolution microscopy, especially in imaging topography of live biological samples. In addition, the nanopipette probe provides a host of added modalities, for example using the same pipette and feedback control for efficient approach and seal with the cell membrane for ion channel recording. SICM can be combined in one instrument with optical and fluorescent methods and allows drawing structure-function correlations. It can also be used for precise mechanical force measurements as well as vehicle to apply pressure with precision. This can be done on living cells and tissues for prolonged periods of time without them loosing viability. The SICM is a multifunctional instrument, and it is maturing rapidly and will open even more possibilities in the near future.
Current knowledge of the structural changes taking place during clathrin-mediated endocytosis is largely based on electron microscopy images of fixed preparations and x-ray crystallography data of purified proteins. In this paper, we describe a study of clathrin-coated pit dynamics in living cells using ion conductance microscopy to directly image the changes in pit shape, combined with simultaneous confocal microscopy to follow molecule-specific fluorescence. We find that 70% of pits closed with the formation of a protrusion that grew on one side of the pit, covered the entire pit, and then disappeared together with pit-associated clathrin-enhanced green fluorescent protein (EGFP) and actin-binding protein-EGFP (Abp1-EGFP) fluorescence. This was in contrast to conventionally closing pits that closed and cleaved from flat membrane sheets and lacked accompanying Abp1-EGFP fluorescence. Scission of both types of pits was found to be dynamin-2 dependent. This technique now enables direct spatial and temporal correlation between functional molecule-specific fluorescence and structural information to follow key biological processes at cell surfaces.
published online 16 February 2011 J. R. Soc. Interface Gorelik Mitchell, Adrian H. Chester, David Klenerman, Max J. Lab, Yuri E. Korchev, Sian E. Harding and Julia El-Hamamsy, Claire M. F. Potter, Peter Wright, S.H. Sheikh Abdul Kadir, Alexander R. Lyon, Jane A. Michele Miragoli, Alexey Moshkov, Pavel Novak, Andrew Shevchuk, Viacheslav O. Nikolaev, Ismail living cardiovascular cells high-resolution technology for multi-parametric analysis of Scanning ion conductance microscopy: a convergent
The sarcomeric Z-disc defines the lateral borders of the sarcomere and has primarily been seen as a structure important for mechanical stability. This view has changed dramatically within the last one or two decades. A multitude of novel Z-disc proteins and their interacting partners have been identified, which has led to the identification of additional functions and which have now been assigned to this structure. This includes its importance for intracellular signalling, for mechanosensation and mechanotransduction in particular, an emerging importance for protein turnover and autophagy, as well as its molecular links to the t-tubular system and the sarcoplasmic reticulum. Moreover, the discovery of mutations in a wide variety of Z-disc proteins, which lead to perturbations of several of the above-mentioned systems, gives rise to a diverse group of diseases which can be termed Z-discopathies. This paper provides a brief overview of these novel aspects as well as points to future research directions.
Cardiovascular diseases are complex pathologies that include alterations of various cell functions at the levels of intact tissue, single cells and subcellular signalling compartments. Conventional techniques to study these processes are extremely divergent and rely on a combination of individual methods, which usually provide spatially and temporally limited information on single parameters of interest. This review describes scanning ion conductance microscopy (SICM) as a novel versatile technique capable of simultaneously reporting various structural and functional parameters at nanometre resolution in living cardiovascular cells at the level of the whole tissue, single cells and at the subcellular level, to investigate the mechanisms of cardiovascular disease. SICM is a multimodal imaging technology that allows concurrent and dynamic analysis of membrane morphology and various functional parameters (cell volume, membrane potentials, cellular contraction, single ion-channel currents and some parameters of intracellular signalling) in intact living cardiovascular cells and tissues with nanometre resolution at different levels of organization (tissue, cellular and subcellular levels). Using this technique, we showed that at the tissue level, cell orientation in the inner and outer aortic arch distinguishes atheroprone and atheroprotected regions. At the cellular level, heart failure leads to a pronounced loss of T-tubules in cardiac myocytes accompanied by a reduction in Z-groove ratio. We also demonstrated the capability of SICM to measure the entire cell volume as an index of cellular hypertrophy. This method can be further combined with fluorescence to simultaneously measure cardiomyocyte contraction and intracellular calcium transients or to map subcellular localization of membrane receptors coupled to cyclic adenosine monophosphate production. The SICM pipette can be used for patch-clamp recordings of membrane potential and single channel currents. In conclusion, SICM provides a highly informative multimodal imaging platform for functional analysis of the mechanisms of cardiovascular diseases, which should facilitate identification of novel therapeutic strategies.
Intrahepatic cholestasis of pregnancy may be complicated by fetal arrhythmia, fetal hypoxia, preterm labor, and, in severe cases, intrauterine death. The precise etiology of fetal death is not known. However, taurocholate has been demonstrated to cause arrhythmia and abnormal calcium dynamics in cardiomyocytes. To identify the underlying reason for increased susceptibility of fetal cardiomyocytes to arrhythmia, we studied myofibroblasts (MFBs), which appear during structural remodeling of the adult diseased heart. In vitro, they depolarize rat cardiomyocytes via heterocellular gap junctional coupling. Recently, it has been hypothesized that ventricular MFBs might appear in the developing human heart, triggered by physiological fetal hypoxia. However, their presence in the fetal heart (FH) and their proarrhythmogenic effects have not been systematically characterized. Immunohistochemistry demonstrated that ventricular MFBs transiently appear in the human FH during gestation. We established two in vitro models of the maternal heart (MH) and FH, both exposed to increasing doses of taurocholate. The MH model consisted of confluent strands of rat cardiomyocytes, whereas for the FH model, we added cardiac MFBs on top of cardiomyocytes. Taurocholate in the FH model, but not in the MH model, slowed conduction velocity from 19 to 9 cm/s, induced early after depolarizations, and resulted in sustained re-entrant arrhythmias. These arrhythmic events were prevented by ursodeoxycholic acid, which hyperpolarized MFB membrane potential by modulating potassium conductance. Conclusion: These results illustrate that the appearance of MFBs in the FH may contribute to arrhythmias. The above-described mechanism represents a new therapeutic approach for cardiac arrhythmias at the level of MFB. (HEPATOLOGY 2011;)
Effect of Stretch on Conduction and Cx43. Introduction: In disease states such as heart failure, myocardial infarction, and hypertrophy, changes in the expression and location of Connexin43 (Cx43) occur (Cx43 remodeling), and may predispose to arrhythmias. Stretch may be an important stimulus to Cx43 remodeling; however, it has only been investigated in neonatal cell cultures, which have different physiological properties than adult myocytes. We hypothesized that localized stretch in vivo causes Cx43 remodeling, with associated changes in conduction, mediated by the renin–angiotensin system (RAS). Methods and Results: In an open‐chest canine model, a device was used to stretch part of the right ventricle (RV) by 22% for 6 hours. Activation mapping using a 312‐electrode array was performed before and after stretch. Regional stretch did not change longitudinal conduction velocity (post‐stretch vs baseline: 51.5 ± 5.2 vs 55.3 ± 8.1 cm/s, P = 0.24, n = 11), but significantly reduced transverse conduction velocity (28.7 ± 2.5 vs 35.4 ± 5.4 cm/s, P < 0.01). It also reduced total Cx43 expression, by Western blotting, compared with nonstretched RV of the same animal (86.1 ± 32.2 vs 100 ± 19.4%, P < 0.02, n = 11). Cx43 labeling redistributed to the lateral cell borders. Stretch caused a small but significant increase in the proportion of the dephosphorylated form of Cx43 (stretch 9.95 ± 1.4% vs control 8.74 ± 1.2%, P < 0.05). Olmesartan, an angiotensin II blocker, prevented the stretch‐induced changes in Cx43 levels, localization, and conduction. Conclusion: Myocardial stretch in vivo has opposite effects to that in neonatal myocytes in vitro. Stretch in vivo causes conduction changes associated with Cx43 remodeling that are likely caused by local stretch‐induced activation of the RAS. (J Cardiovasc Electrophysiol, Vol. 21, pp. 1276‐1283, November 2010)
The surface of a living cell is a complex three dimensional structure which is critical to the cell's function. Understanding the relationship between cell structure and function is essential to cell physiological research. Yet techniques for real-time imaging of the complex membrane cellular structures and investigation of the membrane functions of intact living cells are limited. Scanning ion conductance microscopy (SICM) is a relatively new form of Scanning Probe Microscopy, which enables non-contact high resolution imaging of living cells under physiological conditions using a fine nanopipette. Here we present major developments in SICM that will allow imaging of even the most complex structures and processes on live cells under physiological and pathophysiological conditions. Our new method is based on changing the way the pipette moves over the surface which now enables us to image the topography of highly complex live samples, such as neuronal networks, with a resolution better than 20 nm. We then go on to show that we can use this method to directly image the changes in cell surface topography during clathrin-mediated endocytosis in real-time.
Nat. Methods 6, 279–281 (2009); published online 1 March 2009; corrected after print 3 September 2009. In the version of this paper originally published, references to previous work on pulse mode SICM should have been included (Mann, S.A. et al. J. Neurosci. Methods 116, 113–117, (2002) and Happel, P.
T-tubular invaginations of the sarcolemma of ventricular cardiomyocytes contain junctional structures functionally coupling L-type calcium channels to the sarcoplasmic reticulum calcium-release channels (the ryanodine receptors), and therefore their configuration controls the gain of calcium-induced calcium release (CICR). Studies primarily in rodent myocardium have shown the importance of T-tubular structures for calcium transient kinetics and have linked T-tubule disruption to delayed CICR. However, there is disagreement as to the nature of T-tubule changes in human heart failure. We studied isolated ventricular myocytes from patients with ischemic heart disease, idiopathic dilated cardiomyopathy, and hypertrophic obstructive cardiomyopathy and determined T-tubule structure with either the fluorescent membrane dye di-8-ANNEPs or the scanning ion conductance microscope (SICM). The SICM uses a scanning pipette to produce a topographic representation of the surface of the live cell by a non-optical method. We have also compared ventricular myocytes from a rat model of chronic heart failure after myocardial infarction. T-tubule loss, shown by both ANNEPs staining and SICM imaging, was pronounced in human myocytes from all etiologies of disease. SICM imaging showed additional changes in surface structure, with flattening and loss of Z-groove definition common to all etiologies. Rat myocytes from the chronic heart failure model also showed both T-tubule and Z-groove loss, as well as increased spark frequency and greater spark amplitude. This study confirms the loss of T-tubules as part of the phenotypic change in the failing human myocyte, but it also shows that this is part of a wider spectrum of alterations in surface morphology.